{"id":2241,"date":"2025-11-19T14:11:15","date_gmt":"2025-11-19T06:11:15","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2241"},"modified":"2025-11-19T15:12:37","modified_gmt":"2025-11-19T07:12:37","slug":"type-1-surge-protection-device-vs-type-2-spd","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/nl\/blog\/type-1-surge-protection-device-vs-type-2-spd\/","title":{"rendered":"Type 1 overspanningsbeveiligingsapparaat VS Type 2 SPD"},"content":{"rendered":"In modern electrical systems, surge protectors (SPDs) are critical devices for protecting against damage from lightning strikes and switch surges. However, many people are confused by the different types, such as Type 1 and Type 2\u00a0surge protection device.\r\n\r\nWhat Is the difference between Type 1 and Type 2 SPD?This article will provide an in-depth comparison of <a href=\"https:\/\/www.britecelectric.com\/nl\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\"><strong>Overspanningsbeveiligingsapparaat type 1<\/strong><\/a> en Type 2 SPD's om u te helpen de verschillen en toepassingsscenario's te begrijpen en de juiste keuze te maken.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2. Type 1 overspanningsbeveiliging versus Type 2 SPD<\/h2>\r\nSurge protectors (SPDs) are the \"safety valves\" of electrical systems. Type 1 and Type 2 are the two most commonly used SPDs. They each have their own functions and work together to build a complete protection system.\r\n<h2 class=\"wp-block-heading\">2.1 Hoofdfunctie van Type 1 en Type 2 SPD<\/h2>\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P Type 1 25kA bliksembeveiligingsapparaat\" width=\"800\" \/><\/a>\r\n<div><strong>Type 1 SPD (bliksemstroomontladingsapparaat):<\/strong><\/div>\r\n<div>Hoofdfunctie: Biedt bescherming tegen directe blikseminslag of gedeeltelijke bliksemstromen. Meestal geplaatst bij de hoofdingang van een gebouw, biedt het eerste (basis)bescherming.<\/div>\r\n<div>Kerntaak: omgaan met en leiden van grote bliksemstromen om schade aan apparatuur en stroomafwaartse leidingen te voorkomen.<\/div>\r\n<div><\/div>\r\n<div><strong>Type 2 SPD (drukregelapparaat):<\/strong><\/div>\r\n<div>Hoofdfunctie: Wordt gebruikt voor bescherming tegen spanningspieken als gevolg van schakelaarbediening en resterende spanningspieken als gevolg van ge\u00efnduceerde blikseminslagen. Het wordt doorgaans ge\u00efnstalleerd in verdeelkasten (zoals vloerverdeelkasten) en biedt een tweede niveau (tussenbescherming).<\/div>\r\n<div>Kerntaak: Beperkt de restspanning tot een veilig niveau voor eindapparatuur en dient als primaire bescherming voor gevoelige elektronische apparatuur.<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2 class=\"wp-block-heading\">2.2 Belangrijkste testparameters<\/h2>\r\n<div><strong>Type 1 SPD Eenfasig:<\/strong><\/div>\r\n<div>Impulse Current (I&lt;sub&gt;imp&lt;\/sub&gt;): The most critical parameter. It indicates the SPD's ability to withstand a typical lightning current, including peak current (10\/350\u03bcs waveform), charge quantity, and other comprehensive requirements. For example: 25 kA (10\/350\u03bcs).<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-20-3p-type-2-20ka-surge-protective-device-for-tn-c\/\" rel=\"attachment wp-att-1711\"><img class=\"alignnone size-full wp-image-1711\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-3P-1.jpg\" alt=\"BR-20 3P Type 2 20kA overspanningsbeveiligingsapparaat voor TN-C\" width=\"800\" \/><\/a><\/div>\r\n<div><strong>Type 2 SPD:<\/strong><\/div>\r\n<div>Nominale ontlaadstroom (I<sub>n<\/sub>): De kernparameter. Het geeft de standaard teststroom (golfvorm van 8\/20 \u03bcs) aan die de SPD meerdere keren kan weerstaan. Bijvoorbeeld: 20 kA (8\/20\u03bcs).<\/div>\r\n<div>Maximale ontlaadstroom (I<sub>max<\/sub>): Geeft de maximale ontlaadstroom (8\/20\u03bcs golfvorm) aan die de SPD in \u00e9\u00e9n enkele handeling kan weerstaan.<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2 class=\"wp-block-heading\">2.3 Golfvormen testen<\/h2>\r\n10\/350\u03bcs waveform (for Type 1 testing): This waveform simulates some of the current characteristics of a direct lightning strike. Its current rise is slow, but its duration is long, carrying approximately 20 times the energy of the 8\/20\u03bcs waveform, making it extremely destructive.\r\n\r\n8\/20\u03bcs waveform (for Type 2 testing): This waveform simulates induced lightning and switching surges. The current rises quickly, its duration is short, and its energy is relatively small.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.4 Installatielocatie<\/h2>\r\nType 1 lightning surge protection device: Installed in the building's main distribution panel (main incoming line box), located after the electricity meter and before or after the main circuit breaker (depending on product design).\r\n\r\nType 2 SPD: Installed in distribution panels, such as floor distribution boxes or distribution boxes in critical equipment rooms (e.g., data centers, elevator control rooms).\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.5 Relatie van extern overspanningsbeveiligingssysteem<\/h2>\r\nType 1 SPD: Must be installed at the power inlet of buildings equipped with external lightning protection systems (lightning rods, down conductors). This is a mandatory requirement of international standards (such as IEC 62305) because it effectively handles direct lightning current coupled from the down conductor to the power line.\r\n\r\nType 2 SPD: Not directly mandatory with external lightning protection systems. Type 2 SPDs are required to handle induced surges regardless of whether the building has an external lightning protection system.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.6 Co\u00f6rdinatie<\/h2>\r\nType 1 en Type 2 SPD's moeten samenwerken. Er moet een bepaalde lijnafstand tussen de twee worden aangehouden (algemeen aanbevolen ten minste 10 meter), of er moeten ontkoppelingsapparaten (zoals speciale reactoren) worden gebruikt om ervoor te zorgen dat, in het geval van een overspanning, de Type 1 SPD eerst uitschakelt om de meeste energie te dissiperen, en vervolgens de Type 2 SPD uitschakelt om de restspanning tot een lager niveau te beperken. Als de afstand onvoldoende is, kan een grote golf de Type 1 omzeilen en de Type 2 beschadigen.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">Heb ik type 1 of type 2 SPD nodig?<\/h2>\r\nDit is een besluitvormingsproces dat u helpt een keuze te maken:\r\n<h3><strong>Heeft het gebouw een extern overspanningsbeveiligingssysteem?<\/strong><\/h3>\r\nYes: You must install a Type 1 SPD in the main distribution box.\r\n\r\nNo\/Unsure: You can skip Type 1, but installing Type 2 is strongly recommended.\r\n<h3><strong>Overspanningsrisicobeoordeling bij inkomende elektriciteitslijn<\/strong><\/h3>\r\nZelfs zonder een extern bliksembeveiligingssysteem is het risico op blikseminslag groot als uw gebouw zich in een open ruimte, op een heuveltop bevindt of lange bovengrondse elektriciteitsleidingen heeft. Het installeren van een Type 1 SPD kan een hoger beschermingsniveau bieden.\r\n<h3><strong>Bepaal de selectie<\/strong><\/h3>\r\nScenario A (Standard residential building, no external lightning protection): Installing a Type 2 SPD in the main distribution box provides sufficient protection.\r\n\r\nScenario B (Villa\/commercial building with lightning rod): A Type 1 SPD must be installed in the main distribution box, and Type 2 SPDs must be installed in floor distribution boxes or distribution boxes for critical equipment.\r\n\r\nScenario C (Risk compromise): If space or budget is limited, a Type 1+2 combined SPD can be installed in the main distribution box (see FAQ).\r\n<h2 class=\"wp-block-heading\">Concept van graduele (geco\u00f6rdineerde) bescherming<\/h2>\r\n<h3>Waarom is graduele bescherming nodig?<\/h3>\r\nNo single SPD can perfectly handle all types of surges. The concept of tiered protection is:\r\n\r\nType 1 (Level 1): Intercepts and discharges the vast majority of the enormous energy (e.g., 90%) at the inlet.\r\n\r\nType 2 (Level 2): \u200b\u200bFurther limits the residual surge voltage after the first level, bringing it within the equipment's safe range.\r\n\r\nType 3 (Fine Protection): Uses surge strips at the equipment end to provide fine protection for the last mile.\r\n\r\nThis is like a line of defense: the first line weakens the main force, the second line clears the residue, and ensures the safety of the main base (your equipment).\r\n<h3>Typisch gradueel beschermingsschema<\/h3>\r\nA complete solution is as follows:\r\n\r\nLevel I: Main Distribution Box \u2192 Type 1 SPD\r\n\r\nLevel II: Floor Distribution Box \u2192 Type 2 SPD\r\n\r\nLevel III: Equipment Front-End (e.g., sockets) \u2192 Type 3 SPD (surge power strip)\r\n<h2 class=\"wp-block-heading\">Veelgestelde vragen<\/h2>\r\n<strong>Kan ik zowel Type 1 als Type 2 enkelfasige SPD installeren?<\/strong>\r\n\r\nAbsolutely, and it's best practice. Type 1 and Type 2 single phase SPDs work together to provide tiered protection from the inlet to the device.\r\n\r\n<strong>Verschil tussen Type 1+2 Gecombineerde Spd en deze afzonderlijk installeren<\/strong>\r\n<div>Type 1+2 gecombineerde SPD: Een enkel apparaat integreert zowel Type 1- als Type 2-modules. De voordelen zijn onder meer ruimtebesparing en eenvoudige installatie, waardoor het bijzonder geschikt is voor scenario's met beperkte ruimte in de hoofdverdeelkast. Het heeft de co\u00f6rdinatietests doorstaan \u200b\u200bom een \u200b\u200bgoede modulecompatibiliteit te garanderen.<\/div>\r\n<div><\/div>\r\n<div>Afzonderlijke installatie: Biedt maximale flexibiliteit en onderhoudbaarheid. Als een Type 1-module beschadigd is, kan alleen de Type 1-module worden vervangen zonder dat dit gevolgen heeft voor de Type 2-module. Er moet echter voldoende afstand tussen de twee worden gewaarborgd, of er moet een ontkoppelingsinrichting worden gebruikt.<\/div>\r\n<div><\/div>\r\n<strong>Ik gebruik overspanningsstrips op mijn stopcontacten. Moet ik Type 2 SPD installeren?<\/strong>\r\n\r\nAbsolutely necessary. Surge power strips (Type 3 SPDs) have limited discharge capabilities; they are designed to absorb very small residual surges at the device end. They cannot withstand major surge energy transmitted from the power line.\r\n\r\nWithout a Type 2 SPD dissipating energy at the pre-amplifier stage, a larger surge could directly destroy your surge power strip and connected devices. Type 2 SPDs are the mainstay in protecting the entire circuit branch.\r\n\r\n&nbsp;\r\n\r\n<strong>Eenfasige SPD VS Driefasige SPD type 1<\/strong>\r\n\r\nEenfasige SPD's worden gebruikt in eenfasige voedingssystemen (\u00e9\u00e9n stroomvoerende draad en \u00e9\u00e9n neutrale draad), terwijl driefasige Type 1 SPD's worden gebruikt in driefasige voedingssystemen (drie stroomvoerende draden en \u00e9\u00e9n neutrale draad of drie stroomvoerende draden, \u00e9\u00e9n neutrale draad en \u00e9\u00e9n aarddraad), ontworpen om alle fasedraden te beschermen tegen enorme overspanningen zoals directe blikseminslagen.\r\n<h2 class=\"wp-block-heading\">Conclusie<\/h2>\r\n<div>SPD Type 1 versus Type 2? Kiezen tussen Type 1 en Type 2 SPD's is geen of-of-vraag, maar eerder een vraag over hoe een effectieve bliksembeveiligingshi\u00ebrarchie kan worden opgebouwd.<\/div>\r\n<div>Type 1 SPDs are the \"heavy armor\" against direct lightning strikes and are the mandatory first choice for buildings with external lightning protection systems.<\/div>\r\n<div>Type 2 SPDs are the \"main force\" against everyday surges and are core protection equipment that almost all buildings should have installed.<\/div>\r\n<div>De veiligste en meest betrouwbare strategie is het volgen van een gelaagd beschermingsprincipe: gebruik Type 1 bij hoofdingangen, Type 2 bij verdeelkasten en overspanningsstroken bij uiteindelijke apparatuurlocaties. Via dit gelaagde beveiligingssysteem kunt u de meest uitgebreide bescherming bieden voor uw elektrische apparatuur en eigendommen.<\/div>","protected":false},"featured_media":2246,"parent":0,"menu_order":106,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2241","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"Comparison of Type 1 surge protection device and Type 2 SPD to help you understand their differences, application scenarios, and make the right choice.","txt":"In modern electrical systems, surge protectors (SPDs) are critical devices for protecting against damage from lightning strikes and switch surges. However, many people are confused by the different types, such as Type 1 and Type 2\u00a0surge protection device.\r\n\r\nWhat Is the difference between Type 1 and Type 2 SPD?This article will provide an in-depth comparison of <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\"><strong>Type 1 surge protection device<\/strong><\/a> and Type 2 SPDs to help you understand their differences, application scenarios, and make the right choice.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2. Type 1 Surge Protection Device Vs Type 2 SPD<\/h2>\r\nSurge protectors (SPDs) are the \"safety valves\" of electrical systems. Type 1 and Type 2 are the two most commonly used SPDs. They each have their own functions and work together to build a complete protection system.\r\n<h2 class=\"wp-block-heading\">2.1 Main function of Type 1 and Type 2 SPD<\/h2>\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P Type 1 25kA Lightning Surge Protection Device\" width=\"800\" \/><\/a>\r\n<div><strong>Type 1 SPD (Lightning Current Discharge Device):<\/strong><\/div>\r\n<div>Main Function: Provides protection from direct lightning strikes or partial lightning currents. Usually placed at the main entry point of a building, it gives first-level (basic) protection.<\/div>\r\n<div>Core Task: Handles and redirects large lightning currents to stop damage to equipment and lines downstream.<\/div>\r\n<div><\/div>\r\n<div><strong>Type 2 SPD (Pressure Control Device):<\/strong><\/div>\r\n<div>Main Function: Used for protection against surges from switch operation and residual surges from induced lightning strikes. It is typically installed in distribution boxes (such as floor distribution boxes) and provides second-level (intermediate protection).<\/div>\r\n<div>Core Task: Limits residual voltage to a safe level for terminal equipment, serving as the primary protection for sensitive electronic equipment.<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2 class=\"wp-block-heading\">2.2 Main Test Parameters<\/h2>\r\n<div><strong>Type 1 SPD Single Phase:<\/strong><\/div>\r\n<div>Impulse Current (I&lt;sub&gt;imp&lt;\/sub&gt;): The most critical parameter. It indicates the SPD's ability to withstand a typical lightning current, including peak current (10\/350\u03bcs waveform), charge quantity, and other comprehensive requirements. For example: 25 kA (10\/350\u03bcs).<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/product\/br-20-3p-type-2-20ka-surge-protective-device-for-tn-c\/\" rel=\"attachment wp-att-1711\"><img class=\"alignnone size-full wp-image-1711\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-3P-1.jpg\" alt=\"BR-20 3P Type 2 20kA Surge Protective Device For TN-C\" width=\"800\" \/><\/a><\/div>\r\n<div><strong>Type 2 SPD:<\/strong><\/div>\r\n<div>Nominal Discharge Current (I&lt;sub&gt;n&lt;\/sub&gt;): The core parameter. It indicates the standard test current (8\/20\u03bcs waveform) that the SPD can withstand multiple times. For example: 20 kA (8\/20\u03bcs).<\/div>\r\n<div>Maximum Discharge Current (I&lt;sub&gt;max&lt;\/sub&gt;): Indicates the maximum discharge current (8\/20\u03bcs waveform) that the SPD can withstand in a single operation.<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2 class=\"wp-block-heading\">2.3 Test Waveforms<\/h2>\r\n10\/350\u03bcs waveform (for Type 1 testing): This waveform simulates some of the current characteristics of a direct lightning strike. Its current rise is slow, but its duration is long, carrying approximately 20 times the energy of the 8\/20\u03bcs waveform, making it extremely destructive.\r\n\r\n8\/20\u03bcs waveform (for Type 2 testing): This waveform simulates induced lightning and switching surges. The current rises quickly, its duration is short, and its energy is relatively small.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.4 Installation Location<\/h2>\r\nType 1 lightning surge protection device: Installed in the building's main distribution panel (main incoming line box), located after the electricity meter and before or after the main circuit breaker (depending on product design).\r\n\r\nType 2 SPD: Installed in distribution panels, such as floor distribution boxes or distribution boxes in critical equipment rooms (e.g., data centers, elevator control rooms).\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.5 Reltation of External Surge Protection System<\/h2>\r\nType 1 SPD: Must be installed at the power inlet of buildings equipped with external lightning protection systems (lightning rods, down conductors). This is a mandatory requirement of international standards (such as IEC 62305) because it effectively handles direct lightning current coupled from the down conductor to the power line.\r\n\r\nType 2 SPD: Not directly mandatory with external lightning protection systems. Type 2 SPDs are required to handle induced surges regardless of whether the building has an external lightning protection system.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">2.6 Coordination<\/h2>\r\nType 1 and Type 2 SPDs need to work together. A certain line distance must be maintained between them (generally recommended to be at least 10 meters), or decoupling devices (such as dedicated reactors) should be used to ensure that, in the event of a surge, the Type 1 SPD trips first to dissipate most of the energy, and then the Type 2 SPD trips to limit the residual voltage to a lower level. If the distance is insufficient, a large surge may bypass the Type 1 and damage the Type 2.\r\n\r\n&nbsp;\r\n<h2 class=\"wp-block-heading\">Do I Need Type 1 Or Type 2 SPD?<\/h2>\r\nThis is a decision-making process to help you make a choice:\r\n<h3><strong>Does The Building Have An External Surge Protection System?<\/strong><\/h3>\r\nYes: You must install a Type 1 SPD in the main distribution box.\r\n\r\nNo\/Unsure: You can skip Type 1, but installing Type 2 is strongly recommended.\r\n<h3><strong>Surge Risk Assessment At Incoming Power Line<\/strong><\/h3>\r\nEven without an external lightning protection system, if your building is located in an open area, on a hilltop, or has long overhead power lines, the risk of lightning strikes is high. Installing a Type 1 SPD can provide a higher level of protection.\r\n<h3><strong>Decide Selection<\/strong><\/h3>\r\nScenario A (Standard residential building, no external lightning protection): Installing a Type 2 SPD in the main distribution box provides sufficient protection.\r\n\r\nScenario B (Villa\/commercial building with lightning rod): A Type 1 SPD must be installed in the main distribution box, and Type 2 SPDs must be installed in floor distribution boxes or distribution boxes for critical equipment.\r\n\r\nScenario C (Risk compromise): If space or budget is limited, a Type 1+2 combined SPD can be installed in the main distribution box (see FAQ).\r\n<h2 class=\"wp-block-heading\">Concept Of Graded (Coordinated) Protection<\/h2>\r\n<h3>Why Is Graded Protection Necessary?<\/h3>\r\nNo single SPD can perfectly handle all types of surges. The concept of tiered protection is:\r\n\r\nType 1 (Level 1): Intercepts and discharges the vast majority of the enormous energy (e.g., 90%) at the inlet.\r\n\r\nType 2 (Level 2): \u200b\u200bFurther limits the residual surge voltage after the first level, bringing it within the equipment's safe range.\r\n\r\nType 3 (Fine Protection): Uses surge strips at the equipment end to provide fine protection for the last mile.\r\n\r\nThis is like a line of defense: the first line weakens the main force, the second line clears the residue, and ensures the safety of the main base (your equipment).\r\n<h3>Typical Graded Protection Scheme<\/h3>\r\nA complete solution is as follows:\r\n\r\nLevel I: Main Distribution Box \u2192 Type 1 SPD\r\n\r\nLevel II: Floor Distribution Box \u2192 Type 2 SPD\r\n\r\nLevel III: Equipment Front-End (e.g., sockets) \u2192 Type 3 SPD (surge power strip)\r\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\r\n<strong>Can I Install Both Type 1 And Type 2 Single Phase SPD?<\/strong>\r\n\r\nAbsolutely, and it's best practice. Type 1 and Type 2 single phase SPDs work together to provide tiered protection from the inlet to the device.\r\n\r\n<strong>Difference Between Type 1+2 Combined Spd And Installing Them Separately<\/strong>\r\n<div>Type 1+2 Combined SPD: A single device integrates both Type 1 and Type 2 modules. Its advantages include space saving and easy installation, making it particularly suitable for scenarios with limited space in the main distribution box. It has passed coordination testing to ensure proper module compatibility.<\/div>\r\n<div><\/div>\r\n<div>Separate Installation: Offers maximum flexibility and maintainability. If a Type 1 module is damaged, only the Type 1 module can be replaced without affecting the Type 2 module. However, sufficient distance must be ensured between them, or a decoupling device must be used.<\/div>\r\n<div><\/div>\r\n<strong>I Use Surge Strips On My Outlets. Do I Need To Install Type 2 SPD?<\/strong>\r\n\r\nAbsolutely necessary. Surge power strips (Type 3 SPDs) have limited discharge capabilities; they are designed to absorb very small residual surges at the device end. They cannot withstand major surge energy transmitted from the power line.\r\n\r\nWithout a Type 2 SPD dissipating energy at the pre-amplifier stage, a larger surge could directly destroy your surge power strip and connected devices. Type 2 SPDs are the mainstay in protecting the entire circuit branch.\r\n\r\n&nbsp;\r\n\r\n<strong>Single Phase SPD VS Three phase Type 1 SPD<\/strong>\r\n\r\nSingle-phase SPDs are used in single-phase power supply systems (one live wire and one neutral wire), while three-phase Type 1 SPDs are used in three-phase power supply systems (three live wires and one neutral wire or three live wires, one neutral wire, and one ground wire), designed to protect all phase wires from massive surge impacts such as direct lightning strikes.\r\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\r\n<div>SPD Type 1 Vs Type 2?Choosing between Type 1 and Type 2 SPDs is not an either-or question, but rather a question of how to build an effective lightning protection hierarchy.<\/div>\r\n<div>Type 1 SPDs are the \"heavy armor\" against direct lightning strikes and are the mandatory first choice for buildings with external lightning protection systems.<\/div>\r\n<div>Type 2 SPDs are the \"main force\" against everyday surges and are core protection equipment that almost all buildings should have installed.<\/div>\r\n<div>The safest and most reliable strategy is to follow a tiered protection principle: deploy Type 1 at main entrances, Type 2 at distribution boxes, and surge strips at final equipment locations. Through this layered protection system, you can provide the most comprehensive protection for your electrical equipment and property.<\/div>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog\/2241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media\/2246"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media?parent=2241"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog_category?post=2241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}