Product characteristics:
Specification | CCTV-21P-48 | CCTV-21P-230 | |
Test standards | IEC 61643-21 | IEC 61643-21 | |
Max. continuous operating d.c. voltage (RJ45) | Uc | 6V | 6V |
Max. continuous operating a.c. voltage (RJ45) | Uc | 4V | 4V |
Max. continuous operating a.c. voltage (power) | Uc | 60V | 275V |
Nominal current | IL | 0.5A | 0.5A |
C2 Norminal discharge current (8/20μs) | In | 5kA | 5kA |
C2 Max. discharge current (8/20μs) | Imax | 10kA | 10kA |
Voltage protection level [line-line/shield] (RJ45) | Up | ≤30V | ≤30V |
Voltage protection level [line/shield-PG] (RJ45) | Up | ≤500V | ≤500V |
Voltage protection level (power) | Up | ≤200V | ≤1.2kV |
Response time [line-line/shield] | tA | ≤1ns | ≤1ns |
Response time [line/shield-PG] | tA | ≤100ns | ≤100ns |
Operating temperature range | Tu | -40℃…+80℃ | -40℃…+80℃ |
Connection input/output RJ45/Power | RJ45/Terminal block | RJ45/Terminal block | |
Bandwidth | 30Mbps | 30Mbps | |
Insertion Loss | ≤0.3dB | ≤0.3dB | |
Enclosure material | Thermal plastic | Thermal plastic | |
Degree of protection | IP20 | IP20 | |
Order Code | D9052 | D9053 |
Features:
High-End Spec Surge Protection Devices.
Nominal current: 0.5A.
C2 Max. discharge current (8/20us): 10kA.
Line to line, line to ground protection.
Operating temperature:-40℃~+80℃.
Designed according to IEC 61643-21 standards.
It’s a new generation of CCTV signal protection products.
Application:
SPDs for CCTV is mainly used for supervisory control system, preventing product from lightning strike and surge.
Offer surge protection for almost any products application in power, instrumentations and controls, network and data lines, coax and etc.
For Radio Antennas, GPS Antennas, CATV, CCTV and Satellite TV.