{"id":840,"date":"2023-12-18T15:04:36","date_gmt":"2023-12-18T07:04:36","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=840"},"modified":"2024-09-05T16:32:14","modified_gmt":"2024-09-05T08:32:14","slug":"standards-related-to-surge-protection-devices","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pl\/blog\/standards-related-to-surge-protection-devices\/","title":{"rendered":"Normy dotycz\u0105ce urz\u0105dze\u0144 przeciwprzepi\u0119ciowych"},"content":{"rendered":"<strong>IEC\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Urz\u0105dzenia przeciwprzepi\u0119ciowe niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 11: Urz\u0105dzenia przeciwprzepi\u0119ciowe pod\u0142\u0105czane do system\u00f3w elektroenergetycznych niskiego napi\u0119cia \u2013 Wymagania i metody bada\u0144<\/strong>\r\n\r\nIEC 61643-11:2011 ma zastosowanie do urz\u0105dze\u0144 do ochrony przeciwprzepi\u0119ciowej przed po\u015brednimi i bezpo\u015brednimi skutkami wy\u0142adowa\u0144 atmosferycznych lub innymi przej\u015bciowymi przepi\u0119ciami. Urz\u0105dzenia te s\u0105 przystosowane do pod\u0142\u0105czenia do pr\u0105du przemiennego 50\/60 Hz. obwody mocy i sprz\u0119t o napi\u0119ciu znamionowym do 1 000 V r.m.s. Ustanawia si\u0119 charakterystyk\u0119 dzia\u0142ania, standardowe metody testowania i oceny. Urz\u0105dzenia te zawieraj\u0105 co najmniej jeden element nieliniowy i s\u0105 przeznaczone do ograniczania przepi\u0119\u0107 i odwracania pr\u0105d\u00f3w udarowych. To pierwsze wydanie IEC61643-11 uniewa\u017cnia i zast\u0119puje drugie wydanie IEC 61643-1 opublikowane w 2005 roku. G\u0142\u00f3wne zmiany w stosunku do drugiego wydania IEC 61643-1 to ca\u0142kowita restrukturyzacja i ulepszenie procedur testowych i sekwencji testowych.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Urz\u0105dzenia przeciwprzepi\u0119ciowe niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 21: Urz\u0105dzenia przeciwprzepi\u0119ciowe przy\u0142\u0105czane do sieci telekomunikacyjnych i sygnalizacyjnych \u2013 Wymagania u\u017cytkowe i metody bada\u0144<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Ograniczniki przepi\u0119\u0107 niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 12: Urz\u0105dzenia przeciwprzepi\u0119ciowe przy\u0142\u0105czane do sieci elektroenergetycznych niskiego napi\u0119cia \u2013 Zasady doboru i stosowania<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>IEC 61643-22:2015\u00a0<\/strong>\r\n<strong>Ograniczniki przepi\u0119\u0107 niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 22: Urz\u0105dzenia przeciwprzepi\u0119ciowe przy\u0142\u0105czane do sieci telekomunikacyjnych i sygnalizacyjnych \u2013 Zasady doboru i stosowania<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Urz\u0105dzenia przeciwprzepi\u0119ciowe niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 31: Wymagania i metody bada\u0144 urz\u0105dze\u0144 SPD do instalacji fotowoltaicznych<\/strong>\r\n\r\nNorma IEC 61643-31:2018 ma zastosowanie do urz\u0105dze\u0144 przeciwprzepi\u0119ciowych (SPD), przeznaczonych do ochrony przed przepi\u0119ciami przed po\u015brednimi i bezpo\u015brednimi skutkami wy\u0142adowa\u0144 atmosferycznych lub innych przej\u015bciowych przepi\u0119\u0107. Urz\u0105dzenia te przeznaczone s\u0105 do pod\u0142\u0105czenia po stronie pr\u0105du sta\u0142ego instalacji fotowoltaicznych o napi\u0119ciu do 1 500 V DC. Urz\u0105dzenia te zawieraj\u0105 co najmniej jeden element nieliniowy i s\u0105 przeznaczone do ograniczania przepi\u0119\u0107 i odwracania pr\u0105d\u00f3w udarowych. Charakterystyki wydajno\u015bci, wymagania bezpiecze\u0144stwa, standardowe metody testowania iustalane s\u0105 oceny. SPD zgodne z t\u0105 norm\u0105 przeznaczone s\u0105 wy\u0142\u0105cznie do monta\u017cu po stronie DC generator\u00f3w fotowoltaicznych i po stronie DC falownik\u00f3w. Urz\u0105dzenia SPD do system\u00f3w fotowoltaicznych z magazynowaniem energii (np. akumulatory, baterie kondensator\u00f3w) nie s\u0105 uwzgl\u0119dnione. Urz\u0105dzenia SPD z oddzielnymi zaciskami wej\u015bciowymi i wyj\u015bciowymi, kt\u00f3re zawieraj\u0105 okre\u015blon\u0105 impedancj\u0119 szeregow\u0105 pomi\u0119dzy tymi zaciskami (tzw. dwuportowe urz\u0105dzenia SPD zgodnie z IEC 61643-11:2011) nie s\u0105 uwzgl\u0119dnione. SPD zgodne z t\u0105 norm\u0105 s\u0105 przeznaczone doby\u0107 trwale po\u0142\u0105czone tam, gdzie pod\u0142\u0105czanie i od\u0142\u0105czanie sta\u0142ych urz\u0105dze\u0144 SPD mo\u017ce by\u0107 wykonane wy\u0142\u0105cznie za pomoc\u0105 narz\u0119dzia. Niniejsza norma nie dotyczy przeno\u015bnych SPD.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Urz\u0105dzenia przeciwprzepi\u0119ciowe niskiego napi\u0119cia \u2013 Cz\u0119\u015b\u0107 32: Urz\u0105dzenia przeciwprzepi\u0119ciowe pod\u0142\u0105czane do pr\u0105du sta\u0142ego strona instalacji fotowoltaicznych \u2013 Zasady doboru i stosowania<\/strong>\r\n\r\nIEC 61643-32:2017 opisuje zasady doboru, instalacji i koordynacji SPD przeznaczonych do stosowania w systemach fotowoltaicznych (PV) do 1 500 V DC i po stronie pr\u0105du przemiennego systemu PV o napi\u0119ciu znamionowym do 1 000 V rms 50\/60 Hz. Instalacja fotowoltaiczna rozci\u0105ga si\u0119 od uk\u0142adu fotowoltaicznego lub zestawu po\u0142\u0105czonych ze sob\u0105 modu\u0142\u00f3w fotowoltaicznych, obejmuj\u0105cych powi\u0105zane okablowanie i urz\u0105dzenia ochronne oraz falownik, a\u017c do punktu pod\u0142\u0105czenia w tablicy rozdzielczej lub punkcie zasilania. Ta cz\u0119\u015b\u0107 normy IEC 61643uwzgl\u0119dnia SPD stosowane w r\u00f3\u017cnych lokalizacjach i w r\u00f3\u017cnych rodzajach system\u00f3w fotowoltaicznych: systemy fotowoltaiczne umieszczone na szczycie budynku. Systemy fotowoltaiczne zlokalizowane na ziemi, podobnie jak elektrownie polowe, charakteryzuj\u0105 si\u0119 uziemieniem wielokrotnym i systemem uziemienia siatkowego. Termin instalacja fotowoltaiczna odnosi si\u0119 do obu rodzaj\u00f3w system\u00f3w fotowoltaicznych. Termin elektrownia fotowoltaiczna jest u\u017cywany wy\u0142\u0105cznie w odniesieniu do rozbudowanych, wielouziemionych system\u00f3w zasilania w wolnym polu, zlokalizowanych na ziemi. Dla instalacji fotowoltaicznych zawieraj\u0105cych akumulatory dodatkowe wymaganiamo\u017ce by\u0107 konieczne.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Wersja z czerwon\u0105 lini\u0105<\/strong>\r\n<strong>Elementy instalacji odgromowej (LPSC) \u2013 Cz\u0119\u015b\u0107 1: Wymagania dotycz\u0105ce element\u00f3w po\u0142\u0105czeniowych<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components.","protected":false},"featured_media":841,"parent":0,"menu_order":157,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-840","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods","txt":"<strong>IEC\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods<\/strong>\r\n\r\nIEC 61643-11:2011 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50\/60 Hz a.c. power circuits, and equipment rated up to 1 000 V r.m.s. Performance characteristics, standard methods for testing and ratings are established. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents. This first edition of IEC 61643-11 cancels and replaces the second edition of IEC 61643-1 published in 2005. The main changes with respect of the second edition of IEC 61643-1 are the complete restructuring and improvement of the test procedures and test sequences.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Low voltage surge protective devices \u2013 Part 21: Surge protective devices connected to telecommunications and signalling networks \u2013 Performance requirements and testing methods<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 12: Surge protective devices connected to low-voltage power systems \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>IEC 61643-22:2015\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 22: Surge protective devices connected to telecommunications and signalling networks \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 31: Requirements and test methods for SPDs for photovoltaic installations<\/strong>\r\n\r\nIEC 61643-31:2018 is applicable to Surge Protective Devices (SPDs), intended for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are designed to be connected to the DC side of photovoltaic installations rated up to 1 500 V DC. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents. Performance characteristics, safety requirements, standard methods for testing and ratings are established.\u00a0 SPDs complying with this standard are exclusively dedicated to be installed on the DC side of photovoltaic generators and the DC side of inverters. SPDs for PV systems with energy storage (e.g. batteries, capacitor banks) are not covered. SPDs with separate input and output terminals that contain specific series impedance between these terminal(s) (so called two-port SPDs according to IEC 61643-11:2011) are not covered. SPDs compliant with this standard are designed to be permanently connected where connection and disconnection of fixed SPDs can only be done using a tool. This standard does not apply to portable SPDs.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 32: Surge protective devices connected to the d.c. side of photovoltaic installations \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-32:2017 describes the principles for selection, installation and coordination of SPDs intended for use in Photovoltaic (PV) systems up to 1 500 V DC and for the AC side of the PV system rated up to 1 000 V rms 50\/60 Hz. The photovoltaic installation extends from a PV array or a set of interconnected PV-modules to include the associated cabling and protective devices and the inverter up to the connection point in the distribution board or the utility supply point. This part of IEC 61643 considers SPDs used in different locations and in different kinds of PV systems:PV systems located on the top of a building. PV systems located on the ground like free field power plants characterized by multiple earthing and a meshed earthing system. The term PV installation is used to refer to both kinds of PV systems. The term PV power plant is only used for extended free-field multi-earthed power systems located on the ground. For PV installations including batteries additional requirements may be necessary.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Redline version<\/strong>\r\n<strong>Lightning protection system components (LPSC) \u2013 Part 1: Requirements for connection components<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog\/840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media\/841"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=840"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog_category?post=840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}