{"id":2268,"date":"2025-12-03T09:46:51","date_gmt":"2025-12-03T01:46:51","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=2268"},"modified":"2025-12-03T09:49:19","modified_gmt":"2025-12-03T01:49:19","slug":"br-poe-vt-poe-network-surge-protector","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/ko\/product\/br-poe-vt-poe-network-surge-protector\/","title":{"rendered":"BR-POE-VT POE \ub124\ud2b8\uc6cc\ud06c \uc11c\uc9c0 \ubcf4\ud638\uae30"},"content":{"rendered":"<h3>\uc124\uba85<\/h3><p><strong>\uc81c\ud488 \ud2b9\uc131:<\/strong><\/p>\n<table style=\"width: 70.6496%; height: 696px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\" style=\"height: 24px;\">\n<td style=\"height: 24px;\"><strong>\uc0ac\uc591<\/strong><\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\"><strong>BR-POE-VT<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ud14c\uc2a4\ud2b8 \ud45c\uc900<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">IEC 61643-21<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">SPD \ud074\ub798\uc2a4<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">TYPE2 P1<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uacf5\uce6d \uc804\uc555<\/td>\n<td style=\"height: 24px;\">\uc720\uc5d4<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">5V\/48V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ucd5c\ub300. \uc5f0\uc18d \uc791\ub3d9 d.c. \uc804\uc555<\/td>\n<td style=\"height: 24px;\">UC<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">48V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ucd5c\ub300. \uc5f0\uc18d \uc791\ub3d9 a.c. \uc804\uc555<\/td>\n<td style=\"height: 24px;\">UC<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">34V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ucd5c\ub300. \uc5f0\uc18d \uc791\ub3d9 d.c. \uc804\uc555\uc30d\uc30d(PoE)<\/td>\n<td style=\"height: 24px;\">UC<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">57V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uacf5\uce6d \uc804\ub958<\/td>\n<td style=\"height: 24px;\">\uc77c\ub9ac\ub178\uc774<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">1A<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">D1 \ud68c\uc120\ub2f9 \ub099\ub8b0 \uc804\ub958(10\/350\u03bcs)<\/td>\n<td style=\"height: 24px;\">\uc784\ud504<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">0.5kA<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">C2 \uacf5\uce6d \ubc29\uc804 \uc804\ub958(8\/20\u03bcs) \ub77c\uc778-\ub77c\uc778<\/td>\n<td style=\"height: 24px;\">~ \uc548\uc5d0<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">150a<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">C2 \uacf5\uce6d \ubc29\uc804 \uc804\ub958(8\/20\u03bcs) \ub77c\uc778-PG<\/td>\n<td style=\"height: 24px;\">~ \uc548\uc5d0<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">3kA<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ucd5c\ub300 \ubc29\uc804 \uc804\ub958<\/td>\n<td style=\"height: 24px;\">\uc544\uc774\ub9e5\uc2a4<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">5kA<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"height: 48px;\">C2 \uacf5\uce6d \ubc29\uc804 \uc804\ub958(8\/20\u03bcs) \uc30d\uc30d(PoE)<\/td>\n<td style=\"height: 48px;\">~ \uc548\uc5d0<\/td>\n<td style=\"height: 48px;\" align=\"center\" valign=\"middle\">150a<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">In C2\uc5d0 \ub300\ud55c \uc804\uc555 \ubcf4\ud638 \uc218\uc900 \uc30d\uc30d<\/td>\n<td style=\"height: 24px;\">\uc704\ub85c<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">180V \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">In C2\uc6a9 \uc804\uc555 \ubcf4\ud638 \ub808\ubca8 \ub77c\uc778-PG<\/td>\n<td style=\"height: 24px;\">\uc704\ub85c<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">500V \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">In C2(POE)\uc6a9 \uc804\uc555 \ubcf4\ud638 \ub808\ubca8 \ub77c\uc778-\ub77c\uc778<\/td>\n<td style=\"height: 24px;\">\uc704\ub85c<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">600V \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">250MHz\uc5d0\uc11c\uc758 \uc0bd\uc785 \uc190\uc2e4<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">3dB \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc6a9\ub7c9 \ub77c\uc778-\ub77c\uc778<\/td>\n<td style=\"height: 24px;\">C<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">30pF \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc6a9\ub7c9\uc120-PG<\/td>\n<td style=\"height: 24px;\">C<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">25pF \uc774\ud558<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc791\ub3d9 \uc628\ub3c4 \ubc94\uc704<\/td>\n<td style=\"height: 24px;\">\ud654<\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">-40\u2103~80\u2103<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"height: 48px;\">\uc7a5\ucc29\uc6a9<\/td>\n<td style=\"height: 48px;\"><\/td>\n<td style=\"height: 48px;\" align=\"center\" valign=\"middle\">35mm DIN \ub808\uc77c \uc561\uc138\uc11c\ub9ac. EN 60715\uc5d0 \ub530\ub984<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc5f0\uacb0(\uc785\ub825\/\ucd9c\ub825)<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">RJ45 \uc18c\ucf13\/RJ45 \uc18c\ucf13<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uace0\uc815<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">1\/2\/3\/4\/5\/6\/7\/8<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc804\uc1a1 \uc18d\ub3c4<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">1000Mbps<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc778\ud074\ub85c\uc800 \uc7ac\ub8cc<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">\uc54c\ub8e8\ubbf8\ub284 \ud569\uae08<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\ubcf4\ud638 \uc218\uc900(\ud50c\ub7ec\uadf8\uc778)<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">IP20<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">\uc8fc\ubb38 \ucf54\ub4dc<\/td>\n<td style=\"height: 24px;\"><\/td>\n<td style=\"height: 24px;\" align=\"center\" valign=\"middle\">D9162<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\ud2b9\uc9d5:<\/strong><\/p>\n<p>POE\uc6a9 SPD\ub294 IEC 61643-21 \ud45c\uc900\uc5d0 \ub530\ub77c \uc124\uacc4\ub418\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<p>Fast \/ Gigabit Ethernet \ud658\uacbd \ubaa8\ub450\uc5d0\uc11c POE \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc744 \uc9c0\uc6d0\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc9c0\uc6d0 \uc804\uc555 \u2013 48Vdc \/ 34Vac.<\/p>\n<p>\ud68c\ub85c \ubcf4\ud638.<\/p>\n<p>\ud604\uc7ac \ubcf4\ud638.<\/p>\n<p>\ud5a5\uc0c1\ub41c \uc11c\uc9c0 \ubcf4\ud638.<\/p>\n<p>35mm DIN \ub808\uc77c\uc5d0 \uc7a5\ucc29\uc6a9. EN 60715\uc5d0 \ub530\ub984<\/p>\n<p>\uc7a5\ube44\uac00 \uc81c\ub300\ub85c \uc791\ub3d9\ud558\ub294\uc9c0 \ud6a8\uacfc\uc801\uc73c\ub85c \ud655\uc778\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ubc88\uac1c \ubc0f \uc804\uae30 \uc2a4\uc704\uce6d \uc774\ubca4\ud2b8\ub85c \uc778\ud55c \uc77c\uc2dc\uc801\uc778 \uacfc\uc804\uc555 \ub610\ub294 \uc11c\uc9c0\ub85c\ubd80\ud130 \uc2dc\uc2a4\ud15c\uc744 \ubcf4\ud638\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc0c1\ub300 \uc2b5\ub3c4: 5%-95%.<\/p>\n<p>\uc791\ub3d9 \uc628\ub3c4: -40\u2103~+80\u2103.<\/p>\n<p>\ub300\uae30\uc555: 70kPa~106kPa.<\/p>\n<p>\uc774 \uc81c\ud488 \uc2dc\ub9ac\uc988\ub294 \ub0ae\uc740 \ud074\ub7a8\ud551 \uc804\uc555\uc73c\ub85c \uc791\ub3d9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ub9ce\uc740 \uc591\uc758 \uacfc\ub3c4 \uc5d0\ub108\uc9c0\ub97c \ud761\uc218\ud558\uc5ec \uc804\uc790 \uc7a5\ube44\ub97c \ubcf4\ud638\ud558\uace0 \uc7a5\uae30\uc801\uc778 \uc2dc\uc2a4\ud15c \uc2e0\ub8b0\uc131\uc744 \uc9c0\uc6d0\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc774 \ubcf4\ud638 \uc7a5\uce58\ub294 \ub77c\uc778 \uc778\ub355\ud134\uc2a4 \ub610\ub294 \ub300\uc9c0\uc758 \uacfc\uc804\uc555\uc5d0 \uc758\ud574 \uc190\uc0c1\ub418\uae30 \uc26c\uc6b4 \uc7a5\ube44\ub97c \ubcf4\ud638\ud558\uae30 \uc704\ud574 \uac1c\ubc1c\ub418\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ucd5c\uace0 \ub4f1\uae09\uc758 \uc6d0\uc790\uc7ac\ub97c \uc0ac\uc6a9\ud558\uc5ec \uc81c\uc791\ub41c \uc11c\uc9c0 \ubcf4\ud638 \uc7a5\uce58\uac00 \ub0b4\uc7a5\ub418\uc5b4 \uc788\uc5b4 \ub370\uc774\ud130 \uc190\uc2e4 \uc5c6\uc774 \uc548\uc804\ud558\uac8c \uc804\uc1a1\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p><strong>\uc560\ud50c\ub9ac\ucf00\uc774\uc158:<\/strong><\/p>\n<p>POE PoE(Power Over Ethernet) \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc6a9<\/p>\n<p>\uc801\uc808\ud55c \uc11c\uc9c0 \ubcf4\ud638 \ud558\ub4dc\uc6e8\uc5b4 \ubc0f \uc124\uce58 \uad00\ud589\uc744 \ud1b5\ud574 \uc190\uc0c1\uc744 \uc81c\ud55c\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub354\ub137 \ucf00\uc774\ube14\uc758 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uc5d0 \ub110\ub9ac \uc0ac\uc6a9\ub418\ub294 \ubb34\uc120 \ube0c\ub9ac\uc9c0, \ub124\ud2b8\uc6cc\ud06c \uce74\uba54\ub77c \ubc0f \uae30\ud0c0 \ub124\ud2b8\uc6cc\ud06c \uc7a5\ube44.<\/p>\n<p>\uc774\ub354\ub137\uc73c\ub85c \uc804\uc6d0\uc774 \uacf5\uae09\ub418\ub294 \ub124\ud2b8\uc6cc\ud06c \uc7a5\uce58\ub97c \ubcf4\ud638\ud558\ub294 \ub370 \uc774\uc0c1\uc801<\/p>\n<p>POE \uc911\uc559 \uc9d1\uc911\uc2dd \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 HD \ub514\uc9c0\ud138 \uac10\uc2dc \uce74\uba54\ub77c, \uad50\ud658\uae30 \ubc0f \uc9d1\uc911 \uc7a5\uce58\uc5d0 \uc801\ud569\ud569\ub2c8\ub2e4.<\/p>\n<p>POE \uc11c\uc9c0 \ubcf4\ud638\uae30\ub294 POE(Power over Ethernet) \uc9c0\uc6d0 \uc7a5\uce58\uc5d0\uc11c \uc0dd\uc131\ub41c \uc11c\uc9c0\ub85c\ubd80\ud130 \ub124\ud2b8\uc6cc\ud06c \uc7a5\uce58\ub97c \ubcf4\ud638\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc2a4\ud30c\uc774\ud06c\ub85c\ubd80\ud130 \uc804\uc790 \uc7a5\uce58\ub97c \ubcf4\ud638\ud558\uc2ed\uc2dc\uc624.<\/p>\n<p>\uc804\uae30\uc801 \uacfc\ub3c4 \ud604\uc0c1\uc73c\ub85c\ubd80\ud130 \ubcf4\ud638\ud569\ub2c8\ub2e4.<\/p>\n<p>\ub099\ub8b0 \ubc0f \uc11c\uc9c0\ub85c \uc778\ud55c \uc190\uc0c1\uc73c\ub85c\ubd80\ud130 \uc774\ub354\ub137 \uc7a5\uce58\ub97c \ubcf4\ud638\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc11c\ubc84 \uc7a5\ube44, \ub77c\uc6b0\ud130, \uc6cc\ud06c\uc2a4\ud14c\uc774\uc158(\uc778\ud2b8\ub77c\ub137) HUB \ubc0f \ubcf4\ub4dc \ubc34\ub4dc\uc5d0 \ub110\ub9ac \uc0ac\uc6a9\ub429\ub2c8\ub2e4.<\/p>\n<p>LAN\/\uc774\ub354\ub137 \ub124\ud2b8\uc6cc\ud06c\/\uc2a4\uc704\uce58\ub97c \uc815\uc804\uae30 \ubc29\uc804 \ubc0f \uc804\uc555 \uc11c\uc9c0\ub85c \uc778\ud574 \uc190\uc0c1\ub418\uc9c0 \uc54a\ub3c4\ub85d \ubcf4\ud638\ud558\uc2ed\uc2dc\uc624.<\/p>\n<p>\ub099\ub8b0 \ub610\ub294 \ub0b4\ubd80 \uc2dc\uc2a4\ud15c\uc73c\ub85c \uc778\ud55c \uc11c\uc9c0 \ubc0f \uacfc\uc804\uc555\uc73c\ub85c\ubd80\ud130 \ud3ec\ud2b8\ub97c \ubcf4\ud638\ud558\uae30 \uc704\ud574 \ubb34\uc120 \ube0c\ub9ac\uc9c0\uc5d0 \uc801\ud569\ud569\ub2c8\ub2e4.<\/p>\n<div>\ub370\uc774\ud130 \ub77c\uc778 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc758 \uacbd\uc6b0 \ubc88\uac1c \ubc0f \uae30\ud0c0 \uac15\ud55c \uc804\ub825\uc73c\ub85c \uc778\ud574 \ubc1c\uc0dd\ud560 \uc218 \uc788\ub294 \uc5d0\ub108\uc9c0 \uc2a4\ud30c\uc774\ud06c\ub85c \uc778\ud55c \uc190\uc0c1\uc744 \ubc29\uc9c0\ud558\ub294 \ub370 \ub3c4\uc6c0\uc774 \ub429\ub2c8\ub2e4.<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1858\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1976\" height=\"541\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe.jpg 1976w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe-300x82.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe-1024x280.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe-768x210.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-POE-M-\u539f\u7406\u56fe-1536x421.jpg 1536w\" sizes=\"auto, (max-width: 1976px) 100vw, 1976px\" \/><\/div>\n<div><\/div>","protected":false},"parent":0,"menu_order":28,"template":"","meta":{"_acf_changed":false},"product_category":[30],"class_list":["post-2268","product","type-product","status-publish","hentry","product_category-ethernet-surge-protection-devices"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/ko\/wp-json\/wp\/v2\/product\/2268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/ko\/wp-json\/wp\/v2\/media?parent=2268"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/ko\/wp-json\/wp\/v2\/product_category?post=2268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}