{"id":2231,"date":"2025-10-31T09:43:00","date_gmt":"2025-10-31T01:43:00","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2231"},"modified":"2025-11-03T16:21:24","modified_gmt":"2025-11-03T08:21:24","slug":"types-of-industrial-surge-protection-devices-and-graded-protection-strategies","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/nl\/blog\/types-of-industrial-surge-protection-devices-and-graded-protection-strategies\/","title":{"rendered":"Soorten industri\u00eble overspanningsbeveiligingsapparaten en graduele beveiligingsstrategie\u00ebn"},"content":{"rendered":"<div>Dit artikel introduceert systematisch de typen, classificatiemethoden en hoe u een effectief gegradueerd beveiligingssysteem kunt bouwen <a href=\"https:\/\/www.britecelectric.com\/nl\/products\/\"><strong>industri\u00eble overspanningsbeveiligers (SPD)<\/strong><\/a>.<\/div>\r\n&nbsp;\r\n<h2>Classificatie volgens technisch principe en afvoercapaciteit<\/h2>\r\n<div>Dit is de kernclassificatiemethode voor SPD, die rechtstreeks hun toepassingsscenario's en beschermingsniveaus bepaalt, en is meestal gebaseerd op internationale normen zoals IEC 61643.<\/div>\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone size-medium wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P Type 1 25kA bliksembeveiligingsapparaat\" width=\"300\" \/><\/a>\r\n<h3>Type 1 (Type 1\/T1): Energieontlading<\/h3>\r\n<div><strong>Technisch principe: <\/strong><a href=\"https:\/\/www.britecelectric.com\/nl\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\">Type 1-overspanningsbeveiligingsapparaten<\/a> gebruikt doorgaans een vonkbrug als kerncomponent. Het belangrijkste kenmerk is het hoge ontladingsvermogen van stroomstoten.<\/div>\r\n<div><strong>Lossingsvermogen: <\/strong>Bestand tegen directe blikseminslagen of gedeeltelijke bliksemstroom (simulatie van een golfvorm van 10\/350 \u00b5s); teststromen kunnen doorgaans tientallen kiloamp\u00e8re bereiken.<\/div>\r\n<div><strong>Toepassingsscenario's: <\/strong>Primarily installed at the entrance of the building's main distribution cabinet (MDB) as a primary protection device to release lightning current from external lines (e.g., power lines).<\/div>\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-20-4p-type-2-20ka-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1709\"><img class=\"alignnone size-medium wp-image-1709\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-4P-1.jpg\" alt=\"BR-20 4P Type 2 20kA overspanningsbeveiliging voor TNS\" width=\"300\" \/><\/a>\r\n<h3>Type 2 (Type 2\/T2): spanningsbegrenzer<\/h3>\r\n<div>Technisch principe: De kerncomponent is een varistor (MOV). Onder normale spanning vertoont de MOV een hoge weerstand; wanneer er een overspanning optreedt, daalt de weerstand ervan scherp, waardoor de stroom wordt omzeild en de spanning op een veilig niveau wordt gehouden.<\/div>\r\n<div>Lossingscapaciteit: <a href=\"https:\/\/www.britecelectric.com\/nl\/product-category\/ac-power-surge-protection\/type-2-surge-protective-device\/\">Type 2 overspanningsbeveiligingsapparaten<\/a> Wordt gebruikt voor het ontladen van ge\u00efnduceerde blikseminslagen en operationele overspanningen (simulatie van de golfvorm van 8\/20 \u00b5s), met een ontladingscapaciteit die doorgaans varieert van enkele duizenden tot tienduizenden amp\u00e8re.<\/div>\r\n<div>Toepassingsscenario's: Ge\u00efnstalleerd stroomafwaarts van de hoofdverdeelkast in de verdeelkast (verdeelpaneel, SDB) of v\u00f3\u00f3r de schakelkast van belangrijke apparatuur, dienend als secundaire bescherming om bescherming te bieden voor de meeste elektrische apparatuur.<\/div>\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-230-type-3-surge-protector\/\" rel=\"attachment wp-att-1198\"><img class=\"alignnone size-medium wp-image-1198\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-230.jpg\" alt=\"BR-230 Type 3 overspanningsbeveiliging\" width=\"300\" \/><\/a>\r\n<h3>Type 3 (Type 3\/T3): Geavanceerde bescherming<\/h3>\r\n<div>Technisch principe: Maakt doorgaans gebruik van fijnere MOV's, gasontladingsbuizen of TVS-diodes, wat resulteert in een extreem snelle respons en een lagere restspanning (beschermingsniveau).<\/div>\r\n<div>Ontladingscapaciteit: De ontladingscapaciteit is relatief klein en wordt voornamelijk gebruikt om de resterende overspanning verder te onderdrukken.<\/div>\r\n<div>Toepassingsscenario's: <a href=\"https:\/\/www.britecelectric.com\/nl\/product_category\/type-3-surge-protector\/\">Type 3-overspanningsbeveiligingsapparaten<\/a> installed very close to the protected equipment, such as in the equipment's socket or socket board, for fine protection. It usually needs to be used in conjunction with a Type 2 SPD and cannot be installed alone.<\/div>\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/nl\/product\/br-12-5m-4p-12-5ka-type-12-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1637\"><img class=\"alignnone size-medium wp-image-1637\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-1.jpg\" alt=\"BR-12.5M 4P 12,5kA Type 1+2 overspanningsbeveiligingsapparaat voor TNS\" width=\"300\" \/><\/a>\r\n<h3>Gecombineerde versnelling (type 1+2): ge\u00efntegreerde oplossing<\/h3>\r\n<div>Technisch principe: Dit apparaat integreert een Type 1-vonkbrug en een Type 2-varistor en biedt de voordelen van een hoog ontladingsvermogen en een laag beschermingsniveau.<\/div>\r\n<div>Toepassingsscenario's: <a href=\"https:\/\/www.britecelectric.com\/nl\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\">Gecombineerde SPD (Type 1+2) overspanningsbeveiligingsapparaten<\/a> geschikt voor toepassingen met beperkte ruimte of die een vereenvoudigd ontwerp vereisen. Het kan direct in de hoofdverdeelkast bij de ingang van het gebouw worden ge\u00efnstalleerd, waardoor een gecombineerde bescherming op het eerste en tweede niveau wordt geboden.<\/div>\r\n&nbsp;\r\n<h2>Uitgebreide classificatie van industri\u00eble overspanningsbeveiligingsapparaten<\/h2>\r\n<div>Naast de typen kerntechnologie kunnen industri\u00eble SPD's ook op basis van andere dimensies worden geclassificeerd.<\/div>\r\n<h3>Classificatie per type stroombron<\/h3>\r\n<div>AC-voeding SPD: Wordt gebruikt om AC-voedingssystemen te beschermen, zoals industri\u00eble elektriciteitsnetten van 380V\/220V.<\/div>\r\n<div>DC-voeding SPD: Wordt gebruikt om DC-voedingssystemen te beschermen, zoals fotovolta\u00efsche energieopwekkingssystemen, DC-motoraandrijvingen en voedingen voor communicatiebasisstations.<\/div>\r\n&nbsp;\r\n<h4>Wisselstroom-SPD versus gelijkstroom-SPD<\/h4>\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Functie<\/th>\r\n<th>Wisselstroom-SPD<\/th>\r\n<th>Gelijkstroom-SPD<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><strong>Primaire toepassing<\/strong><\/td>\r\n<td>Elektrische hoofdpanelen, subpanelen, vertakte circuits in woningen, kantoren en industri\u00eble faciliteiten.<\/td>\r\n<td>Zonne-PV-arrays, batterijopslagsystemen, EV-laadstations, telecommunicatie, auto-, scheepvaart- en openbaar vervoer.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Systeemspanning<\/strong><\/td>\r\n<td>Volgt standaard AC-spanningen (bijv. 120V, 230V, 400V, 480V).<\/td>\r\n<td>Zeer variabel (bijv. 12V, 24V, 48V voor batterijen; 600V tot 1500V voor zonne-energiestrings).<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Huidig \u200b\u200bgedrag<\/strong><\/td>\r\n<td><strong>Wisselstroom.<\/strong>\u00a0De spanning overschrijdt 100 tot 120 keer per seconde nul. Dit helpt\u00a0<strong>een elektrische boog doven<\/strong>.<\/td>\r\n<td><strong>Gelijkstroom.<\/strong>\u00a0De spanning is constant en gaat niet door nul. Dit maakt\u00a0<strong>boogvorming is veel duurzamer en gevaarlijker<\/strong>.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Belangrijke ontwerpuitdaging<\/strong><\/td>\r\n<td>Beheer van voorbijgaande overspanningen. De nuldoorgang van AC helpt op natuurlijke wijze de volgstroom te onderbreken.<\/td>\r\n<td><strong>Boogonderdrukking.<\/strong>\u00a0The primary challenge is to safely quench the \"follow current\" from the DC source after a surge event without the SPD catching fire.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Interne technologie en componenten<\/strong><\/td>\r\n<td>Gebruikt voornamelijk\u00a0<strong>Metaaloxidevaristoren (MOV's)<\/strong>\u00a0en soms gasontladingsbuizen (GDT's). Ontwerpen zijn relatief eenvoudig.<\/td>\r\n<td>Gebruikt robuuster\u00a0<strong>MOV's<\/strong>\u00a0met speciale boogdovende kamers\/vulstoffen. Zwaardere afhankelijkheid van\u00a0<strong>GDT's<\/strong>\u00a0speciaal ontworpen voor DC, die de continue gelijkspanning veilig kan verwerken zonder te lekken.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Spanningswaarde (Uc)<\/strong><\/td>\r\n<td>Gespecificeerd voor continu gebruik bij standaard AC RMS-spanningen (bijv. 275V, 320V, 440V).<\/td>\r\n<td>Gespecificeerd voor continu gebruik bij de specifieke DC-systeemspanning (bijv. 1000 V DC, 1500 V DC).<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Ontkoppeling en veiligheid<\/strong><\/td>\r\n<td>Bevat vaak thermische scheiders om een \u200b\u200bMOV die door vele spanningspieken is beschadigd veilig uit te schakelen.<\/td>\r\n<td><strong>Kritisch en robuuster.<\/strong>\u00a0Vereist geavanceerde faalmechanismen om de SPD op een fail-safe manier fysiek los te koppelen van de DC-bron, aangezien een aanhoudende DC-boog een groot brandgevaar vormt.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Certificeringsnormen<\/strong><\/td>\r\n<td>UL 1449 (Noord-Amerika), IEC 61643-11 (internationaal).<\/td>\r\n<td>UL 1449 (voor specifieke DC-toepassingen), IEC 61643-11, UL 497B en specifieke normen voor PV-systemen zoals IEC 62548.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;\r\n<h3>Classificatie op signaaltype<\/h3>\r\n<div>Industri\u00eble omgevingen bevatten niet alleen stroomleidingen, maar ook talrijke signaal- en besturingsleidingen. Signaal-SPD's zijn speciaal ontworpen om deze laagspanningslijnen te beschermen, zoals:<\/div>\r\n<div>\u25cf Netwerk\/Ethernet-SPD<\/div>\r\n<div>\u25cf RS-232\/485\/422 seri\u00eble poort SPD<\/div>\r\n<div>\u25cf Analoge\/digitale I\/O SPD<\/div>\r\n<div>\u25cf Coaxkabel SPD (gebruikt voor videobewaking, antennes, enz.)<\/div>\r\n&nbsp;\r\n<h3>Classificatie op basis van montagestructuur<\/h3>\r\n<h4>Plug-in overspanningsbeveiligingsapparaten<\/h4>\r\n<div>Het ziet eruit als een adapter en kan rechtstreeks in een stopcontact worden gestoken. Het wordt voornamelijk gebruikt om \u00e9\u00e9n apparaat te beschermen en behoort tot Type 3.<\/div>\r\n&nbsp;\r\n<h4>Modulaire overspanningsbeveiligingsapparaten<\/h4>\r\n<div>Het standaard modulaire ontwerp maakt montage op een DIN-rail in een verdeelkast mogelijk, net als een stroomonderbreker. Dit is de meest voorkomende vorm in industri\u00eble toepassingen en vergemakkelijkt de installatie, vervanging en conditiebewaking (via signaleringscontacten op afstand). Type 1 en Type 2 zijn meestal van dit type.<\/div>\r\n&nbsp;\r\n<h4>Overspanningsbeveiligingsapparaten van het doostype<\/h4>\r\n<div>SPD-modules, zekeringen of stroomonderbrekers zijn ge\u00efntegreerd in een enkele beschermende behuizing, die vaak wordt gebruikt in dozen voor buiten- of veldapparatuur.<\/div>\r\n&nbsp;\r\n<h2>Hoe bouw je een gelaagd (stapsgewijs) beveiligingssysteem?<\/h2>\r\n<div>E\u00e9n enkele SPD kan geen perfecte bescherming bieden, dus is een gelaagde (of getrapte) beschermingsstrategie vereist.<\/div>\r\n<h4>Principe van gelaagde bescherming<\/h4>\r\n<div>The core concept of graded protection is \"step-by-step discharge and layer-by-layer clamping.\"<\/div>\r\n<div>Niveau 1 (Type 1\/Type 1+2): Op de hoofdinkomende lijn absorbeert en ontlaadt het de overgrote meerderheid van de enorme piekenergie, waardoor overspanningen van enkele kilovolt tot een lager niveau worden beperkt (bijvoorbeeld 1500-2500 V).<\/div>\r\n<div>Niveau 2 (Type 2): Op het verdeelpaneel ontlaadt het de restspanningen die niveau 1 zijn binnengedrongen verder en klemt de spanning vast op een veiliger niveau (bijvoorbeeld 1000-1500 V).<\/div>\r\n<div>Niveau 3 (Type 3): Aan de voorkant van de apparatuur zorgt het voor de definitieve onderdrukking van kleine restspanningen, waardoor de laagst mogelijke restspanning wordt geboden (doorgaans minder dan 1000 V), waardoor de absolute veiligheid van poorten voor precisieapparatuur wordt gegarandeerd.<\/div>\r\n<div>Er moet een bepaalde lijnafstand (doorgaans aanbevolen meer dan 10 meter) worden aangehouden tussen elk SPD-niveau om de lijnimpedantie te gebruiken voor energieco\u00f6rdinatie. Als de afstand onvoldoende is, zijn ontkoppelingscomponenten (zoals speciale ontkoppelingsinductoren of geschikte zekeringen\/stroomonderbrekers) vereist om ervoor te zorgen dat elk SPD-niveau in een geco\u00f6rdineerde volgorde werkt.<\/div>\r\n&nbsp;\r\n<h4>Voorbeeld van Spd-configuratie in typische industri\u00eble scenario's<\/h4>\r\n<div>Scenario: Geautomatiseerd productielijncontrolecentrum<\/div>\r\n<div>Hoofdverdeelruimte (MDB): Installeer Type 1+2 SPD's om de stroomtoevoer naar het hele gebouw te beschermen.<\/div>\r\n<div>Productielijnbesturingskast (SDB): Installeer Type 2 SPD's om de stroomvoorziening naar kernbesturingseenheden zoals PLC's en frequentieomvormers te beschermen.<\/div>\r\n<div>PLC I\/O-module Voorzijde: Installeer signaal-SPD's op besturingssignaallijnen (bijv. 24V DC).<\/div>\r\n<div>Engineerwerkstation: Gebruik Type 3 SPD-socketkaarten op de sockets om de computer en de programmeur te beschermen.<\/div>\r\n<div>Workshop Netwerkswitch: Installeer Ethernet SPD's op de netwerkpoorten.<\/div>\r\n&nbsp;\r\n<h2>Veelgestelde vragen<\/h2>\r\n<div><strong>Hoe selecteert u het juiste SPD-type op basis van de omstandigheden ter plaatse?<\/strong><\/div>\r\n<div>Stap 1: Bepaal de installatielocatie. Selecteer T1 of T1+2 voor de hoofdinkomende lijnkast; T2 voor de verdeelkast; en T3 voor de voorkant van de apparatuur.<\/div>\r\n<div>Stap 2: Controleer de belangrijkste parameters. De maximale continue bedrijfsspanning (Uc) moet groter zijn dan de hoogste spanning die in het lokale elektriciteitsnet mag voorkomen; de nominale ontlaadstroom (In) en maximale ontlaadstroom (Imax) moeten voldoen aan de eisen van het bliksembeveiligingsniveau (LPL) van het installatiepunt; het spanningsbeveiligingsniveau (Up) moet lager zijn dan de weerstandsspanningswaarde van de beschermde apparatuur.<\/div>\r\n<div>Stap 3: Houd rekening met andere factoren, zoals het voedingssysteem (AC\/DC), installatiemethode (modulair\/box-type), statusindicatie en vereisten voor de functie voor signalering op afstand.<\/div>\r\n&nbsp;\r\n<div><strong>Dagelijkse inspectie en onderhoud van industri\u00eble SPD<\/strong><\/div>\r\n<div>Regelmatige visuele inspectie: Controleer de SPD op fysieke schade, zoals scheuren of brandplekken.<\/div>\r\n<div>Let op de statusindicator: de meeste SPD's hebben een kleurgecodeerde vensterindicator (groen\/rood). Groen duidt op een normale werking en rood duidt op een storing die onmiddellijke vervanging vereist.<\/div>\r\n<div>Houd een onderhoudslogboek bij: noteer de installatiedatum, de datum van de eerste inspectie en de details van de daaropvolgende inspectie. Zelfs in normale toestand hebben SPD's een beperkte levensduur; het wordt aanbevolen om ze periodiek te inspecteren of te vervangen (bijvoorbeeld elke 3-5 jaar) of na een grote overspanning.<\/div>\r\n<div>Professioneel testen: gebruik gespecialiseerde instrumenten om de lekstroom van de varistor te meten en de prestatievermindering te beoordelen.<\/div>\r\n&nbsp;\r\n<div><strong>Kunnen overspanningsbeveiligingsapparaten voorkomen dat stroomonderbrekers struikelen?<\/strong><\/div>\r\n<div>De primaire functie van een SPD is om te voorkomen dat apparatuur beschadigd raakt door overspanning, en niet om te voorkomen dat stroomonderbrekers uitschakelen.<\/div>\r\n&nbsp;\r\n<h2>Conclusie<\/h2>\r\n<div>Door de technische principes en toepassingsscenario's van verschillende soorten industri\u00eble overspanningsbeveiligingsapparaten (SPD) (t1, t2, t3) te begrijpen en deze te combineren met uitgebreide bescherming van stroom- en signaallijnen, kunnen we een effectief hi\u00ebrarchisch (stapsgewijs) beveiligingssysteem bouwen.<\/div>","protected":false},"featured_media":1601,"parent":0,"menu_order":107,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2231","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"This article provides a detailed analysis of the Type 1\/2\/3 industrial surge protection devices (SPD) and their technical principles, explains how to construct an effective hierarchical (step-by-step) protection strategy to ensure the safety of industrial equipment, and answers common selection and maintenance questions.","txt":"<div>This article will systematically introduce the types, classification methods, and how to build an effective graded protection system for <a href=\"https:\/\/www.britecelectric.com\/products\/\"><strong>industrial surge protectors (SPD)<\/strong><\/a>.<\/div>\r\n&nbsp;\r\n<h2>Classification By Technical Principle And Discharge Capacity<\/h2>\r\n<div>This is the core classification method for SPD, which directly determines their application scenarios and protection levels, and is usually based on international standards such as IEC 61643.<\/div>\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone size-medium wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P Type 1 25kA Lightning Surge Protection Device\" width=\"300\" \/><\/a>\r\n<h3>Type 1 (Type 1\/T1): Energy Discharge<\/h3>\r\n<div><strong>Technical Principle: <\/strong><a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-lightning-surge-protection-device\/\">Type 1 surge protection devices<\/a> typically uses a spark gap as its core component. Its main characteristic is its high surge current discharge capability.<\/div>\r\n<div><strong>Discharge Capability: <\/strong>Capable of withstanding and releasing direct lightning strikes or partial lightning current (simulating a 10\/350\u00b5s waveform); test currents can typically reach tens of kiloamperes.<\/div>\r\n<div><strong>Application Scenarios: <\/strong>Primarily installed at the entrance of the building's main distribution cabinet (MDB) as a primary protection device to release lightning current from external lines (e.g., power lines).<\/div>\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-20-4p-type-2-20ka-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1709\"><img class=\"alignnone size-medium wp-image-1709\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-4P-1.jpg\" alt=\"BR-20 4P Type 2 20kA Surge Protective Device For TNS\" width=\"300\" \/><\/a>\r\n<h3>Type 2 (Type 2\/T2): Voltage Limiter<\/h3>\r\n<div>Technical Principle: The core component is a varistor (MOV). Under normal voltage, the MOV exhibits high resistance; when a surge overvoltage occurs, its resistance drops sharply, bypassing the current and clamping the voltage to a safe level.<\/div>\r\n<div>Discharge Capacity: <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-2-surge-protective-device\/\">Type 2 surge protection devices<\/a> Used to discharge induced lightning strikes and operational overvoltages (simulating 8\/20\u00b5s waveform), with a discharge capacity typically ranging from several thousand to tens of thousands of amperes.<\/div>\r\n<div>Application Scenarios: Installed downstream of the main distribution cabinet in the distribution cabinet (distribution panel, SDB) or before the control cabinet of important equipment, serving as secondary protection to provide protection for most electrical equipment.<\/div>\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-230-type-3-surge-protector\/\" rel=\"attachment wp-att-1198\"><img class=\"alignnone size-medium wp-image-1198\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-230.jpg\" alt=\"BR-230 Type 3 Surge Protector\" width=\"300\" \/><\/a>\r\n<h3>Type 3 (Type 3\/T3): Advanced Protection<\/h3>\r\n<div>Technical Principle: Typically employs finer MOVs, gas discharge tubes, or TVS diodes, resulting in extremely fast response and lower residual voltage (protection level).<\/div>\r\n<div>Discharge Capacity: The discharge capacity is relatively small, primarily used to further suppress residual surge voltage.<\/div>\r\n<div>Application Scenarios: <a href=\"https:\/\/www.britecelectric.com\/product_category\/type-3-surge-protector\/\">Type 3 surge protection devices<\/a> installed very close to the protected equipment, such as in the equipment's socket or socket board, for fine protection. It usually needs to be used in conjunction with a Type 2 SPD and cannot be installed alone.<\/div>\r\n&nbsp;\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-12-5m-4p-12-5ka-type-12-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1637\"><img class=\"alignnone size-medium wp-image-1637\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-1.jpg\" alt=\"BR-12.5M 4P 12.5kA Type 1+2 Surge Protective Device For TNS\" width=\"300\" \/><\/a>\r\n<h3>Combined Spd (Type 1+2): Integrated Solution<\/h3>\r\n<div>Technical Principle: This device integrates a Type 1 spark gap and a Type 2 varistor, offering the advantages of high discharge capability and low protection level.<\/div>\r\n<div>Application Scenarios: <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-1-2-lightning-surge-arrester\/\">Combined SPD (Type 1+2) surge protection devices<\/a> suitable for applications with limited space or requiring simplified design. It can be directly installed in the main distribution cabinet at the building entrance, providing combined first- and second-level protection.<\/div>\r\n&nbsp;\r\n<h2>Extended Classification Of Industrial Surge Protection Devices<\/h2>\r\n<div>In addition to core technology types, industrial SPDs can also be classified according to other dimensions.<\/div>\r\n<h3>Classification By Power Source Type<\/h3>\r\n<div>AC power supply SPD: Used to protect AC power supply systems, such as 380V\/220V industrial power grids.<\/div>\r\n<div>DC power supply SPD: Used to protect DC power supply systems, such as photovoltaic power generation systems, DC motor drives, and communication base station power supplies.<\/div>\r\n&nbsp;\r\n<h4>AC Power SPD VS Dc Power SPD<\/h4>\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Feature<\/th>\r\n<th>AC Power SPD<\/th>\r\n<th>DC Power SPD<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><strong>Primary Application<\/strong><\/td>\r\n<td>Main electrical panels, sub-panels, branch circuits in homes, offices, and industrial facilities.<\/td>\r\n<td>Solar PV arrays, battery storage systems, EV charging stations, telecommunications, automotive, marine, and public transport.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>System Voltage<\/strong><\/td>\r\n<td>Follows standard AC voltages (e.g., 120V, 230V, 400V, 480V).<\/td>\r\n<td>Highly variable (e.g., 12V, 24V, 48V for batteries; 600V to 1500V for solar strings).<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Current Behavior<\/strong><\/td>\r\n<td><strong>Alternating Current.<\/strong>\u00a0The voltage crosses zero 100 or 120 times per second. This helps\u00a0<strong>extinguish an electrical arc<\/strong>.<\/td>\r\n<td><strong>Direct Current.<\/strong>\u00a0The voltage is constant and does not cross zero. This makes\u00a0<strong>arcing much more sustained and dangerous<\/strong>.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Key Design Challenge<\/strong><\/td>\r\n<td>Managing transient overvoltages. The zero-crossing of AC naturally helps interrupt follow current.<\/td>\r\n<td><strong>Arc Suppression.<\/strong>\u00a0The primary challenge is to safely quench the \"follow current\" from the DC source after a surge event without the SPD catching fire.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Internal Technology &amp; Components<\/strong><\/td>\r\n<td>Primarily uses\u00a0<strong>Metal Oxide Varistors (MOVs)<\/strong>\u00a0and sometimes Gas Discharge Tubes (GDTs). Designs are relatively straightforward.<\/td>\r\n<td>Uses more robust\u00a0<strong>MOVs<\/strong>\u00a0with special arc-quenching chambers\/fillers. Heavier reliance on\u00a0<strong>GDTs<\/strong>\u00a0specifically designed for DC, which can safely handle the continuous DC voltage without leaking.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Voltage Rating (Uc)<\/strong><\/td>\r\n<td>Rated for continuous operation at standard AC RMS voltages (e.g., 275V, 320V, 440V).<\/td>\r\n<td>Rated for continuous operation at the specific DC system voltage (e.g., 1000V DC, 1500V DC).<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Disconnection &amp; Safety<\/strong><\/td>\r\n<td>Often includes thermal disconnectors to safely fail an MOV that has been degraded by many surges.<\/td>\r\n<td><strong>Critical and more robust.<\/strong>\u00a0Requires advanced failure mechanisms to physically disconnect the SPD from the DC source in a fail-safe manner, as a sustained DC arc is a major fire hazard.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Certification Standards<\/strong><\/td>\r\n<td>UL 1449 (North America), IEC 61643-11 (International).<\/td>\r\n<td>UL 1449 (for specific DC applications), IEC 61643-11, UL 497B, and specific standards for PV systems like IEC 62548.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;\r\n<h3>Classification By Signal Type<\/h3>\r\n<div>Industrial environments contain not only power lines but also numerous signal and control lines. Signal SPDs are specifically designed to protect these low-voltage lines, such as:<\/div>\r\n<div>\u25cf Network\/Ethernet SPD<\/div>\r\n<div>\u25cf RS-232\/485\/422 Serial Port SPD<\/div>\r\n<div>\u25cf Analog\/Digital I\/O SPD<\/div>\r\n<div>\u25cf Coaxial Cable SPD (used for video surveillance, antennas, etc.)<\/div>\r\n&nbsp;\r\n<h3>Classification By Mounting Structure<\/h3>\r\n<h4>Plug-In Surge Protective Devices<\/h4>\r\n<div>It looks like an adapter and plugs directly into a wall socket. It is mainly used to protect a single device and belongs to Type 3.<\/div>\r\n&nbsp;\r\n<h4>Modular Surge Protective Devices<\/h4>\r\n<div>The standard modular design allows it to be mounted on a DIN rail in a distribution cabinet, just like a circuit breaker. This is the most common form in industrial applications, facilitating installation, replacement, and condition monitoring (via remote signaling contacts). Type 1 and Type 2 are mostly of this type.<\/div>\r\n&nbsp;\r\n<h4>Box-Type Surge Protective Devices<\/h4>\r\n<div>SPD modules, fuses, or circuit breakers are integrated into a single protective enclosure, which is commonly used in outdoor or field equipment boxes.<\/div>\r\n&nbsp;\r\n<h2>How To Build A Tiered (Stepped) Protection System?<\/h2>\r\n<div>A single SPD cannot provide perfect protection, so a tiered (or stepped) protection strategy is required.<\/div>\r\n<h4>Principle Of Tiered Protection<\/h4>\r\n<div>The core concept of graded protection is \"step-by-step discharge and layer-by-layer clamping.\"<\/div>\r\n<div>Level 1 (Type 1\/Type 1+2): At the main incoming line, it absorbs and discharges the vast majority of the massive surge energy, limiting overvoltages of several kilovolts to a lower level (e.g., 1500-2500V).<\/div>\r\n<div>Level 2 (Type 2): At the distribution panel, it further discharges residual surges that have penetrated Level 1 and clamps the voltage to a safer level (e.g., 1000-1500V).<\/div>\r\n<div>Level 3 (Type 3): At the front end of the equipment, it provides final suppression of minor residual surges, offering the lowest possible residual voltage (typically below 1000V), ensuring the absolute safety of precision equipment ports.<\/div>\r\n<div>A certain line distance (generally recommended to be more than 10 meters) needs to be maintained between each level of SPD to utilize line impedance for energy coordination. If the distance is insufficient, decoupling components (such as dedicated decoupling inductors or appropriate fuses\/circuit breakers) are required to ensure that each level of SPD operates in a coordinated sequence.<\/div>\r\n&nbsp;\r\n<h4>Example Of Spd Configuration In Typical Industrial Scenarios<\/h4>\r\n<div>Scenario: Automated Production Line Control Center<\/div>\r\n<div>Main Distribution Room (MDB): Install Type 1+2 SPDs to protect the power input to the entire building.<\/div>\r\n<div>Production Line Control Cabinet (SDB): Install Type 2 SPDs to protect the power supply to core control units such as PLCs and frequency converters.<\/div>\r\n<div>PLC I\/O Module Front: Install signal SPDs on control signal lines (e.g., 24V DC).<\/div>\r\n<div>Engineer Workstation: Use Type 3 SPD socket boards on the sockets to protect the computer and programmer.<\/div>\r\n<div>Workshop Network Switch: Install Ethernet SPDs on the network ports.<\/div>\r\n&nbsp;\r\n<h2>FAQ<\/h2>\r\n<div><strong>How To Select The Appropriate SPD Type Based On Site Conditions?<\/strong><\/div>\r\n<div>Step 1: Determine the installation location. Select T1 or T1+2 for the main incoming line cabinet; T2 for the distribution cabinet; and T3 for the equipment front end.<\/div>\r\n<div>Step 2: Check key parameters. The maximum continuous operating voltage (Uc) must be greater than the highest voltage that may occur in the local power grid; the nominal discharge current (In) and maximum discharge current (Imax) must meet the lightning protection level (LPL) requirements of the installation point; the voltage protection level (Up) should be lower than the withstand voltage value of the protected equipment.<\/div>\r\n<div>Step 3: Consider other factors, such as the power supply system (AC\/DC), installation method (modular\/box-type), status indication, and remote signaling function requirements.<\/div>\r\n&nbsp;\r\n<div><strong>Daily Inspection And Maintenance Of Industrial SPD<\/strong><\/div>\r\n<div>Regular visual inspection: Check the SPD for physical damage, such as cracks or burn marks.<\/div>\r\n<div>Observe the status indicator: Most SPDs have a color-coded window (green\/red) indicator. Green indicates normal operation, and red indicates failure, requiring immediate replacement.<\/div>\r\n<div>Keep a maintenance log: Record the installation date, initial inspection date, and subsequent inspection details. Even when in normal condition, SPDs have a limited lifespan; it is recommended to inspect or replace them periodically (e.g., every 3-5 years) or after a major surge event.<\/div>\r\n<div>Professional testing: Use specialized instruments to measure the leakage current of the varistor and assess for performance degradation.<\/div>\r\n&nbsp;\r\n<div><strong>Can Surge Protection Devices Prevent Circuit Breakers From Tripping?<\/strong><\/div>\r\n<div>The primary function of an SPD is to prevent equipment from being damaged by overvoltage, not to prevent circuit breakers from tripping.<\/div>\r\n&nbsp;\r\n<h2>Conclusion<\/h2>\r\n<div>Understanding the technical principles and application scenarios of different types of industrial surge protection devices (SPD) (t1, t2, t3), and combining them with comprehensive protection of power and signal lines, we can build an effective hierarchical (step-by-step) protection system.<\/div>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog\/2231","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media\/1601"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/media?parent=2231"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/nl\/wp-json\/wp\/v2\/blog_category?post=2231"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}