{"id":992,"date":"2024-09-04T14:18:01","date_gmt":"2024-09-04T06:18:01","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=992"},"modified":"2025-04-08T13:47:14","modified_gmt":"2025-04-08T05:47:14","slug":"br-12-5m-4p-12-5ka-type-12-surge-protective-device-for-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/it\/product\/br-12-5m-4p-12-5ka-type-12-surge-protective-device-for-tns\/","title":{"rendered":"BR-12.5M Dispositivo di protezione da sovratensione 4P 12,5 kA Tipo 1+2 per TNS"},"content":{"rendered":"<h3>Descrizione<\/h3><p><strong>Caratteristiche del prodotto:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Specifica<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-12.5M 150 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-12.5M 275 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-12.5M 320 4P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classificazione SPD secondo EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classificazione SPD secondo IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Massimo. funzionamento continuo c.a. voltaggio<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corrente impulsiva di fulmine (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corrente di scarica nominale (8\/20\u03bcs)<\/td>\n<td height=\"32\">In<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Massimo. corrente di scarica (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">60kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">60kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">60kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Energia specifica<\/td>\n<td height=\"32\">W\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">39kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">39kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">39kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Livello di protezione della tensione<\/td>\n<td height=\"32\">Su<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22640,8kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corrente nominale di cortocircuito c.a.<\/td>\n<td height=\"32\">Isccr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA efficace<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA efficace<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA efficace<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Massimo. fusibile di riserva<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">125A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">125A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">125A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Resistenza TOV a sovratensione temporanea<\/td>\n<td height=\"32\">UT(L-N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">180 V\/5 secondi.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 sec.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 secondi.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Guasto TOV-safe per sovratensione temporanea<\/td>\n<td height=\"32\">UT(L-N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/120 min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440 V\/120 min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520 V\/120 min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tempo di risposta<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Intervallo di temperatura operativa<\/td>\n<td height=\"32\">Tu<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<\/tr>\n<tr>\n<td>Indicazione dello stato di funzionamento\/guasto<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">verde\/rosso<\/td>\n<td style=\"text-align: center;\">verde\/rosso<\/td>\n<td style=\"text-align: center;\">verde\/rosso<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Area della sezione trasversale (Min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Area della sezione trasversale (max.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Per il montaggio<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Guida DIN da 35 mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Materiale della custodia<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termoplastico UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Grado di protezione<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Codice ordine<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18411<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18413<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18415<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Codice d'ordine (Con segnalazione remota)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18412<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18414<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18416<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Caratteristiche:<\/strong><\/p>\n<p>Il tipo 1+2, T1+T2, B+C, I+II, Iimp 12,5 kA \u00e8 sviluppato come la migliore soluzione disponibile per proteggere l'ingresso di servizio nei siti industriali.<\/p>\n<p>\u00c8 progettato per soddisfare tutte le vostre esigenze per qualsiasi installazione a bassa tensione.<\/p>\n<p>\u00c8 facile da installare in qualsiasi quadro di distribuzione o armadio di controllo standardizzato.<\/p>\n<p>Ha una forma d'onda di corrente 10\/350 \u03bcs.<\/p>\n<p>\u00c8 dotato di un dispositivo di disconnessione termica e fornisce indicatori di guasto in tempo reale consentendo cos\u00ec la completa sicurezza operativa.<\/p>\n<p>Utilizzare il modulo collegabile configurato, la manutenzione \u00e8 semplice<\/p>\n<p>Montabile su guida Din (35 mm)<\/p>\n<p>Ha le caratteristiche di bassa pressione residua, reazione sensibile, prestazioni stabili, lavoro affidabile e cos\u00ec via.<\/p>\n<p>Con contatto di segnalazione remota per dispositivo di controllo.<\/p>\n<p>\u00c8 progettato secondo GB18802.1 IEC61643-11<\/p>\n<p>Indicazione di guasto tramite segno rosso nella finestra di ispezione.<\/p>\n<p><strong>Applicazione:<\/strong><\/p>\n<p>Per evitare che le apparecchiature di alimentazione vengano danneggiate da sovratensioni e fulmini.<\/p>\n<p>Utilizzo su edifici in applicazioni in cui \u00e8 installato un sistema di protezione contro i fulmini esterno, solitamente installato all'ingresso di servizio.<\/p>\n<p>Ampiamente utilizzato nel lato bassa tensione del trasformatore come prima protezione dell'alimentazione.<\/p>\n<p><strong>Installazione:<\/strong><\/p>\n<p>Installato nelle distribuzioni a bassa tensione al confine delle zone LPZ 0\u2013LPZ 1 e superiori per prevenire effetti di sovratensione indotti durante un fulmine e per prevenire sovratensioni di commutazione.<\/p>\n<p>Installare nell'armadio\/scatola di distribuzione principale dell'armadio a bassa tensione e nell'armadio della linea di ingresso.<\/p>\n<p>Consigliato per quadri di distribuzione principali.<\/p>\n<p>Durante l'installazione, collegarsi secondo lo schema di installazione, dove L1, L2 e L3 sono le linee di fase, N \u00e8 la linea zero e PE \u00e8 la linea di terra.<\/p>\n<p>La messa a terra deve essere conforme ai requisiti delle specifiche di protezione contro i fulmini.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1638\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-4P-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":97,"template":"","meta":{"_acf_changed":false},"product_category":[21],"class_list":["post-992","product","type-product","status-publish","hentry","product_category-type-1-2-lightning-surge-arrester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/it\/wp-json\/wp\/v2\/product\/992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/it\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/it\/wp-json\/wp\/v2\/media?parent=992"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/it\/wp-json\/wp\/v2\/product_category?post=992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}