{"id":2249,"date":"2025-11-21T09:14:19","date_gmt":"2025-11-21T01:14:19","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2249"},"modified":"2025-11-19T15:42:39","modified_gmt":"2025-11-19T07:42:39","slug":"how-to-select-appropriate-ka-rating-for-ac-surge-protection-device","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/id\/blog\/how-to-select-appropriate-ka-rating-for-ac-surge-protection-device\/","title":{"rendered":"Cara Memilih Peringkat Ka yang Sesuai Untuk Perangkat Perlindungan Lonjakan AC"},"content":{"rendered":"<div>Dengan pasar yang dibanjiri pelindung lonjakan arus mulai dari SPD Tipe 2 10KA dan 40KA hingga 200KA, memilih model yang tepat dapat membingungkan.<\/div>\r\n<div><\/div>\r\n<div>Panduan komprehensif ini akan mengungkap misteri kA dan memberdayakan Anda untuk memilih yang sempurna <a href=\"https:\/\/www.britecelectric.com\/id\/product-category\/ac-power-surge-protection\/\">Perangkat perlindungan lonjakan arus AC<\/a> untuk aplikasi Anda.<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/id\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" rel=\"attachment wp-att-1616\"><img class=\"alignnone size-full wp-image-1616\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-1.jpg\" alt=\"BR-25M 1+1 Tipe 1 25kA Surge Arrester Untuk TT Dan TNS\" width=\"800\" \/><\/a><\/div>\r\n<h2>Pahami peringkat kA pelindung lonjakan arus<\/h2>\r\n<div>Nilai kA pelindung lonjakan arus menunjukkan kemampuannya untuk menyerap dan memotong energi lonjakan arus dari peralatan Anda. Ini diukur dalam kiloamper (kA) dan menunjukkan arus lonjakan maksimum yang dapat ditahan perangkat tanpa kegagalan dalam jumlah siklus tertentu.<\/div>\r\n<div><\/div>\r\n<div>You can think of it as the size of a \"bucket\" to catch a sudden downpour of electrical energy. A small bucket (10KA surge protector) might be sufficient for a light rain, but a torrential downpour requires a much larger bucket (80KA surge protector or higher).<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2>Cara Memilih Peringkat KA yang Sesuai Untuk Perangkat Perlindungan Lonjakan AC<\/h2>\r\nMemilih KA yang tepat adalah proses sistematis yang melibatkan penilaian risiko, lokasi pemasangan, dan kepatuhan terhadap peraturan.\r\n<h3>Penilaian Risiko<\/h3>\r\n<div>Pertama, nilai paparan risiko lonjakan di lingkungan Anda. Faktor kuncinya meliputi:<\/div>\r\n<div><\/div>\r\n<div><strong>Lokasi geografis:<\/strong> Apakah Anda berlokasi di daerah yang rawan petir (misalnya pedesaan, pegunungan)?<\/div>\r\n<div><\/div>\r\n<div><strong>Jenis fasilitas:<\/strong> Apakah itu bangunan tempat tinggal, gedung perkantoran komersial, rumah sakit, atau pabrik industri? Infrastruktur penting memerlukan tingkat perlindungan yang lebih tinggi.<\/div>\r\n<div><\/div>\r\n<div><strong>Jarak dari sumber listrik:<\/strong> Lokasi di dekat trafo atau saluran listrik lebih rentan terhadap lonjakan arus listrik.<\/div>\r\n<h3>Tentukan lokasi pemasangan SPD<\/h3>\r\nThe installation location of the surge protector (SPD) in your electrical system directly determines the required kA nominal value. This is typically categorized by \"Type\":\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/id\/product\/br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c\/\" rel=\"attachment wp-att-1876\"><img class=\"alignnone size-full wp-image-1876\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-1.jpg\" alt=\"Penahan Lonjakan BR-25GR 3P Tipe 1 25kA untuk TN-C\" width=\"800\" \/><\/a>\r\n\r\n<strong>Tipe 1 (Perlindungan Tingkat 1):<\/strong> Dipasang di kabinet distribusi utama, tempat listrik masuk ke dalam gedung. Harus mampu menahan lonjakan terbesar, seperti sambaran petir langsung. SPD 40KA, pelindung lonjakan arus 60KA, atau bahkan SPD 100KA biasanya digunakan di sini.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/id\/product\/br-20-31-type-2-20ka-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1717\"><img class=\"alignnone size-full wp-image-1717\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-31-1.jpg\" alt=\"Perangkat Pelindung Lonjakan BR-20 3+1 Tipe 2 20kA Untuk TT Dan TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Tipe 2 (Perlindungan Tingkat 2):<\/strong> Dipasang di kotak distribusi untuk melindungi peralatan hilir. Ini adalah jenis perlindungan seluruh bangunan yang paling umum. SPD 40KA Tipe 2 adalah pilihan yang populer dan tangguh dalam banyak aplikasi.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/id\/product\/br-40dp-31-40ka-compact-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1783\"><img class=\"alignnone size-full wp-image-1783\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40DP-31.jpg\" alt=\"BR-40DP 3+1 40kA Perangkat Pelindung Lonjakan Kompak Untuk TT Dan TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Tipe 3 (Perlindungan Tingkat 3):<\/strong> Dipasang di ujung peralatan untuk memberikan perlindungan yang baik untuk peralatan paling sensitif, seperti server dan perangkat medis. Mereka biasanya digunakan bersama dengan dua jenis SPD pertama, dengan persyaratan kA yang lebih rendah.\r\n<h3>Tinjau dan patuhi standar dan spesifikasi setempat<\/h3>\r\nCompliance with local electrical codes is crucial. For example, in China, GB 50057 \"Code for Design of Lightning Protection of Buildings\" and GB 50343 \"Technical Code for Lightning Protection of Electronic Information Systems in Buildings\" must be followed. These standards typically specify the minimum kA requirements for SPDs at different installation points based on factors such as building type and thunderstorm day zoning.\r\n<h3><\/h3>\r\n<h3>Pengambilan keputusan dan pemilihan model yang komprehensif<\/h3>\r\n<strong>Berisiko tinggi\/Pintu Masuk Utama:<\/strong> Pilih SPD Tipe 1 dengan kA tinggi, seperti SPD 60KA atau 100KA.\r\n\r\n<strong>Kotak Distribusi\/Risiko Menengah:<\/strong> Pilih SPD Tipe 2 yang andal, seperti SPD Tipe 2 25KA atau 40KA.\r\n\r\n<strong>Perlindungan Baik:<\/strong> Pilih SPD Tipe 3 untuk peralatan tertentu.\r\n\r\n&nbsp;\r\n<h2>Skenario Umum dan Panduan Pemilihan kA<\/h2>\r\n<h3>Pelindung Lonjakan Arus 10KA<\/h3>\r\nCocok untuk rumah kecil dan apartemen di kawasan berisiko rendah, atau sebagai perlindungan level 3 setelah Tipe 2.\r\n<h3>Pelindung Lonjakan Arus 20KA<\/h3>\r\nPelindung lonjakan arus 20KA dapat digunakan untuk perlindungan sekunder di pemukiman perkotaan biasa, toko kecil, dan kantor, menjadikannya pilihan yang hemat biaya.\r\n<h3>SPD 40KA<\/h3>\r\nSPD 40KA cocok untuk konfigurasi standar perlindungan sekunder pada sebagian besar bangunan komersial, pabrik berukuran sedang, dan bangunan tempat tinggal bertingkat tinggi di perkotaan, memberikan perlindungan yang sangat baik.\r\n<h3>Pelindung Lonjakan Arus 60KA<\/h3>\r\nSkenario yang berlaku: Kotak distribusi utama (tipe sekunder atau gabungan) pada bangunan di area dengan risiko petir sedang hingga tinggi, atau lingkungan industri.\r\n<h3>Pelindung Lonjakan Arus 80KA<\/h3>\r\nPelindung lonjakan arus 80KA digunakan di kotak distribusi utama di daerah berisiko tinggi, daerah pedesaan, dan bangunan terpisah, sehingga memberikan kapasitas pelepasan arus yang lebih kuat.\r\n<h3>SPD 100KA<\/h3>\r\nSPD 100KA digunakan untuk pintu masuk utama fasilitas industri besar, rumah sakit, pusat data, atau sebagai perlindungan Tipe 1 untuk bangunan penting.\r\n<h3>Pelindung Lonjakan Arus 200KA<\/h3>\r\nDigunakan untuk melindungi pintu masuk utama ke area badai petir, infrastruktur penting (seperti bandara dan pabrik kimia), dan stasiun pangkalan komunikasi.\r\n<h2>Faktor-faktor yang mempengaruhi pemilihan nilai kA<\/h2>\r\n<strong>Tingkat Perlindungan Tegangan (Naik):<\/strong> Parameter ini mencerminkan tegangan aktual yang akan dialami peralatan secara lebih langsung dibandingkan nilai kA. Saat memilih SPD, pastikan nilai Naiknya lebih rendah dari nilai tegangan ketahanan peralatan yang dilindungi.\r\n\r\n<strong>Pemutus Sirkuit Cadangan:<\/strong> Pastikan kapasitas pemutus arus atau sekring yang digunakan dengan SPD sesuai untuk memutuskan sambungan sirkuit dengan aman jika terjadi kegagalan SPD.\r\n\r\n<strong>Indikator Status Modul:<\/strong> Pilih SPD dengan sinyal jarak jauh atau alarm visual (seperti perubahan warna jendela) untuk memfasilitasi penilaian status cepat oleh personel pemeliharaan.\r\n\r\n&nbsp;\r\n<h2>Pertanyaan Umum:<\/h2>\r\n<strong>Why isn't higher kA always better?<\/strong>\r\n\r\nAn excessively high kA value may lead to a correspondingly high residual voltage (protection level) in the SPD, resulting in insufficient protection for delicate equipment. Furthermore, high kASPD values \u200b\u200bare more expensive and may be larger. The principle of \"sufficient with a margin\" should be followed.\r\n\r\n<strong>What's the difference between\u00a0 10KA Surge Protector and a 40KA Type 2 SPD?<\/strong>\r\n\r\nPerbedaan utamanya terletak pada kapasitas debit saat ini. SPD Tipe 2 40KA dapat menyerap dan melepaskan arus lonjakan hingga 4 kali lebih besar dari pelindung lonjakan arus 10KA, sehingga memberikan perlindungan yang lebih andal untuk bangunan atau peralatan yang lebih besar dan kritis, dan biasanya memiliki masa pakai lebih lama.\r\n\r\n<strong>Apakah peringkat kA SPD untuk mode tunggal atau jumlah semua fase?<\/strong>\r\n\r\nKA biasanya mengacu pada operasi mode tunggal (kutub tunggal). Misalnya, SPD satu fasa yang diberi nilai nominal 40kA berarti masing-masing kutub L dan N dapat menangani lonjakan sebesar 40kA. SPD tiga fase 40kA berarti masing-masing kutub L1, L2, L3, dan N dapat menangani 40kA.\r\n\r\n<strong>Bagaimana cara menentukan apakah SPD saya gagal?<\/strong>\r\n\r\nKebanyakan SPD modern dilengkapi dengan jendela indikator visual (biasanya hijau untuk pengoperasian normal dan merah\/hitam untuk kegagalan) atau kontak alarm jarak jauh. Memeriksa indikator-indikator ini secara teratur merupakan bagian penting dari pemeliharaan.\r\n\r\n<strong>Bisakah saya meningkatkan kapasitas kA dengan menghubungkan SPD baru secara paralel dengan yang lama?<\/strong>\r\n\r\nHal ini sangat tidak dianjurkan. Karena sedikit perbedaan dalam karakteristik perangkat, perangkat tersebut tidak dapat mendistribusikan arus lonjakan secara merata, yang dapat menyebabkan salah satu perangkat gagal terlebih dahulu, sehingga menimbulkan bahaya keselamatan. Pendekatan yang benar adalah dengan menggantinya dengan SPD baru dengan kapasitas kA yang lebih tinggi.\r\n\r\n&nbsp;\r\n<h2>Kesimpulan<\/h2>\r\n<div>Melalui penilaian sistematis, mulai dari memahami risiko badai petir di wilayah Anda hingga menentukan apakah SPD harus dipasang di saluran masuk utama (seperti pelindung lonjakan arus 80KA) atau di kotak sub-distribusi (SPD 40KA Tipe 2), Anda dapat membuat keputusan yang tepat.<\/div>","protected":false},"featured_media":1616,"parent":0,"menu_order":104,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2249","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"This comprehensive guide will unravel the mysteries of kA and empower you to select the perfect AC surge protection device for your application.","txt":"<div>With a market flooded with surge protectors ranging from 10KA and 40KA Type 2 SPDs to even 200KA, choosing the right model can be confusing.<\/div>\r\n<div><\/div>\r\n<div>This comprehensive guide will unravel the mysteries of kA and empower you to select the perfect <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/\">AC surge protection device<\/a> for your application.<\/div>\r\n<div><\/div>\r\n<div><a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" rel=\"attachment wp-att-1616\"><img class=\"alignnone size-full wp-image-1616\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-1.jpg\" alt=\"BR-25M 1+1 Type 1 25kA Surge Arrester For TT And TNS\" width=\"800\" \/><\/a><\/div>\r\n<h2>Understand the kA rating of surge protectors<\/h2>\r\n<div>The kA value of a surge protector represents its ability to absorb and bypass surge energy from your equipment. It is measured in kiloamperes (kA) and indicates the maximum surge current the device can withstand without failure within a specified number of cycles.<\/div>\r\n<div><\/div>\r\n<div>You can think of it as the size of a \"bucket\" to catch a sudden downpour of electrical energy. A small bucket (10KA surge protector) might be sufficient for a light rain, but a torrential downpour requires a much larger bucket (80KA surge protector or higher).<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<h2>How To Select Appropriate KA Rating For AC Surge Protection Device<\/h2>\r\nChoosing the right kA is a systematic process that involves risk assessment, installation location, and regulatory compliance.\r\n<h3>Risk Assessment<\/h3>\r\n<div>First, assess the surge risk exposure of your environment. Key factors include:<\/div>\r\n<div><\/div>\r\n<div><strong>Geographic location:<\/strong> Are you located in a high-lightning-prone area (e.g., rural, mountainous)?<\/div>\r\n<div><\/div>\r\n<div><strong>Facilities type:<\/strong> Is it a residential building, commercial office building, hospital, or industrial plant? Critical infrastructure requires a higher level of protection.<\/div>\r\n<div><\/div>\r\n<div><strong>Distance from power sources:<\/strong> Locations near transformers or power lines are more susceptible to switching surges.<\/div>\r\n<h3>Determine the installation location of the SPD<\/h3>\r\nThe installation location of the surge protector (SPD) in your electrical system directly determines the required kA nominal value. This is typically categorized by \"Type\":\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25gr-3p-type-1-25ka-surge-arrester-for-tn-c\/\" rel=\"attachment wp-att-1876\"><img class=\"alignnone size-full wp-image-1876\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25GR-3P-1.jpg\" alt=\"BR-25GR 3P Type 1 25kA Surge Arrester for TN-C\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 1 (Level 1 Protection):<\/strong> Installed in the main distribution cabinet, where power enters the building. It must be able to withstand the largest surges, such as direct lightning strikes. 40KA SPDs, 60KA surge protectors, or even 100KA SPDs are commonly used here.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-20-31-type-2-20ka-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1717\"><img class=\"alignnone size-full wp-image-1717\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-20-31-1.jpg\" alt=\"BR-20 3+1 Type 2 20kA Surge Protective Device For TT And TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 2 (Level 2 Protection):<\/strong> Installed in the distribution box to protect downstream equipment. This is the most common type of whole-building protection. 40KA Type 2 SPDs are a popular and robust choice in many applications.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-40dp-31-40ka-compact-surge-protective-device-for-tt-and-tns\/\" rel=\"attachment wp-att-1783\"><img class=\"alignnone size-full wp-image-1783\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-40DP-31.jpg\" alt=\"BR-40DP 3+1 40kA Compact Surge Protective Device For TT And TNS\" width=\"800\" \/><\/a>\r\n\r\n<strong>Type 3 (Level 3 Protection):<\/strong> Installed at the equipment end to provide fine protection for the most sensitive equipment, such as servers and medical devices. They are typically used in conjunction with the first two types of SPDs, with lower kA requirements.\r\n<h3>Review and comply with local standards and specifications<\/h3>\r\nCompliance with local electrical codes is crucial. For example, in China, GB 50057 \"Code for Design of Lightning Protection of Buildings\" and GB 50343 \"Technical Code for Lightning Protection of Electronic Information Systems in Buildings\" must be followed. These standards typically specify the minimum kA requirements for SPDs at different installation points based on factors such as building type and thunderstorm day zoning.\r\n<h3><\/h3>\r\n<h3>Comprehensive decision-making and model selection<\/h3>\r\n<strong>High-risk\/Main Inlet:<\/strong> Select a high-kA Type 1 SPD, such as a 60KA or 100KA SPD.\r\n\r\n<strong>Medium-risk\/Distribution Box:<\/strong> Select a reliable Type 2 SPD, such as a 25KA or 40KA Type 2 SPD.\r\n\r\n<strong>Fine Protection:<\/strong> Select a Type 3 SPD for specific equipment.\r\n\r\n&nbsp;\r\n<h2>Common Scenarios and kA Selection Guide<\/h2>\r\n<h3>10KA Surge Protector<\/h3>\r\nSuitable for small homes and apartments in low-risk areas, or as a level 3 protection after Type 2.\r\n<h3>20KA Surge Protector<\/h3>\r\nThe 20KA surge protector can be used for secondary protection in ordinary urban residences, small shops, and offices, making it a cost-effective choice.\r\n<h3>40KA SPD<\/h3>\r\nThe 40KA SPD is suitable for the secondary protection standard configuration of most commercial buildings, medium-sized factories, and high-rise residential buildings in cities, providing excellent protection.\r\n<h3>60KA Surge Protector<\/h3>\r\nApplicable scenarios: Main distribution boxes (secondary or combined type) in buildings in areas with moderate to high lightning risk, or industrial environments.\r\n<h3>80KA Surge Protector<\/h3>\r\nThe 80KA surge protector is used in the main distribution boxes of high-risk areas, rural areas, and detached buildings, providing stronger current discharge capacity.\r\n<h3>100KA SPD<\/h3>\r\n100KA SPD is used for the main entrances of large industrial facilities, hospitals, data centers, or as Type 1 protection for important buildings.\r\n<h3>200KA Surge Protector<\/h3>\r\nUsed for protection of the main entrances to thunderstorm areas, critical infrastructure (such as airports and chemical plants), and communication base stations.\r\n<h2>Factors influencing the selection of the kA value<\/h2>\r\n<strong>Voltage Protection Level (Up):<\/strong> This parameter reflects the actual voltage the equipment will experience more directly than the kA value. When selecting an SPD, ensure its Up value is lower than the withstand voltage rating of the protected equipment.\r\n\r\n<strong>Backup Circuit Breaker:<\/strong> Ensure the capacity of the circuit breaker or fuse used with the SPD is matched to safely disconnect the circuit in the event of SPD failure.\r\n\r\n<strong>Module Status Indicator:<\/strong> Select an SPD with remote signaling or visual alarms (such as window color changes) to facilitate quick status assessment by maintenance personnel.\r\n\r\n&nbsp;\r\n<h2>FAQ:<\/h2>\r\n<strong>Why isn't higher kA always better?<\/strong>\r\n\r\nAn excessively high kA value may lead to a correspondingly high residual voltage (protection level) in the SPD, resulting in insufficient protection for delicate equipment. Furthermore, high kASPD values \u200b\u200bare more expensive and may be larger. The principle of \"sufficient with a margin\" should be followed.\r\n\r\n<strong>What's the difference between\u00a0 10KA Surge Protector and a 40KA Type 2 SPD?<\/strong>\r\n\r\nThe main difference lies in the current discharge capacity. A 40KA Type 2 SPD can absorb and discharge surge currents up to 4 times greater than a 10KA surge protector, thus providing more reliable protection for larger, more critical buildings or equipment, and typically has a longer service life.\r\n\r\n<strong>Is the kA rating of an SPD for a single mode or the sum of all phases?<\/strong>\r\n\r\nKA typically refers to single-mode (single-pole) operation. For example, a single-phase SPD nominally rated at 40kA means that each of its L and N poles can handle a surge of 40kA. A three-phase 40kA SPD means that each of its L1, L2, L3, and N poles can handle 40kA.\r\n\r\n<strong>How can I determine if my SPD has failed?<\/strong>\r\n\r\nMost modern SPDs are equipped with visual indicator windows (usually green for normal operation and red\/black for failure) or remote alarm contacts. Regularly checking these indicators is a critical part of maintenance.\r\n\r\n<strong>Can I increase the kA capacity by connecting a new SPD in parallel with the old one?<\/strong>\r\n\r\nThis is strongly discouraged. Due to slight differences in device characteristics, they cannot evenly distribute surge current, which may cause one of them to fail first, creating a safety hazard. The correct approach is to replace it with a new SPD with a higher kA capacity.\r\n\r\n&nbsp;\r\n<h2>Conclusion<\/h2>\r\n<div>Through a systematic assessment, from understanding the thunderstorm risk in your area to determining whether an SPD should be installed at the main inlet (such as an 80KA surge protector) or in a sub-distribution box (40KA Type 2 SPD), you can make informed decisions.<\/div>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/blog\/2249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/media\/1616"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/media?parent=2249"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/id\/wp-json\/wp\/v2\/blog_category?post=2249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}