{"id":2250,"date":"2025-11-24T09:00:10","date_gmt":"2025-11-24T01:00:10","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2250"},"modified":"2025-11-19T16:26:00","modified_gmt":"2025-11-19T08:26:00","slug":"40ka-surge-protector-definition-working-principle-and-how-use","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/nl\/blog\/40ka-surge-protector-definition-working-principle-and-how-use\/","title":{"rendered":"40KA overspanningsbeveiliging Definitie, werkingsprincipe en gebruik"},"content":{"rendered":"<div>Dit artikel is geschreven door de fabrikant van overspanningsbeveiliging, wat is een 40KA-overspanningsbeveiliging, waarom u deze nodig heeft, hoe deze werkt, de voordelen ervan en hoe u deze correct kunt gebruiken op het gebied van elektrische veiligheid.<\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-40-4p-type-2-40ka-690v-1000v-ac-surge-protector\/\" rel=\"attachment wp-att-1729\"><img class=\"alignnone size-full wp-image-1729\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40-1000-4P-1.jpg\" alt=\"BR-40 4P Type 2 690V 800V 1000V AC 40kA overspanningsbeveiliging\" width=\"800\" \/><\/a><\/div>\r\n<h2>1. Wat is een 40KA-overspanningsbeveiliging?<\/h2>\r\nA 40KA surge protector is a voltage-limiting surge protector, typically referring to a maximum discharge current surge capacity of 40 kiloamperes per conductor to ground (or line to line). This \"40KA\" designation (usually written as Imax) represents the maximum single lightning current or surge current value that the protector can safely discharge without causing damage to itself.\r\n\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-40-3p-40ka-690v-1000v-type-2-power-surge-protector-device\/\" rel=\"attachment wp-att-1728\"><img class=\"alignnone size-full wp-image-1728\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40-1000-3P-1.jpg\" alt=\"BR-40 3P 40kA 690V 800V 1000V Type 2 Power Surge Protector-apparaat\" width=\"800\" \/><\/a>\r\n<h2>2. Waarom heb je een 40KA-overspanningsbeveiliging nodig?<\/h2>\r\n<div>Een stroomstoot (of elektrische stroomstoot) is een tijdelijk overspannings- of overstroomverschijnsel in een circuit. De belangrijkste bronnen zijn onder meer:<\/div>\r\n<div><\/div>\r\n<div>Directe blikseminslag of ge\u00efnduceerde stroomstoten: Wanneer bliksem inslaat in de buurt van een voedingslijn, veroorzaakt dit extreem hoge spanning en stroom.<\/div>\r\n<div><\/div>\r\n<div>Interne activiteiten op het elektriciteitsnet: Operaties zoals het starten en stoppen van grote apparatuur of het schakelen van condensatorbanken kunnen ook operationele overspanningen in het elektriciteitsnet genereren.<\/div>\r\n<div>Hoewel deze pieken extreem kort duren, is hun energie enorm, genoeg om de isolatie kapot te maken, circuits door te branden, gegevensverlies te veroorzaken en zelfs brand te veroorzaken.<\/div>\r\n<div><\/div>\r\n<div>40KA-overspanningsbeveiligers zijn ontworpen om deze extreem energieke en zeer destructieve overspanningen het hoofd te bieden, en zijn bijzonder geschikt voor gebieden met een gemiddeld tot hoog bliksemrisico en voor belangrijke inkomende stroomverdeelkasten.<\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-40vg-11-type-2-40ka-class-ii-surge-protector\/\" rel=\"attachment wp-att-1758\"><img class=\"alignnone size-full wp-image-1758\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40VG-11.jpg\" alt=\"BR-40VG 1+1 Type 2 40kA Klasse II overspanningsbeveiliging\" width=\"800\" \/><\/a><\/div>\r\n<h2>3. Werkingsprincipe van de 40KA-overspanningsbeveiliging<\/h2>\r\n<div><strong>40KA surge Protector working principle is \"voltage clamping\" and \"energy discharge.\"<\/strong><\/div>\r\n<div>Bewakingsstatus: Wanneer de netspanning normaal is, vertoont de overspanningsbeveiliging een toestand met hoge impedantie, gelijk aan een open circuit, en heeft dit geen invloed op de normale werking van het circuit.<\/div>\r\n<div>Surge Response: If a sudden transient overvoltage happens due to lightning or operation, and the voltage goes past the protector's activation threshold, its internal parts (like varistors or gas discharge tubes) activate almost instantly.<\/div>\r\n<div>Klemmen en ontladen: de beschermer verandert snel in een toestand met lage impedantie. Dit biedt een pad voor de grote stootstroom om snel naar aarde te stromen. Tegelijkertijd houdt het de spanning tussen de lijnen op een veilig niveau, waardoor wordt voorkomen dat gevaarlijke spanning stroomafwaartse apparatuur bereikt.<\/div>\r\n<div>Herstel: Nadat de piek voorbij is, keert de beschermer automatisch terug naar de hoge impedantiestatus en hervat het circuit de normale werking.<\/div>\r\n<div>Het hele proces wordt in korte tijd voltooid, waardoor het gevaar wordt opgelost voordat het de apparatuur bereikt.<\/div>\r\n<h2>4. Waarom kiezen voor een 40KA-overspanningsbeveiligingsapparaat?<\/h2>\r\nChoosing a 40KA SPD means you've opted for a higher level of protection, with the following specific advantages:\r\n<h3>4.1 Krachtige ontladingscapaciteit<\/h3>\r\nDe ontladingscapaciteit van 40KA is voldoende om de meest ernstige spanningspieken veroorzaakt door directe of indirecte blikseminslagen op te vangen, waardoor een solide eerste verdedigingslinie voor het hele elektrische systeem wordt geboden.\r\n<h3>4.2 Langere levensduur en grotere duurzaamheid<\/h3>\r\nEen hogere ontladingscapaciteit betekent dat wanneer een beschermer wordt blootgesteld aan spanningspieken van dezelfde intensiteit, de interne componenten minder spanning ervaren, wat resulteert in langzamere veroudering en een langere levensduur.\r\n<h3>4.3 Brede toepasbaarheid<\/h3>\r\n40KA SPD is geschikt voor verschillende gelegenheden, zoals woongebouwen, commerci\u00eble gebouwen, fabrieken en communicatiebasisstations, en is vooral geschikt als eerstelijnsbescherming voor hoofdverdeelkasten.\r\n<h3>4.4 Biedt ruime beschermingsmarge<\/h3>\r\nZelfs bij onverwachte extreme spanningspieken kan de 40KA-beschermer een bepaalde buffer bieden, waardoor het risico op volledige uitval als gevolg van defecte beschermer wordt verminderd.\r\n<h3>4.5 Vermindert de vervangingsfrequentie en onderhoudskosten<\/h3>\r\nOmdat het duurzamer is, hoeft het niet zo vaak te worden vervangen als beschermers van een lager niveau onder dezelfde onweersomstandigheden, waardoor de onderhoudskosten op de lange termijn worden verlaagd.\r\n<h3>4.6 Uitstekende restspanningscontrole<\/h3>\r\nEen hoogwaardige 40KA SPD kan een grote stroom ontladen terwijl de restspanning op een laag niveau blijft, wat betekent dat de aan het apparaat geleverde spanning lager is en het beveiligingseffect beter is.\r\n<h3>4.7 Voldoet aan hoge ontwerpnormen<\/h3>\r\nVeel belangrijke industri\u00eble en infrastructuurprojecten vereisen het gebruik van hoogwaardige SPD's in hun ontwerpspecificaties, en 40KA is een van de gebruikelijke keuzes.\r\n<h3>4.8 Verbetert de betrouwbaarheid van het gehele beveiligingssysteem<\/h3>\r\nIn een beveiligingssysteem met meerdere niveaus kan een krachtige SPD van het eerste niveau (40KA) het grootste deel van de piekenergie effectief delen, de druk op volgende beveiligingsniveaus verminderen en zo de betrouwbaarheid van het gehele bliksembeveiligingssysteem verbeteren.\r\n\r\n&nbsp;\r\n<h2>5. Hoe gebruik je een 40KA SPD correct?<\/h2>\r\n<div>Een juiste installatie en gebruik zijn cruciaal; anders gaat het beoogde beschermende effect verloren.<\/div>\r\n<div><\/div>\r\n<div>Correct Selection and Classification: A 40kA SPD is typically installed as a Class B primary protection unit in the building's main distribution cabinet. It needs to be used in conjunction with Class C (typically around 20kA) and Class D (fine protection) units to form a layered protection system.<\/div>\r\n<div><\/div>\r\n<div>Kies een geschikte installatielocatie: Deze moet stroomafwaarts van de hoofdstroomonderbreker worden ge\u00efnstalleerd, bij de inlaat van de inkomende lijn.<\/div>\r\n<div><\/div>\r\n<div>Zorg voor een goede verbinding: Verbindingsdraden moeten kort, recht en dik zijn om de ge\u00efnduceerde spanning op de kabels te verminderen. De lengte van aansluitdraden mag in de regel niet meer dan 0,5 meter bedragen.<\/div>\r\n<div><\/div>\r\n<div>Reliable Grounding: The SPD's grounding wire must be connected to a low-impedance grounding busbar, and the grounding resistance must meet specifications (typically \u22644\u03a9 or lower). Grounding is the final path for surge energy discharge; poor grounding is equivalent to protection failure.<\/div>\r\n<div>Back-upbeveiliging: Een geschikte back-upstroomonderbreker (zoals een zekering of luchtstroomonderbreker) moet in serie worden aangesloten v\u00f3\u00f3r de SPD om kortsluiting te voorkomen in geval van een SPD-storing en om het onderhoud en de vervanging van de SPD te vergemakkelijken.<\/div>\r\n<div><\/div>\r\n<div>Regelmatige inspectie en vervanging: De meeste SPD's hebben een statusindicatorvenster. Hun status moet regelmatig worden gecontroleerd. Als het indicatievenster een storing aangeeft (meestal groen voor normaal, rood\/zwart voor storing), of als de SPD een bekende grote blikseminslag heeft meegemaakt, wordt aanbevolen om deze te controleren, zelfs als de indicator normaal lijkt, en deze indien nodig onmiddellijk te vervangen.<\/div>\r\n&nbsp;\r\n<h2>6. Veelgestelde vragen<\/h2>\r\n<strong>Kan een 40KA-overspanningsbeveiliging het stroomverbruik verminderen?<\/strong>\r\n\r\nNee. Overspanningsbeveiligers hebben onder normale omstandigheden een extreem hoge impedantie en de stroom die er doorheen vloeit ligt in het microamp\u00e8rebereik, dus hun stroomverbruik is verwaarloosbaar. Hun ontwerpdoel is om apparatuur te beschermen tegen onmiddellijke hoogspanningspieken, niet om energie te besparen.\r\n\r\n&nbsp;\r\n\r\n<strong>Soorten overspanningsbeveiligers en hun impact op het stroomverbruik<\/strong>\r\n\r\nDe belangrijkste typen zijn spanningsschakelend (zoals gasontladingsbuizen) en spanningsbegrenzend (zoals varistoren). Ze hebben allebei een extreem laag stroomverbruik in de normale stand-bymodus en hebben geen invloed op het energieverbruik van het circuit. De typekeuze is gebaseerd op het beveiligingsniveau en de locatie (bijvoorbeeld schakelaartype voor hoofdverdeelkasten, spanningsbegrenzend type voor onderverdeelkasten).\r\n\r\n&nbsp;\r\n\r\n<strong>What Does \"40KA\" Represent In Surge Protector Specifications?<\/strong>\r\n\r\nIt typically represents the protector's maximum discharge current Imax, which is the maximum peak current the protector can withstand without damage under a standard 8\/20\u03bcs lightning current waveform test. This is a key parameter for measuring its discharge capability and durability.\r\n\r\n&nbsp;\r\n\r\n<strong>Hoe wordt de KA-beoordeling bepaald?<\/strong>\r\n\r\nDe KA-waarde wordt bepaald door berekening of door tabellen op te zoeken op basis van factoren zoals het onweersrisiconiveau van de installatielocatie, het type energiesysteem (TT\/TN\/IT), de gebouwcategorie en het beschermingsniveau. Hogere KA-waarden zijn bijvoorbeeld vereist in gebieden met frequente bliksemactiviteit of bij de hoofdinkomende lijn van hoge gebouwen.\r\n\r\n&nbsp;\r\n\r\n<strong>Kan een overspanningsbeveiliging van 40 Ka elektrostatische ontlading voorkomen?<\/strong>\r\n\r\nHet kan niet direct worden voorkomen. Bij elektrostatische ontlading (ESD) is sprake van extreem hoge spanning maar extreem lage stroom; het energiespectrum en de duur ervan zijn totaal verschillend van bliksemstroompieken. Voor bescherming tegen statische elektriciteit zijn gespecialiseerde ESD-beveiligingsapparaten nodig, waarvan het ontwerp en het werkingsprincipe verschillen van overspanningsbeveiligers die op elektriciteitsleidingen worden gebruikt.\r\n\r\n&nbsp;\r\n<h2>7. Conclusie: waarom een \u200b\u200b40KA-overspanningsbeveiliging een verstandige investering is<\/h2>\r\nDe 40KA overspanningsbeveiliging biedt een robuuste verdediging voor uw eigendommen, gegevens en levens met zijn krachtige drainagemogelijkheden, uitzonderlijke duurzaamheid en betrouwbaarheid.","protected":false},"featured_media":1729,"parent":0,"menu_order":103,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2250","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"This article was written by surge protector manufacturer, what is 40KA surge protector, why you need it, how it works, its advantages, and how to use it correctly in the field of electrical safety.","txt":"<div>This article was written by surge protector manufacturer, what is 40KA surge protector, why you need it, how it works, its advantages, and how to use it correctly in the field of electrical safety.<\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/product\/br-40-4p-type-2-40ka-690v-1000v-ac-surge-protector\/\" rel=\"attachment wp-att-1729\"><img class=\"alignnone size-full wp-image-1729\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40-1000-4P-1.jpg\" alt=\"BR-40 4P Type 2 690V 800V 1000V AC 40kA Surge Protector\" width=\"800\" \/><\/a><\/div>\r\n<h2>1. What Is 40KA Surge Protector?<\/h2>\r\nA 40KA surge protector is a voltage-limiting surge protector, typically referring to a maximum discharge current surge capacity of 40 kiloamperes per conductor to ground (or line to line). This \"40KA\" designation (usually written as Imax) represents the maximum single lightning current or surge current value that the protector can safely discharge without causing damage to itself.\r\n\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-40-3p-40ka-690v-1000v-type-2-power-surge-protector-device\/\" rel=\"attachment wp-att-1728\"><img class=\"alignnone size-full wp-image-1728\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40-1000-3P-1.jpg\" alt=\"BR-40 3P 40kA 690V 800V 1000V Type 2 Power Surge Protector Device\" width=\"800\" \/><\/a>\r\n<h2>2. Why Do You Need A 40KA Surge Protector?<\/h2>\r\n<div>A power surge (or electrical surge) is a momentary overvoltage or overcurrent phenomenon in a circuit. Its main sources include:<\/div>\r\n<div><\/div>\r\n<div>Direct lightning strikes or induced surges: When lightning strikes near a power supply line, it induces extremely high voltage and current.<\/div>\r\n<div><\/div>\r\n<div>Internal power grid operations: Operations such as starting and stopping large equipment or switching capacitor banks can also generate operational overvoltages in the power grid.<\/div>\r\n<div>Although these surges are extremely short in duration, their energy is enormous, enough to break down insulation, burn out circuits, cause data loss, and even start a fire.<\/div>\r\n<div><\/div>\r\n<div>40KA surge protectors are designed to cope with these extremely high-energy and highly destructive surges, and are particularly suitable for areas with medium to high lightning risk and for important incoming power distribution cabinets.<\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/product\/br-40vg-11-type-2-40ka-class-ii-surge-protector\/\" rel=\"attachment wp-att-1758\"><img class=\"alignnone size-full wp-image-1758\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40VG-11.jpg\" alt=\"BR-40VG 1+1 Type 2 40kA Class II Surge Protector\" width=\"800\" \/><\/a><\/div>\r\n<h2>3. 40KA Surge Protector Working Principle<\/h2>\r\n<div><strong>40KA surge Protector working principle is \"voltage clamping\" and \"energy discharge.\"<\/strong><\/div>\r\n<div>Monitoring Status: When the grid voltage is normal, the surge protector presents a high-impedance state, equivalent to an open circuit, and does not affect the normal operation of the circuit.<\/div>\r\n<div>Surge Response: If a sudden transient overvoltage happens due to lightning or operation, and the voltage goes past the protector's activation threshold, its internal parts (like varistors or gas discharge tubes) activate almost instantly.<\/div>\r\n<div>Clamping and Discharge: The protector quickly turns into a low-impedance state. This provides a path for the large surge current to flow rapidly to ground. At the same time, it keeps the voltage between lines at a safe level, stopping dangerous voltage from reaching equipment downstream.<\/div>\r\n<div>Recovery: After the surge has passed, the protector automatically returns to the high-impedance state, and the circuit resumes normal operation.<\/div>\r\n<div>The entire process is completed in a short time, resolving the danger before it reaches equipment.<\/div>\r\n<h2>4. Why Choose 40KA Surge Protection Device?<\/h2>\r\nChoosing a 40KA SPD means you've opted for a higher level of protection, with the following specific advantages:\r\n<h3>4.1 Powerful Discharge Capacity<\/h3>\r\nThe 40KA discharge capacity is sufficient to cope with most severe surges caused by direct or indirect lightning strikes, providing a solid first line of defense for the entire electrical system.\r\n<h3>4.2 Longer Service Life And Greater Durability<\/h3>\r\nHigher discharge capacity means that when a protector is subjected to surges of the same intensity, its internal components experience less stress, resulting in slower aging and a longer lifespan.\r\n<h3>4.3 Wide Applicability<\/h3>\r\n40KA SPD is suitable for various occasions such as residential buildings, commercial buildings, factories, and communication base stations, and is especially suitable as the first-level protection for main distribution boxes.\r\n<h3>4.4 Provides Ample Protection Margin<\/h3>\r\nEven when faced with unexpected extreme surges, the 40KA protector can provide a certain buffer, reducing the risk of complete failure due to protector breakdown.\r\n<h3>4.5 Reduces Replacement Frequency And Maintenance Costs<\/h3>\r\nBecause it is more durable, it does not need to be replaced as frequently as lower-level protectors under the same thunderstorm conditions, thus reducing long-term maintenance costs.\r\n<h3>4.6 Excellent Residual Voltage Control<\/h3>\r\nA high-quality 40KA SPD can discharge a large current while keeping the residual voltage at a low level, which means that the voltage delivered to the device is lower and the protection effect is better.\r\n<h3>4.7 Meets High Design Standards<\/h3>\r\nMany important industrial and infrastructure projects require the use of high-grade SPDs in their design specifications, and 40KA is one of the common choices.\r\n<h3>4.8 Enhances The Reliability Of The Entire Protection System<\/h3>\r\nIn a multi-level protection system, a powerful first-level (40KA) SPD can effectively share most of the surge energy, reduce the pressure on subsequent protection levels, and thus improve the reliability of the entire lightning protection system.\r\n\r\n&nbsp;\r\n<h2>5. How To Use A 40KA SPD Correctly?<\/h2>\r\n<div>Proper installation and use are crucial; otherwise, the intended protective effect will be lost.<\/div>\r\n<div><\/div>\r\n<div>Correct Selection and Classification: A 40kA SPD is typically installed as a Class B primary protection unit in the building's main distribution cabinet. It needs to be used in conjunction with Class C (typically around 20kA) and Class D (fine protection) units to form a layered protection system.<\/div>\r\n<div><\/div>\r\n<div>Choose a Suitable Installation Location: It should be installed downstream of the main circuit breaker, at the incoming line inlet.<\/div>\r\n<div><\/div>\r\n<div>Ensure a Good Connection: Connecting wires should be short, straight, and thick to reduce induced voltage on the leads. The length of connecting wires is generally required to be no more than 0.5 meters.<\/div>\r\n<div><\/div>\r\n<div>Reliable Grounding: The SPD's grounding wire must be connected to a low-impedance grounding busbar, and the grounding resistance must meet specifications (typically \u22644\u03a9 or lower). Grounding is the final path for surge energy discharge; poor grounding is equivalent to protection failure.<\/div>\r\n<div>Backup Protection: A suitable backup circuit breaker (such as a fuse or air circuit breaker) must be connected in series before the SPD to prevent short circuits in case of SPD failure and to facilitate SPD maintenance and replacement.<\/div>\r\n<div><\/div>\r\n<div>Regular Inspection and Replacement: Most SPDs have a status indicator window. Their status should be checked regularly. If the indicator window shows failure (usually green for normal, red\/black for failure), or if the SPD has experienced a known major lightning strike, it is recommended to check it even if the indicator appears normal, and replace it immediately if necessary.<\/div>\r\n&nbsp;\r\n<h2>6. FAQ<\/h2>\r\n<strong>Can 40KA Surge Protector Reduce Power Consumption?<\/strong>\r\n\r\nNo. Surge protectors have extremely high impedance under normal conditions, and the current flowing through them is in the microamp range, so their power consumption is negligible. Their design purpose is to protect equipment from instantaneous high-voltage surges, not to save energy.\r\n\r\n&nbsp;\r\n\r\n<strong>Types Of Surge Protectors And Their Impact On Power Consumption<\/strong>\r\n\r\nThe main types are voltage-switching (such as gas discharge tubes) and voltage-limiting (such as varistors). They both have extremely low power consumption in normal standby mode and do not affect circuit energy consumption. The type selection is based on protection level and location (e.g., switch type for main distribution boxes, voltage-limiting type for sub-distribution boxes).\r\n\r\n&nbsp;\r\n\r\n<strong>What Does \"40KA\" Represent In Surge Protector Specifications?<\/strong>\r\n\r\nIt typically represents the protector's maximum discharge current Imax, which is the maximum peak current the protector can withstand without damage under a standard 8\/20\u03bcs lightning current waveform test. This is a key parameter for measuring its discharge capability and durability.\r\n\r\n&nbsp;\r\n\r\n<strong>How Is The KA Rating Determined?<\/strong>\r\n\r\nThe KA rating is determined by calculation or by looking up tables based on factors such as the thunderstorm risk level of the installation location, the power system type (TT\/TN\/IT), the building category, and the protection level. For example, higher KA values \u200b\u200bare required in areas with frequent lightning activity or at the main incoming line of high-rise buildings.\r\n\r\n&nbsp;\r\n\r\n<strong>Can A 40Ka Surge Protector Prevent Electrostatic Discharge?<\/strong>\r\n\r\nIt cannot be directly prevented. Electrostatic discharge (ESD) involves extremely high voltage but extremely low current; its energy spectrum and duration are completely different from lightning current surges. Protecting against static electricity requires specialized ESD protection devices, whose design and operating principle differ from surge protectors used on power lines.\r\n\r\n&nbsp;\r\n<h2>7. Conclusion: Why 40KA Surge Protector Is A Wise Investment<\/h2>\r\nThe 40KA Surge Protector provides a robust defense for your property, data, and lives with its powerful drainage capabilities, exceptional durability, and reliability."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog\/2250","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media\/1729"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media?parent=2250"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog_category?post=2250"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}