{"id":801,"date":"2023-12-19T16:44:04","date_gmt":"2023-12-19T08:44:04","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=801"},"modified":"2024-09-05T16:34:00","modified_gmt":"2024-09-05T08:34:00","slug":"the-difference-between-lightning-protection-and-surge-protection","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/pl\/blog\/the-difference-between-lightning-protection-and-surge-protection\/","title":{"rendered":"R\u00f3\u017cnica mi\u0119dzy ochron\u0105 odgromow\u0105 a ochron\u0105 przeciwprzepi\u0119ciow\u0105"},"content":{"rendered":"Lightning and surge protection are two elements of an effective electrical protection system.\r\n\r\nLightning is known to be the most significant source of surges\u2014bolts have been recorded to have a million to a billion volts and between 10,000 to 200,000 amps. However, lightning only makes up a portion of all transient events in a facility.\r\n\r\nBecause transients can originate from both external sources (like lightning) and internal sources, facilities ought to have both a lightning protection system and surge protection installed.\r\n\r\n<strong>System ochrony odgromowej<\/strong>\r\n\r\nA lightning protection system protects a structure from a direct lightning strike.\r\n\r\nTo do this, an air terminal (or system of air terminals) is placed in the most probable position to capture the direct strike, based on the structure\u2019s architectural design and roof equipment. The rest of the system is designed to safely convey that electrical energy from the lighting strike to ground as efficiently and safely as possible.\r\n\r\nTo intercept the strike and conduct the high current energy of a lightning strike into the earth, system components include the:\r\n\r\nAir terminal, which is used to intercept the lightning strike.\r\n\r\nDown conductors, providing the most direct path possible to move the electrical energy towards the ground.\r\n\r\nGrounding system, which provides a path for the current to dissipate into the ground and out of harm\u2019s way.\r\n\r\nBonding, meant to reduce the possibility of voltage differences that are a safety risk.\r\n\r\nLightning protection standards ensure how to properly place air terminals, run cable, ground and bond in order to ensure maximum safety in this energy transfer and dissipation.\r\n\r\n<strong>Urz\u0105dzenie przeciwprzepi\u0119ciowe (SPD)<\/strong>\r\n\r\nUrz\u0105dzenie przeciwprzepi\u0119ciowe (SPD) zosta\u0142o zaprojektowane w celu ochrony system\u00f3w elektrycznych i sprz\u0119tu przed przepi\u0119ciami i zdarzeniami przej\u015bciowymi poprzez ograniczenie napi\u0119\u0107 przej\u015bciowych i odwr\u00f3cenie pr\u0105d\u00f3w udarowych.\r\n\r\n<strong>Co powoduje stany nieustalone i przepi\u0119cia?<\/strong>\r\n\r\nLightning is the most spectacular form of an externally generated surge, however, it is estimated that 65% of all transients are generated internally within the facility by the switching of electrical loads such as:\r\n\r\nLightnings\r\n\r\nHeating systems\r\n\r\nMotors\r\n\r\nOther Inductive loads\r\n\r\n<strong>Jak dzia\u0142a SPD?<\/strong>\r\n\r\nIstnieje co najmniej jeden nieliniowy sk\u0142adnik SPD, kt\u00f3ry w r\u00f3\u017cnych warunkach przechodzi mi\u0119dzy stanem wysokiej i niskiej impedancji. Przy normalnym napi\u0119ciu roboczym urz\u0105dzenia SPD maj\u0105 wysok\u0105 impedancj\u0119 i nie wp\u0142ywaj\u0105 na system. Kiedy w obwodzie pojawia si\u0119 przej\u015bciowe napi\u0119cie, SPD przechodzi w stan przewodzenia (lub niskiej impedancji) i kieruje przej\u015bciow\u0105 energi\u0119 i pr\u0105d z powrotem do \u017ar\u00f3d\u0142a lub uziemienia. Ogranicza to lub ogranicza amplitud\u0119 napi\u0119cia do bezpieczniejszego poziomu. potransjent zostanie przekierowany, SPD automatycznie powraca do stanu wysokiej impedancji.\r\n\r\n<strong>Co odr\u00f3\u017cnia te dwa systemy?<\/strong>\r\n\r\nOn a basic level, the lightning protection system protects the facility and structure from direct strikes, while SPDs protect electrical equipment and systems against surges or transients.\r\n\r\nHow the two operate, and the components involved, also vary. Lightning protection system components are always in place and ready to function, while SPDs monitor internal system voltages and spring into action if a transient voltage occurs on the circuit.","protected":false},"featured_media":802,"parent":0,"menu_order":174,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-801","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Lightning and surge protection are two elements of an effective electrical protection system.","txt":"Lightning and surge protection are two elements of an effective electrical protection system.\r\n\r\nLightning is known to be the most significant source of surges\u2014bolts have been recorded to have a million to a billion volts and between 10,000 to 200,000 amps. However, lightning only makes up a portion of all transient events in a facility.\r\n\r\nBecause transients can originate from both external sources (like lightning) and internal sources, facilities ought to have both a lightning protection system and surge protection installed.\r\n\r\n<strong>Lightning Protection System<\/strong>\r\n\r\nA lightning protection system protects a structure from a direct lightning strike.\r\n\r\nTo do this, an air terminal (or system of air terminals) is placed in the most probable position to capture the direct strike, based on the structure\u2019s architectural design and roof equipment. The rest of the system is designed to safely convey that electrical energy from the lighting strike to ground as efficiently and safely as possible.\r\n\r\nTo intercept the strike and conduct the high current energy of a lightning strike into the earth, system components include the:\r\n\r\nAir terminal, which is used to intercept the lightning strike.\r\n\r\nDown conductors, providing the most direct path possible to move the electrical energy towards the ground.\r\n\r\nGrounding system, which provides a path for the current to dissipate into the ground and out of harm\u2019s way.\r\n\r\nBonding, meant to reduce the possibility of voltage differences that are a safety risk.\r\n\r\nLightning protection standards ensure how to properly place air terminals, run cable, ground and bond in order to ensure maximum safety in this energy transfer and dissipation.\r\n\r\n<strong>Surge Protective Device (SPD)<\/strong>\r\n\r\nA surge protective device (SPD) is designed to protect electrical systems and equipment from surge and transient events by limiting transient voltages and diverting surge currents.\r\n\r\n<strong>What causes transients and surges?<\/strong>\r\n\r\nLightning is the most spectacular form of an externally generated surge, however, it is estimated that 65% of all transients are generated internally within the facility by the switching of electrical loads such as:\r\n\r\nLightnings\r\n\r\nHeating systems\r\n\r\nMotors\r\n\r\nOther Inductive loads\r\n\r\n<strong>How does a SPD work?<\/strong>\r\n\r\nThere is at least one non-linear component of the SPD, which under different conditions, transitions between a high and low impedance state. At normal operating voltages, the SPDs are in a high impedance state and do not affect the system. When a transient voltage occurs on the circuit, the SPD moves into a state of conduction (or low impedance) and diverts the transient energy and current back to its source or ground. This limits or clamps the voltage amplitude to a safer level. After the transient is diverted, the SPD automatically resets back to its high impedance state.\r\n\r\n<strong>What Sets the Two Systems Apart?<\/strong>\r\n\r\nOn a basic level, the lightning protection system protects the facility and structure from direct strikes, while SPDs protect electrical equipment and systems against surges or transients.\r\n\r\nHow the two operate, and the components involved, also vary. Lightning protection system components are always in place and ready to function, while SPDs monitor internal system voltages and spring into action if a transient voltage occurs on the circuit."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog\/801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media\/802"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/media?parent=801"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/pl\/wp-json\/wp\/v2\/blog_category?post=801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}