{"id":903,"date":"2024-09-03T16:46:18","date_gmt":"2024-09-03T08:46:18","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=application&#038;p=903"},"modified":"2024-09-03T16:46:18","modified_gmt":"2024-09-03T08:46:18","slug":"protection-measures-of-inductive-lightning-in-spc-exchange","status":"publish","type":"application","link":"https:\/\/www.britecelectric.com\/hu\/solution\/protection-measures-of-inductive-lightning-in-spc-exchange\/","title":{"rendered":"Indukt\u00edv vill\u00e1mv\u00e9delmi int\u00e9zked\u00e9sek az SPC Exchange-ben"},"content":{"rendered":"<p>Az energiakommunik\u00e1ci\u00f3 a modern villamosenergia-rendszer n\u00e9lk\u00fcl\u00f6zhetetlen \u00e9s fontos r\u00e9sze, valamint a modern villamosenergia-h\u00e1l\u00f3zat biztons\u00e1gos \u00e9s stabil m\u0171k\u00f6d\u00e9s\u00e9nek h\u00e1rom pill\u00e9r\u00e9nek egyike. Az SPC Exchange az energiakommunik\u00e1ci\u00f3s h\u00e1l\u00f3zat fontos r\u00e9sze. Ha egyszer hiba t\u00f6rt\u00e9nik, az okozott vesztes\u00e9g nem csak gazdas\u00e1gos. M\u00e1sr\u00e9szt, ami komolyabb, az a h\u00e1l\u00f3zat biztons\u00e1g\u00e1t fenyeget\u0151 potenci\u00e1lis vesz\u00e9ly. Ez\u00e9rt k\u00fcl\u00f6n\u00f6sen fontos az SPC Exchange biztons\u00e1gi v\u00e9delm\u00e9nek meger\u0151s\u00edt\u00e9se.<\/p>\n<p>Most sok egys\u00e9g telep\u00edtette az SPC Exchange-et, \u00e9s az SPC Exchange f\u0151 \u00f6sszetev\u0151je az integr\u00e1lt \u00e1ramk\u00f6r (IC). Az IC interferencia-g\u00e1tl\u00f3 k\u00e9pess\u00e9ge viszonylag alacsony, \u00e9s m\u00e9g a vezet\u00e9kb\u0151l kiv\u00e1ltott vill\u00e1m elektrom\u00e1gneses impulzus (LEMP) is lebonthatja az IC alkatr\u00e9szeit. Ez\u00e9rt az SPC Exchange hajlamos a vill\u00e1mbalesetekre. A s\u00e9r\u00fclt r\u00e9szek t\u00f6bbnyire rel\u00e9 k\u00e1rty\u00e1k, felhaszn\u00e1l\u00f3i k\u00e1rty\u00e1k, sz\u00e1mlak\u00e1rty\u00e1k \u00e9s t\u00e1pegys\u00e9g alkatr\u00e9szek. Ezen alaplapok magas \u00e9rt\u00e9ke miatt, annak \u00e9rdek\u00e9ben, hogy cs\u00f6kkents\u00e9kgazdas\u00e1gi vesztes\u00e9geket, egyes felhaszn\u00e1l\u00f3k t\u00f6bbf\u00e9le m\u00f3dszert is kipr\u00f3b\u00e1ltak a kapcsol\u00f3 v\u00e9delm\u00e9re, s\u0151t biztos\u00edt\u00f3t\u00e1rsas\u00e1gn\u00e1l is biztos\u00edtott\u00e1k a kapcsol\u00f3t, de a vill\u00e1mcsap\u00e1s okozta kommunik\u00e1ci\u00f3s megszakad\u00e1sb\u00f3l ered\u0151 vesztes\u00e9g helyrehozhatatlan. Ez\u00e9rt az SPC Exchange vill\u00e1mv\u00e9delme k\u00fcl\u00f6n\u00f6sen fontos.<\/p>\n<p><strong>A kapcsol\u00f3 potenci\u00e1lkiegyenl\u00edt\u00e9se<\/strong><\/p>\n<p>A kapcsol\u00f3 potenci\u00e1lkiegyenl\u00edt\u00e9s\u00e9nek c\u00e9lja a k\u00fcl\u00f6nb\u00f6z\u0151 f\u00e9m alkatr\u00e9szek \u00e9s rendszerek k\u00f6z\u00f6tti potenci\u00e1lk\u00fcl\u00f6nbs\u00e9g cs\u00f6kkent\u00e9se abban a t\u00e9rben, ahol vill\u00e1mv\u00e9delem sz\u00fcks\u00e9ges.<\/p>\n<p><strong>Az \u00e9p\u00fclet vill\u00e1mv\u00e9delmi l\u00e9tes\u00edtm\u00e9nyeinek min\u0151s\u00e9ge<\/strong><\/p>\n<p>A GB50057-94 vonatkoz\u00f3 rendelkez\u00e9sei szerint az SPC Exchange \u00e9p\u00fclet\u00e9ben olyan eszk\u00f6z\u00f6kkel kell rendelkezni, amelyek megakad\u00e1lyozz\u00e1k a k\u00f6zvetlen vill\u00e1mcsap\u00e1st. Ha az \u00e9p\u00fclet magass\u00e1ga meghaladja a 30 m\u00e9tert (1-es t\u00edpus\u00fa vill\u00e1mv\u00e9delem), a 45 m-t (2-es t\u00edpus\u00fa vill\u00e1mv\u00e9delem) \u00e9s a 60 m-t (3-as t\u00edpus\u00fa vill\u00e1mv\u00e9delem), akkor a fenti magass\u00e1g\u00fa k\u00fcls\u0151 falon l\u00e9v\u0151 nagym\u00e9ret\u0171 f\u00e9mt\u00e1rgyakat, p\u00e9ld\u00e1ul korl\u00e1tokat, ajt\u00f3kat, ablakokat a vill\u00e1mv\u00e9delmi berendez\u00e9shez kell csatlakoztatni. Ezen k\u00edv\u00fcl a vill\u00e1ml\u00e1s f\u00f6ldel\u00e9si ellen\u00e1ll\u00e1saA v\u00e9delmi l\u00e9tes\u00edtm\u00e9nyeknek meg kell felelni\u00fck a vonatkoz\u00f3 el\u0151\u00edr\u00e1sok k\u00f6vetelm\u00e9nyeinek is.<\/p>\n<p><strong>Az \u00e9p\u00fcleten bel\u00fcli vill\u00e1mv\u00e9delmi z\u00f3na (LPZ).<\/strong><\/p>\n<p>Az IEC1312-1 vonatkoz\u00f3 rendelkez\u00e9sei szerint az \u00e9p\u00fclet 4 ter\u00fcletre van felosztva: LPZOA, az ezen a ter\u00fcleten l\u00e9v\u0151 objektumokba vill\u00e1mcsap\u00e1s k\u00f6zvetlen\u00fcl \u00fctk\u00f6zhet; LPZOB, ezen a ter\u00fcleten l\u00e9v\u0151 t\u00e1rgyakba nem \u00fctk\u00f6zhet k\u00f6zvetlen\u00fcl vill\u00e1m, \u00e9s a ter\u00fcleten az elektrom\u00e1gneses t\u00e9r nem csillapodik; LPZ1, ezen a ter\u00fcleten l\u00e9v\u0151 objektumokba nem \u00fctk\u00f6zhet k\u00f6zvetlen\u00fcl vill\u00e1m, \u00e9s a ter\u00fcleten l\u00e9v\u0151 elektrom\u00e1gneses t\u00e9r gyeng\u00fclhet; Az LPZ2 a k\u00f6vet\u0151 vill\u00e1mv\u00e9delmi ter\u00fclet. A fenti \u00f6vezeti elv szerint az SPCA cser\u00e9t a lehet\u0151 legnagyobb m\u00e9rt\u00e9kben az LPZ2 ter\u00fcleten kell elhelyezni, hogy cs\u00f6kkentse a vill\u00e1m elektrom\u00e1gneses impulzus\u00e1nak hat\u00e1s\u00e1t a kapcsol\u00f3ra.<\/p>\n<p><strong>Az SPC Exchange helyis\u00e9g helye<\/strong><\/p>\n<p>Az SPC Exchange helyis\u00e9g hely\u00e9t a terep elhelyezked\u00e9s\u00e9vel \u00e9s egy\u00e9b t\u00e9nyez\u0151kkel egy\u00fctt kell meghat\u00e1rozni. Sokemeletes \u00e9p\u00fcletekn\u00e9l az \u00e1ltal\u00e1nos gyakorlat az, hogy a helyis\u00e9get a 4. emelet alatti \u00e9s az els\u0151 emelet feletti t\u00e9rben helyezz\u00fck el. Nedves helyis\u00e9gekben nem c\u00e9lszer\u0171 a helyis\u00e9get az els\u0151 emeleten kialak\u00edtani.<\/p>\n<p>A modern kommunik\u00e1ci\u00f3s rendszerekben a j\u00f3l megtervezett vill\u00e1mv\u00e9delmi rendszer kritikus fontoss\u00e1g\u00fa a berendez\u00e9sek biztons\u00e1gos m\u0171k\u00f6d\u00e9se szempontj\u00e1b\u00f3l, nem csak az SPC Exchange eset\u00e9ben. A teljes kommunik\u00e1ci\u00f3s h\u00e1l\u00f3zat biztons\u00e1gos m\u0171k\u00f6d\u00e9se \u00e9rdek\u00e9ben szigor\u00faan be kell tartania az \u00e1tfog\u00f3 vill\u00e1mv\u00e9delem alapelveit, \u00e9s minden lehets\u00e9ges \u00fatvonalr\u00f3l meg kell tervezni a vill\u00e1mv\u00e9delmet.<\/p>","protected":false},"featured_media":849,"template":"","class_list":["post-903","application","type-application","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/application\/903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/types\/application"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/media\/849"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/hu\/wp-json\/wp\/v2\/media?parent=903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}