{"id":2249,"date":"2025-11-21T09:14:19","date_gmt":"2025-11-21T01:14:19","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2249"},"modified":"2025-11-19T15:42:39","modified_gmt":"2025-11-19T07:42:39","slug":"how-to-select-appropriate-ka-rating-for-ac-surge-protection-device","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/nl\/blog\/how-to-select-appropriate-ka-rating-for-ac-surge-protection-device\/","title":{"rendered":"Hoe u de juiste Ka-waarde selecteert voor een AC-overspanningsbeveiligingsapparaat"},"content":{"rendered":"<div>Nu de markt overspoeld wordt met overspanningsbeveiligers vari\u00ebrend van 10KA en 40KA Type 2 SPD's tot zelfs 200KA, kan het kiezen van het juiste model verwarrend zijn.<\/div>\r\n<div><\/div>\r\n<div>Deze uitgebreide gids zal de mysteries van kA ontrafelen en u in staat stellen het perfecte te selecteren <a href=\"https:\/\/www.britecelectric.com\/nl\/product-category\/ac-power-surge-protection\/\">AC-overspanningsbeveiliging<\/a> voor uw toepassing.<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" rel=\"attachment wp-att-1616\"><img class=\"alignnone size-full wp-image-1616\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-1.jpg\" alt=\"BR-25M 1+1 Type 1 25kA overspanningsafleider voor TT en TNS\" width=\"800\" \/><\/a><\/div>\r\n<h2>Begrijp de kA-waarde van overspanningsbeveiligers<\/h2>\r\n<div>De kA-waarde van een overspanningsbeveiliging geeft het vermogen aan om piekenergie van uw apparatuur te absorberen en te omzeilen. Deze wordt gemeten in kiloamp\u00e8re (kA) en geeft de maximale stootstroom aan die het apparaat zonder storing kan weerstaan \u200b\u200bbinnen een bepaald aantal cycli.<\/div>\r\n<div><\/div>\r\n<div>You can think of it as the size of a \"bucket\" to catch a sudden downpour of electrical energy. A small bucket (10KA surge protector) might be sufficient for a light rain, but a torrential downpour requires a much larger bucket (80KA surge protector or higher).<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2>Hoe u de juiste KA-waarde selecteert voor een AC-overspanningsbeveiligingsapparaat<\/h2>\r\nHet kiezen van de juiste kA is een systematisch proces waarbij risicobeoordeling, installatielocatie en naleving van de regelgeving betrokken zijn.\r\n<h3>Risicobeoordeling<\/h3>\r\n<div>Beoordeel eerst de blootstelling aan overspanningsrisico's van uw omgeving. Belangrijke factoren zijn onder meer:<\/div>\r\n<div><\/div>\r\n<div><strong>Geografische locatie:<\/strong> Bent u gevestigd in een gebied dat gevoelig is voor bliksem (bijvoorbeeld landelijk of bergachtig)?<\/div>\r\n<div><\/div>\r\n<div><strong>Type faciliteiten:<\/strong> Is het een woongebouw, een commercieel kantoorgebouw, een ziekenhuis of een industri\u00eble installatie? Kritieke infrastructuur vereist een hoger beschermingsniveau.<\/div>\r\n<div><\/div>\r\n<div><strong>Afstand tot stroombronnen:<\/strong> Locaties in de buurt van transformatoren of hoogspanningsleidingen zijn gevoeliger voor schakelpieken.<\/div>\r\n<h3>Bepaal de installatielocatie van de SPD<\/h3>\r\nThe installation location of the surge protector (SPD) in your electrical system directly determines the required kA nominal value. This is typically categorized by \"Type\":\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c\/\" rel=\"attachment wp-att-1876\"><img class=\"alignnone size-full wp-image-1876\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-1.jpg\" alt=\"BR-25GR 3P Type 1 25kA overspanningsafleider voor TN-C\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 1 (niveau 1-bescherming):<\/strong> Ge\u00efnstalleerd in de hoofdverdeelkast, waar de stroom het gebouw binnenkomt. Het moet bestand zijn tegen de grootste pieken, zoals directe blikseminslagen. 40KA SPD's, 60KA overspanningsbeveiligers of zelfs 100KA SPD's worden hier vaak gebruikt.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-20-31-type-2-20ka-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1717\"><img class=\"alignnone size-full wp-image-1717\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-31-1.jpg\" alt=\"BR-20 3+1 Type 2 20kA overspanningsbeveiliging voor TT en TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 2 (niveau 2-bescherming):<\/strong> Ge\u00efnstalleerd in de verdeelkast om stroomafwaartse apparatuur te beschermen. Dit is de meest voorkomende vorm van bescherming van het hele gebouw. 40KA Type 2 SPD's zijn een populaire en robuuste keuze in veel toepassingen.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-40dp-31-40ka-compact-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1783\"><img class=\"alignnone size-full wp-image-1783\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40DP-31.jpg\" alt=\"BR-40DP 3+1 40kA compact overspanningsbeveiligingsapparaat voor TT en TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 3 (niveau 3-bescherming):<\/strong> Ge\u00efnstalleerd aan de kant van de apparatuur om een \u200b\u200bgoede bescherming te bieden voor de meest gevoelige apparatuur, zoals servers en medische apparaten. Ze worden doorgaans gebruikt in combinatie met de eerste twee soorten SPD's, met lagere kA-vereisten.\r\n<h3>Controleer en volg de lokale normen en specificaties<\/h3>\r\nCompliance with local electrical codes is crucial. For example, in China, GB 50057 \"Code for Design of Lightning Protection of Buildings\" and GB 50343 \"Technical Code for Lightning Protection of Electronic Information Systems in Buildings\" must be followed. These standards typically specify the minimum kA requirements for SPDs at different installation points based on factors such as building type and thunderstorm day zoning.\r\n<h3><\/h3>\r\n<h3>Uitgebreide besluitvorming en modelselectie<\/h3>\r\n<strong>Hoog risico\/hoofdinlaat:<\/strong> Selecteer een SPD type 1 met een hoge kA, zoals een SPD van 60KA of 100KA.\r\n\r\n<strong>Middelgroot risico\/distributiebox:<\/strong> Selecteer een betrouwbare Type 2 SPD, zoals een 25KA of 40KA Type 2 SPD.\r\n\r\n<strong>Fijne bescherming:<\/strong> Selecteer een Type 3 SPD voor specifieke apparatuur.\r\n\r\n&nbsp;\r\n<h2>Algemene scenario's en kA-selectiegids<\/h2>\r\n<h3>10KA overspanningsbeveiliging<\/h3>\r\nGeschikt voor kleine woningen en appartementen in gebieden met een laag risico, of als niveau 3 bescherming na Type 2.\r\n<h3>20KA overspanningsbeveiliging<\/h3>\r\nDe 20KA-overspanningsbeveiliging kan worden gebruikt voor secundaire bescherming in gewone stadswoningen, kleine winkels en kantoren, waardoor het een kosteneffectieve keuze is.\r\n<h3>40KA SPD<\/h3>\r\nDe 40KA SPD is geschikt voor de standaardconfiguratie voor secundaire bescherming van de meeste commerci\u00eble gebouwen, middelgrote fabrieken en hoge woongebouwen in steden, en biedt uitstekende bescherming.\r\n<h3>60KA overspanningsbeveiliging<\/h3>\r\nToepasbare scenario's: Hoofdverdeelkasten (secundair of gecombineerd type) in gebouwen in gebieden met een matig tot hoog bliksemrisico, of industri\u00eble omgevingen.\r\n<h3>80KA overspanningsbeveiliging<\/h3>\r\nDe 80KA-overspanningsbeveiliging wordt gebruikt in de hoofdverdeelkasten van gebieden met een hoog risico, landelijke gebieden en vrijstaande gebouwen, waardoor een sterkere stroomontladingscapaciteit wordt geboden.\r\n<h3>100KA SPD<\/h3>\r\n100KA SPD wordt gebruikt voor de hoofdingangen van grote industri\u00eble faciliteiten, ziekenhuizen, datacenters of als Type 1-beveiliging voor belangrijke gebouwen.\r\n<h3>200KA overspanningsbeveiliging<\/h3>\r\nGebruikt voor bescherming van de hoofdingangen van onweersbuien, kritieke infrastructuur (zoals luchthavens en chemische fabrieken) en communicatiebasisstations.\r\n<h2>Factoren die de selectie van de kA-waarde be\u00efnvloeden<\/h2>\r\n<strong>Spanningsbeveiligingsniveau (omhoog):<\/strong> Deze parameter weerspiegelt de werkelijke spanning die de apparatuur zal ervaren directer dan de kA-waarde. Zorg er bij het selecteren van een SPD voor dat de Up-waarde lager is dan de nominale spanning van de beschermde apparatuur.\r\n\r\n<strong>Reservestroomonderbreker:<\/strong> Zorg ervoor dat de capaciteit van de stroomonderbreker of zekering die bij de SPD wordt gebruikt, is afgestemd om het circuit veilig te ontkoppelen in het geval van een SPD-storing.\r\n\r\n<strong>Modulestatusindicator:<\/strong> Selecteer een SPD met signalering op afstand of visuele alarmen (zoals kleurveranderingen van vensters) om een \u200b\u200bsnelle statusbeoordeling door onderhoudspersoneel mogelijk te maken.\r\n\r\n&nbsp;\r\n<h2>Veelgestelde vragen:<\/h2>\r\n<strong>Why isn't higher kA always better?<\/strong>\r\n\r\nAn excessively high kA value may lead to a correspondingly high residual voltage (protection level) in the SPD, resulting in insufficient protection for delicate equipment. Furthermore, high kASPD values \u200b\u200bare more expensive and may be larger. The principle of \"sufficient with a margin\" should be followed.\r\n\r\n<strong>What's the difference between\u00a0 10KA Surge Protector and a 40KA Type 2 SPD?<\/strong>\r\n\r\nHet belangrijkste verschil zit hem in de huidige afvoercapaciteit. Een SPD van 40KA Type 2 kan stootstromen absorberen en ontladen die tot vier keer groter zijn dan een overspanningsbeveiliging van 10KA, waardoor een betrouwbaardere bescherming wordt geboden voor grotere, kritischere gebouwen of apparatuur, en doorgaans een langere levensduur heeft.\r\n\r\n<strong>Is de kA-waarde van een SPD voor een enkele modus of de som van alle fasen?<\/strong>\r\n\r\nKA verwijst doorgaans naar single-mode (enkelpolige) werking. Een enkelfasige SPD met een nominaal vermogen van 40 kA betekent bijvoorbeeld dat elk van de L- en N-polen een stroomstoot van 40 kA aankan. Een driefasige SPD van 40 kA betekent dat elk van de L1-, L2-, L3- en N-polen 40 kA aankan.\r\n\r\n<strong>Hoe kan ik vaststellen of mijn SPD is mislukt?<\/strong>\r\n\r\nDe meeste moderne SPD's zijn uitgerust met visuele indicatievensters (meestal groen voor normale werking en rood\/zwart voor storing) of externe alarmcontacten. Het regelmatig controleren van deze indicatoren is een cruciaal onderdeel van het onderhoud.\r\n\r\n<strong>Kan ik de kA-capaciteit vergroten door een nieuwe SPD parallel aan de oude aan te sluiten?<\/strong>\r\n\r\nDit wordt sterk afgeraden. Vanwege kleine verschillen in de kenmerken van de apparaten kunnen ze de stroomstoot niet gelijkmatig verdelen, waardoor een van de apparaten als eerste uitvalt, wat een veiligheidsrisico oplevert. De juiste aanpak is om deze te vervangen door een nieuwe SPD met een hogere kA-capaciteit.\r\n\r\n&nbsp;\r\n<h2>Conclusie<\/h2>\r\n<div>Door middel van een systematische beoordeling, van het begrijpen van het onweersrisico in uw regio tot het bepalen of een SPD moet worden ge\u00efnstalleerd op de hoofdingang (zoals een overspanningsbeveiliging van 80 KA) of in een subverdeelkast (40 KA Type 2 SPD), kunt u weloverwogen beslissingen nemen.<\/div>","protected":false},"featured_media":1616,"parent":0,"menu_order":104,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2249","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"This comprehensive guide will unravel the mysteries of kA and empower you to select the perfect AC surge protection device for your application.","txt":"<div>With a market flooded with surge protectors ranging from 10KA and 40KA Type 2 SPDs to even 200KA, choosing the right model can be confusing.<\/div>\r\n<div><\/div>\r\n<div>This comprehensive guide will unravel the mysteries of kA and empower you to select the perfect <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/\">AC surge protection device<\/a> for your application.<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" rel=\"attachment wp-att-1616\"><img class=\"alignnone size-full wp-image-1616\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-1.jpg\" alt=\"BR-25M 1+1 Type 1 25kA Surge Arrester For TT And TNS\" width=\"800\" \/><\/a><\/div>\r\n<h2>Understand the kA rating of surge protectors<\/h2>\r\n<div>The kA value of a surge protector represents its ability to absorb and bypass surge energy from your equipment. It is measured in kiloamperes (kA) and indicates the maximum surge current the device can withstand without failure within a specified number of cycles.<\/div>\r\n<div><\/div>\r\n<div>You can think of it as the size of a \"bucket\" to catch a sudden downpour of electrical energy. A small bucket (10KA surge protector) might be sufficient for a light rain, but a torrential downpour requires a much larger bucket (80KA surge protector or higher).<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2>How To Select Appropriate KA Rating For AC Surge Protection Device<\/h2>\r\nChoosing the right kA is a systematic process that involves risk assessment, installation location, and regulatory compliance.\r\n<h3>Risk Assessment<\/h3>\r\n<div>First, assess the surge risk exposure of your environment. Key factors include:<\/div>\r\n<div><\/div>\r\n<div><strong>Geographic location:<\/strong> Are you located in a high-lightning-prone area (e.g., rural, mountainous)?<\/div>\r\n<div><\/div>\r\n<div><strong>Facilities type:<\/strong> Is it a residential building, commercial office building, hospital, or industrial plant? Critical infrastructure requires a higher level of protection.<\/div>\r\n<div><\/div>\r\n<div><strong>Distance from power sources:<\/strong> Locations near transformers or power lines are more susceptible to switching surges.<\/div>\r\n<h3>Determine the installation location of the SPD<\/h3>\r\nThe installation location of the surge protector (SPD) in your electrical system directly determines the required kA nominal value. This is typically categorized by \"Type\":\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c\/\" rel=\"attachment wp-att-1876\"><img class=\"alignnone size-full wp-image-1876\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-1.jpg\" alt=\"BR-25GR 3P Type 1 25kA Surge Arrester for TN-C\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 1 (Level 1 Protection):<\/strong> Installed in the main distribution cabinet, where power enters the building. It must be able to withstand the largest surges, such as direct lightning strikes. 40KA SPDs, 60KA surge protectors, or even 100KA SPDs are commonly used here.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-20-31-type-2-20ka-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1717\"><img class=\"alignnone size-full wp-image-1717\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-31-1.jpg\" alt=\"BR-20 3+1 Type 2 20kA Surge Protective Device For TT And TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 2 (Level 2 Protection):<\/strong> Installed in the distribution box to protect downstream equipment. This is the most common type of whole-building protection. 40KA Type 2 SPDs are a popular and robust choice in many applications.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-40dp-31-40ka-compact-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1783\"><img class=\"alignnone size-full wp-image-1783\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40DP-31.jpg\" alt=\"BR-40DP 3+1 40kA Compact Surge Protective Device For TT And TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 3 (Level 3 Protection):<\/strong> Installed at the equipment end to provide fine protection for the most sensitive equipment, such as servers and medical devices. They are typically used in conjunction with the first two types of SPDs, with lower kA requirements.\r\n<h3>Review and comply with local standards and specifications<\/h3>\r\nCompliance with local electrical codes is crucial. For example, in China, GB 50057 \"Code for Design of Lightning Protection of Buildings\" and GB 50343 \"Technical Code for Lightning Protection of Electronic Information Systems in Buildings\" must be followed. These standards typically specify the minimum kA requirements for SPDs at different installation points based on factors such as building type and thunderstorm day zoning.\r\n<h3><\/h3>\r\n<h3>Comprehensive decision-making and model selection<\/h3>\r\n<strong>High-risk\/Main Inlet:<\/strong> Select a high-kA Type 1 SPD, such as a 60KA or 100KA SPD.\r\n\r\n<strong>Medium-risk\/Distribution Box:<\/strong> Select a reliable Type 2 SPD, such as a 25KA or 40KA Type 2 SPD.\r\n\r\n<strong>Fine Protection:<\/strong> Select a Type 3 SPD for specific equipment.\r\n\r\n&nbsp;\r\n<h2>Common Scenarios and kA Selection Guide<\/h2>\r\n<h3>10KA Surge Protector<\/h3>\r\nSuitable for small homes and apartments in low-risk areas, or as a level 3 protection after Type 2.\r\n<h3>20KA Surge Protector<\/h3>\r\nThe 20KA surge protector can be used for secondary protection in ordinary urban residences, small shops, and offices, making it a cost-effective choice.\r\n<h3>40KA SPD<\/h3>\r\nThe 40KA SPD is suitable for the secondary protection standard configuration of most commercial buildings, medium-sized factories, and high-rise residential buildings in cities, providing excellent protection.\r\n<h3>60KA Surge Protector<\/h3>\r\nApplicable scenarios: Main distribution boxes (secondary or combined type) in buildings in areas with moderate to high lightning risk, or industrial environments.\r\n<h3>80KA Surge Protector<\/h3>\r\nThe 80KA surge protector is used in the main distribution boxes of high-risk areas, rural areas, and detached buildings, providing stronger current discharge capacity.\r\n<h3>100KA SPD<\/h3>\r\n100KA SPD is used for the main entrances of large industrial facilities, hospitals, data centers, or as Type 1 protection for important buildings.\r\n<h3>200KA Surge Protector<\/h3>\r\nUsed for protection of the main entrances to thunderstorm areas, critical infrastructure (such as airports and chemical plants), and communication base stations.\r\n<h2>Factors influencing the selection of the kA value<\/h2>\r\n<strong>Voltage Protection Level (Up):<\/strong> This parameter reflects the actual voltage the equipment will experience more directly than the kA value. When selecting an SPD, ensure its Up value is lower than the withstand voltage rating of the protected equipment.\r\n\r\n<strong>Backup Circuit Breaker:<\/strong> Ensure the capacity of the circuit breaker or fuse used with the SPD is matched to safely disconnect the circuit in the event of SPD failure.\r\n\r\n<strong>Module Status Indicator:<\/strong> Select an SPD with remote signaling or visual alarms (such as window color changes) to facilitate quick status assessment by maintenance personnel.\r\n\r\n&nbsp;\r\n<h2>FAQ:<\/h2>\r\n<strong>Why isn't higher kA always better?<\/strong>\r\n\r\nAn excessively high kA value may lead to a correspondingly high residual voltage (protection level) in the SPD, resulting in insufficient protection for delicate equipment. Furthermore, high kASPD values \u200b\u200bare more expensive and may be larger. The principle of \"sufficient with a margin\" should be followed.\r\n\r\n<strong>What's the difference between\u00a0 10KA Surge Protector and a 40KA Type 2 SPD?<\/strong>\r\n\r\nThe main difference lies in the current discharge capacity. A 40KA Type 2 SPD can absorb and discharge surge currents up to 4 times greater than a 10KA surge protector, thus providing more reliable protection for larger, more critical buildings or equipment, and typically has a longer service life.\r\n\r\n<strong>Is the kA rating of an SPD for a single mode or the sum of all phases?<\/strong>\r\n\r\nKA typically refers to single-mode (single-pole) operation. For example, a single-phase SPD nominally rated at 40kA means that each of its L and N poles can handle a surge of 40kA. A three-phase 40kA SPD means that each of its L1, L2, L3, and N poles can handle 40kA.\r\n\r\n<strong>How can I determine if my SPD has failed?<\/strong>\r\n\r\nMost modern SPDs are equipped with visual indicator windows (usually green for normal operation and red\/black for failure) or remote alarm contacts. Regularly checking these indicators is a critical part of maintenance.\r\n\r\n<strong>Can I increase the kA capacity by connecting a new SPD in parallel with the old one?<\/strong>\r\n\r\nThis is strongly discouraged. Due to slight differences in device characteristics, they cannot evenly distribute surge current, which may cause one of them to fail first, creating a safety hazard. The correct approach is to replace it with a new SPD with a higher kA capacity.\r\n\r\n&nbsp;\r\n<h2>Conclusion<\/h2>\r\n<div>Through a systematic assessment, from understanding the thunderstorm risk in your area to determining whether an SPD should be installed at the main inlet (such as an 80KA surge protector) or in a sub-distribution box (40KA Type 2 SPD), you can make informed decisions.<\/div>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog\/2249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media\/1616"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media?parent=2249"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog_category?post=2249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}