{"id":1174,"date":"2024-09-04T22:44:53","date_gmt":"2024-09-04T14:44:53","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=1174"},"modified":"2024-12-25T15:32:46","modified_gmt":"2024-12-25T07:32:46","slug":"br-110-11-type-2-110ka-surge-protective-device-for-tt-and-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/fr\/product\/br-110-11-type-2-110ka-surge-protective-device-for-tt-and-tns\/","title":{"rendered":"BR-110 1+1 Type 2 Dispositif de protection contre les surtensions 110 kA pour TT et TNS"},"content":{"rendered":"<h3>Description<\/h3><p><strong>Caract\u00e9ristiques du produit :<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Sp\u00e9cification<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 275 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 320 1+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-110 385 1+1<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant alternatif \u00e0 fonctionnement continu tension (L-N)<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">385V<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant alternatif \u00e0 fonctionnement continu tension (N-PE)<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">255V<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant de d\u00e9charge nominal (8\/20\u03bcs)<\/td>\n<td height=\"32\">Dans<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">50ka<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant de d\u00e9charge (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">110kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection de tension (L-N)<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,8kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection de tension 5kA (L-N)<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,0kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,1kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,2kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection de tension (N-PE)<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. fusible de secours<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Capacit\u00e9 de tenue aux courts-circuits<\/td>\n<td height=\"32\">Iccr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tenue temporaire aux surtensions TOV (L-N)<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">500 V\/5 secondes.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">D\u00e9faillance temporaire de surtension TOV (L-N)<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">650V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tenue temporaire aux surtensions TOV (N-PE)<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Temps de r\u00e9ponse (L-N)<\/td>\n<td height=\"32\">ta<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Temps de r\u00e9ponse (N-PE)<\/td>\n<td height=\"32\">ta<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Plage de temp\u00e9rature de fonctionnement<\/td>\n<td height=\"32\">Ma<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Indication d'\u00e9tat de fonctionnement\/de d\u00e9faut<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de la section transversale (Min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de section transversale (Max.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pour montage sur<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Rail Din 35 mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Mat\u00e9riau du bo\u00eetier<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Thermoplastique \u00a0UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Degr\u00e9 de protection<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18873<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18875<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18877<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande (avec signalisation \u00e0 distance)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18874<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18876<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18878<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Caract\u00e9ristiques:<\/strong><\/p>\n<p>1) Grande capacit\u00e9 de courant du d\u00e9chargeur, faible tension r\u00e9siduelle, r\u00e9ponse rapide<\/p>\n<p>2) IP20, UL94 V0<\/p>\n<p>3) Faible courant de fuite et taux de changement<\/p>\n<p>4) Dispositifs de protection contre les surtensions de classe II \/ Type 2.<\/p>\n<p>5) Technique d'isolation thermique, pas de catastrophe incendie<\/p>\n<p>6) Les pi\u00e8ces centrales sont des composants de varistance \u00e0 oxyde m\u00e9tallique avec une capacit\u00e9 de d\u00e9charge \u00e9lev\u00e9e.<\/p>\n<p>7) Appliquer des pi\u00e8ces de fusibles sp\u00e9ciales, avec une grande fiabilit\u00e9.<\/p>\n<p>8) Conformit\u00e9 aux normes\u00a0: IEC61643-11, EN61643-11<\/p>\n<p>9) Avec indicateur d'alimentation pour afficher l'\u00e9tat de fonctionnement<\/p>\n<p>10) Protection des appareils basse tension contre les surtensions pour les syst\u00e8mes d'alimentation TN-S (ou mode TT 1+1 en tant que sur mesure).<\/p>\n<p>11) Circuit de protection de contr\u00f4le de temp\u00e9rature, protection thermique int\u00e9gr\u00e9e, unit\u00e9 de d\u00e9clenchement automatique<\/p>\n<p>12) Montez sur le rail DIN de 35 mm.<\/p>\n<p>13) Mod\u00e8le de protection 1+1 (L-N, N-PE), adapt\u00e9 aux zones pauvres du r\u00e9seau \u00e9lectrique<\/p>\n<p>14) Courant de d\u00e9charge nominal\u00a0: 50 kA<\/p>\n<p>15) Max. Courant de d\u00e9charge\u00a0: 110 kA<\/p>\n<p>16) Processus exquis, peut fonctionner pendant une longue p\u00e9riode dans un environnement hostile, comme l'acide, l'alcali, la poussi\u00e8re, le brouillard salin, l'humidit\u00e9, etc.<\/p>\n<p><strong>Application:<\/strong><\/p>\n<p>1) L'alimentation triphas\u00e9e SPD convient \u00e0 la protection de l'alimentation du syst\u00e8me, telle qu'une salle de commutation, une armoire de distribution d'\u00e9nergie, une armoire de commande, un tableau de distribution CA, etc.<\/p>\n<p>2) \u00c0 utiliser dans le concept de zones de protection contre la foudre \u00e0 la limite 1-2.<\/p>\n<p>3) Bo\u00eete de distribution avec entr\u00e9e ext\u00e9rieure dans le b\u00e2timent et \u00e0 chaque \u00e9tage<\/p>\n<p>4) Ligne \u00e9lectrique CA de la maison, de la banque et de la tour de t\u00e9l\u00e9communication, etc.<\/p>\n<p>5) Le dispositif de protection contre les surtensions CA est utilis\u00e9 dans le syst\u00e8me d'alimentation CA (50\/60 Hz) et le syst\u00e8me de contr\u00f4le basse tension pour prot\u00e9ger contre la foudre et les surtensions transitoires.<\/p>\n<p>6) Salle des machines d'automatisation, panneau d'alimentation de la salle de contr\u00f4le principale de la station de conversion<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1655\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-11-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":154,"template":"","meta":{"_acf_changed":false},"product_category":[22],"class_list":["post-1174","product","type-product","status-publish","hentry","product_category-type-2-surge-protective-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product\/1174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media?parent=1174"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product_category?post=1174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}