{"id":838,"date":"2023-12-18T15:02:31","date_gmt":"2023-12-18T07:02:31","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=838"},"modified":"2024-09-05T16:32:20","modified_gmt":"2024-09-05T08:32:20","slug":"wind-power-generation-lightning-protection-solutions","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/hu\/blog\/wind-power-generation-lightning-protection-solutions\/","title":{"rendered":"Sz\u00e9lenergia-termel\u00e9si vill\u00e1mv\u00e9delmi megold\u00e1sok"},"content":{"rendered":"A sz\u00e9lenergia-termel\u0151 berendez\u00e9sek hossz\u00fa ideig sz\u00e9les k\u00fclt\u00e9ri ter\u00fcleten helyezkednek el, a vill\u00e1mcsap\u00e1sok val\u00f3sz\u00edn\u0171s\u00e9ge nagyon magas. A sz\u00e9lberendez\u00e9s beruh\u00e1z\u00e1sa nagy, minden vill\u00e1mcsap\u00e1skor k\u00f6lts\u00e9ges a berendez\u00e9s karbantart\u00e1sa. A sz\u00e9lenergia-termel\u00e9sben a t\u00falfesz\u00fclts\u00e9g-v\u00e9d\u0151 t\u0171zgyakoris\u00e1ga csak a m\u00e1sodik a nagysebess\u00e9g\u0171 vas\u00fati \u00e9s kommunik\u00e1ci\u00f3s iparban. Ez\u00e9rt a vill\u00e1mv\u00e9delem a sz\u00e9lenergia els\u0151 sz\u00e1m\u00fa priorit\u00e1sa.\r\n\r\n<strong>1 A sz\u00e9lenergia-termel\u00e9s vill\u00e1mv\u00e9delmi szab\u00e1lyoz\u00e1sa<\/strong>\r\n\r\nA sz\u00e9lenergia-termel\u0151 berendez\u00e9sekben haszn\u00e1lt t\u00falfesz\u00fclts\u00e9g-v\u00e9d\u0151knek meg kell felelni\u00fck az \u00f6sszes al\u00e1bbi el\u0151\u00edr\u00e1snak:\r\n<ul>\r\n \t<li>IEC 62305<\/li>\r\n \t<li>IEC 61312<\/li>\r\n \t<li>IEC 61400-24<\/li>\r\n \t<li>IEC 61643-11<\/li>\r\n<\/ul>\r\n<strong>2 A sz\u00e9lenergia t\u00falfesz\u00fclts\u00e9g-v\u00e9d\u0151k kiv\u00e1laszt\u00e1s\u00e1n\u00e1l figyelembe kell venni az 5 szempontot<\/strong>\r\n<ul>\r\n \t<li>Vill\u00e1mv\u00e9delmi ter\u00fclet (LPZ 0\u20263)<\/li>\r\n \t<li>Az SPD megfelel a teszt\u00e1ram hull\u00e1mform\u00e1j\u00e1nak (8\/20 hull\u00e1m \u00e9s 10\/350 hull\u00e1m stb.)<\/li>\r\n \t<li>Fesz\u00fclts\u00e9gv\u00e9delmi szint (Fel)<\/li>\r\n \t<li>T\u00e1pfesz\u00fclts\u00e9g \u00e9s szabv\u00e1ny (230\/400V \u00e9s 400\/690V rendszerek)<\/li>\r\n<\/ul>\r\n<strong>3 Jellemz\u0151k, amelyekkel a sz\u00e9lenergia t\u00falfesz\u00fclts\u00e9g-v\u00e9d\u0151knek rendelkezni\u00fck kell<\/strong>\r\n\r\nThe motor side, transformer low voltage side and distribution cabinet network side of the wind power generation system must be Class I lightning protection, the continuous working voltage of the Type 1 power surge protector is greater than 690 Vac, which can reasonably protect the normal operation of wind power generation equipment.\r\n\r\nThe Class II power surge protector on the rotor side of the wind turbine is shock-proof and pluggable.","protected":false},"featured_media":839,"parent":0,"menu_order":158,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-838","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Wind power generation equipment is located in a wide outdoor area for a long time, and the probability of lightning strikes is very high.","txt":"Wind power generation equipment is located in a wide outdoor area for a long time, and the probability of lightning strikes is very high. Wind equipment investment is large, each time lightning strikes, the maintenance of the equipment is expensive. In wind power generation, the fire frequency of surge protector is only second to that of high-speed rail and communication industry. Therefore, lightning protection is a top priority for wind power.\r\n\r\n<strong>1 Relevant regulation for lightning protection of wind power generation<\/strong>\r\n\r\nSurge protectors used in wind power generation equipment must comply with all of the following specifications:\r\n<ul>\r\n \t<li>IEC 62305<\/li>\r\n \t<li>IEC 61312<\/li>\r\n \t<li>IEC 61400-24<\/li>\r\n \t<li>IEC 61643-11<\/li>\r\n<\/ul>\r\n<strong>2 The selection of wind power surge protectors needs to take into account the 5 aspect<\/strong>\r\n<ul>\r\n \t<li>Lightning protection area (LPZ 0\u2026 3)<\/li>\r\n \t<li>SPD conforms to the test current waveform (8\/20 wave and 10\/350 wave, etc.)<\/li>\r\n \t<li>Voltage protection level (Up)<\/li>\r\n \t<li>Power supply system voltage and standard (230\/400V and 400\/690 V systems)<\/li>\r\n<\/ul>\r\n<strong>3 Characteristics that wind power surge protectors must have<\/strong>\r\n\r\nThe motor side, transformer low voltage side and distribution cabinet network side of the wind power generation system must be Class I lightning protection, the continuous working voltage of the Type 1 power surge protector is greater than 690 Vac, which can reasonably protect the normal operation of wind power generation equipment.\r\n\r\nThe Class II power surge protector on the rotor side of the wind turbine is shock-proof and pluggable."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/blog\/838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/media\/839"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/media?parent=838"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/blog_category?post=838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}