{"id":974,"date":"2024-09-04T11:52:46","date_gmt":"2024-09-04T03:52:46","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=974"},"modified":"2026-03-05T16:15:02","modified_gmt":"2026-03-05T08:15:02","slug":"br-25vg-1p-25ka-type-123-surge-protection-devices","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/fr\/product\/br-25vg-1p-25ka-type-123-surge-protection-devices\/","title":{"rendered":"Dispositifs de protection contre les surtensions BR-25VG 1P 25kA de type 1+2+3"},"content":{"rendered":"<h3>Description<\/h3><p><strong>Caract\u00e9ristiques du produit :<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Sp\u00e9cification<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 320 1P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 440 1P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 690 1P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Type 1 + Type 2 + Type 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Type 1 + Type 2 + Type 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Type 1 + Type 2 + Type 3<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II + Classe III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II + Classe III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe I + Classe II + Classe III<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tension de fonctionnement nominale<\/td>\n<td height=\"32\">ONU<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250V\/440V(50\/60Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250V\/440V(50\/60Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400V\/690V(50\/60Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant alternatif \u00e0 fonctionnement continu tension<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">690 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant de choc de foudre (10\/350\u03bcs)<\/td>\n<td height=\"32\">jeimp<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant de d\u00e9charge nominal (8\/20\u03bcs)<\/td>\n<td height=\"32\">Dans<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant de d\u00e9charge (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Quantit\u00e9 de charge \u00e9lectrique<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5Comme<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5Comme<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5Comme<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">\u00c9nergie sp\u00e9cifique<\/td>\n<td height=\"32\">W\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection contre la tension<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,8kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant nominal de court-circuit c.a.<\/td>\n<td height=\"32\">Iccr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA efficace<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA efficace<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA efficace<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. fusible de secours<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tenue temporaire aux surtensions TOV<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">580 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">800 V\/5 secondes.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">D\u00e9faillance temporaire de surtension TOV<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">765V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1000V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant de fuite<\/td>\n<td height=\"32\">Ip\u00e9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Aucun<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Aucun<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Aucun<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Temps de r\u00e9ponse<\/td>\n<td height=\"32\">ta<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Plage de temp\u00e9rature de fonctionnement<\/td>\n<td height=\"32\">Ma<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Indication d'\u00e9tat de fonctionnement\/de d\u00e9faut<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">vert\/rouge<\/td>\n<td style=\"text-align: center;\">vert\/rouge<\/td>\n<td style=\"text-align: center;\">vert\/rouge<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de la section transversale (Min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de section transversale (Max.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pour montage sur<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Rail Din 35 mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Mat\u00e9riau du bo\u00eetier<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Thermoplastique UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Degr\u00e9 de protection<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17267<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17279<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17291<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande (avec signalisation \u00e0 distance)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17268<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17280<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17292<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Caract\u00e9ristiques:<\/strong><\/p>\n<p>Le BR-25VG 1P est un dispositif parasurtenseur AC de type 1+2+3 con\u00e7u pour prot\u00e9ger l'entr\u00e9e de l'installation \u00e9lectrique.<\/p>\n<p>Composants puissants, adapt\u00e9s \u00e0 tous types de syst\u00e8mes \u00e9lectriques courants.<\/p>\n<p>Il y a un \u00e9l\u00e9ment de coupure thermique \u00e0 l'int\u00e9rieur du dispositif de protection, lorsque l'appareil est en surintensit\u00e9 ou en surtension, l'\u00e9l\u00e9ment de coupure thermique se s\u00e9parera automatiquement du dispositif de protection contre les surtensions du r\u00e9seau \u00e9lectrique et la fen\u00eatre d'indication passera du rouge au vert.<\/p>\n<p>L'unit\u00e9 est con\u00e7ue pour \u00eatre utilis\u00e9e entre la zone O et la zone 1 (selon la d\u00e9finition IEC62305-4 de la zone de protection contre la foudre).<\/p>\n<p>Ce parafoudre est particuli\u00e8rement utile dans une zone \u00e0 forte densit\u00e9 de foudre o\u00f9 le risque de surintensit\u00e9 importante voire de choc direct est \u00e9lev\u00e9 (ex : b\u00e2timents \u00e9quip\u00e9s de paratonnerres).<\/p>\n<p>Selon EN 61643-11 et CEI 61643-11<\/p>\n<p>Le BR-25VG 1P est un SPD unipolaire.<\/p>\n<p><strong>Application:<\/strong><\/p>\n<p>\u2022 Utilis\u00e9 dans la ligne \u00e9lectrique CA d'une maison, d'une banque, d'une tour de t\u00e9l\u00e9communication, etc.<\/p>\n<p>\u2022 Elle s'applique \u00e0 la protection contre la foudre du syst\u00e8me \u00e9lectrique dans les zones \u00e0 haut risque de foudre (LPZ0B ou interface entre LPZ0B et LPZ1).<\/p>\n<p>\u2022 Indiqu\u00e9 comme premi\u00e8re \u00e9tape de protection dans les panneaux d'alimentation \u00e9lectrique et dans les zones avec une plus grande exposition \u00e0 l'atmosph\u00e8re, o\u00f9 les installations sont g\u00e9n\u00e9ralement dot\u00e9es d'un syst\u00e8me externe de protection contre la foudre.<\/p>\n<p><strong>Installation:<\/strong><\/p>\n<p>\u2022 L'alimentation doit \u00eatre coup\u00e9e avant l'installation. L\u2019exploitation en direct est interdite.<\/p>\n<p>\u2022 Il est recommand\u00e9 de connecter un fusible ou un disjoncteur en s\u00e9rie \u00e0 l'extr\u00e9mit\u00e9 avant du dispositif de protection contre les surtensions.<\/p>\n<p>\u2022 Le SPD est install\u00e9 en parall\u00e8le \u00e0 l'extr\u00e9mit\u00e9 d'entr\u00e9e d'alimentation \u00e9lectrique du bo\u00eetier de distribution du b\u00e2timent ou du local technique. Le produit est install\u00e9 dans le type de rail de guidage. Si les conditions le permettent, le mode de connexion Kevin peut \u00eatre adopt\u00e9.<\/p>\n<p>\u2022 Lors de l'installation, connectez l'appareil conform\u00e9ment au sch\u00e9ma d'installation, o\u00f9 L est la ligne de phase, N est la ligne neutre et PE est la ligne de terre. Ne branchez pas mal l\u2019appareil. Une fois l'installation termin\u00e9e, allumez le disjoncteur automatique et v\u00e9rifiez si l'\u00e9tat de fonctionnement est normal.<\/p>\n<p>\u2022 Lorsque le SPD est utilis\u00e9, v\u00e9rifiez r\u00e9guli\u00e8rement l'\u00e9tat de la fen\u00eatre d'affichage des d\u00e9fauts. Si la fen\u00eatre d'affichage des d\u00e9fauts est rouge ou si le terminal distant \u00e9met un signal d'alarme, cela indique que le SPD est d\u00e9fectueux et doit \u00eatre r\u00e9par\u00e9 ou remplac\u00e9 \u00e0 temps.<\/p>\n<p>\u2022 Adapt\u00e9 \u00e0 un fonctionnement en int\u00e9rieur, tel qu'install\u00e9 \u00e0 l'ext\u00e9rieur, doit \u00eatre \u00e9quip\u00e9 d'une coque \u00e9tanche.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1629\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-1P-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":94,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-974","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product\/974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media?parent=974"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product_category?post=974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}