{"id":1146,"date":"2024-09-04T22:28:42","date_gmt":"2024-09-04T14:28:42","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=1146"},"modified":"2024-12-24T15:05:12","modified_gmt":"2024-12-24T07:05:12","slug":"br-80-2p-type-2-80ka-surge-protective-device-for-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/fr\/product\/br-80-2p-type-2-80ka-surge-protective-device-for-tns\/","title":{"rendered":"Dispositif de protection contre les surtensions BR-80 2P Type 2 80kA pour TNS"},"content":{"rendered":"<h3>Description<\/h3><p><strong>Caract\u00e9ristiques du produit :<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Sp\u00e9cification<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-80 150 2P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-80 275 2P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-80 320 2P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-80 385 2P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tapez 2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Classification SPD selon IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Classe II<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant alternatif \u00e0 fonctionnement continu tension<\/td>\n<td height=\"32\">Uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320V<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">385V<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Courant de d\u00e9charge nominal (8\/20\u03bcs)<\/td>\n<td height=\"32\">Dans<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">40KA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">40KA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">40KA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">40KA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. courant de d\u00e9charge (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">80 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">80 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">80 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">80 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection contre la tension<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,0kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,7kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,0kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,3kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Niveau de protection de tension 5kA<\/td>\n<td height=\"32\">En haut<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22640,6kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,0kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,1kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,2kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. fusible de secours<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">160A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Capacit\u00e9 de tenue aux courts-circuits<\/td>\n<td height=\"32\">Iccr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tenue temporaire aux surtensions TOV<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">180 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400 V\/5 secondes.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">500 V\/5 secondes.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">D\u00e9faillance temporaire de surtension TOV<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">650V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Temps de r\u00e9ponse<\/td>\n<td height=\"32\">ta<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Plage de temp\u00e9rature de fonctionnement<\/td>\n<td height=\"32\">Ma<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40 \u2103-80 \u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Indication d'\u00e9tat de fonctionnement\/de d\u00e9faut<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">vert\/rouge<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de la section transversale (Min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Surface de section transversale (Max.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Pour montage sur<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Rail Din 35 mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Mat\u00e9riau du bo\u00eetier<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"5\" align=\"center\" valign=\"middle\" height=\"32\">Thermoplastique \u00a0UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Degr\u00e9 de protection<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ip20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18276<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18278<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18280<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18282<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Code de commande (avec signalisation \u00e0 distance)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18277<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18279<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18281<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18283<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Caract\u00e9ristiques:<\/strong><\/p>\n<p>Classe II, Type 2, 80 kA 2P.<\/p>\n<p>Courants de d\u00e9charge : In : 40 kA \/ Imax : 80 kA.<\/p>\n<p>Conformit\u00e9 CEI 61643-11 et EN 61643-11.<\/p>\n<p>Le BR-80 est compatible avec le rail DIN et est construit avec un module enfichable et une base fixe.<\/p>\n<p>Le BR-80 prot\u00e8ge contre les coups de foudre directs et indirects et les transitoires de commutation importants.<\/p>\n<p>Ils sont particuli\u00e8rement utiles dans les zones o\u00f9 l'espace est limit\u00e9.<\/p>\n<p>Une version avec signalisation \u00e0 distance pour indication de d\u00e9connexion est \u00e9galement disponible.<\/p>\n<p><strong>Application:<\/strong><\/p>\n<p>Largement appr\u00e9ci\u00e9s pour leur haut niveau de protection, leur efficacit\u00e9 et leurs performances fiables, ces parasurtenseurs monophas\u00e9s sont largement utilis\u00e9s pour prot\u00e9ger les appareils \u00e9lectriques tels que les ordinateurs, les t\u00e9l\u00e9viseurs et autres appareils.<\/p>\n<p>Application dans les installations industrielles, les b\u00e2timents commerciaux, les installations institutionnelles et les bureaux d'entreprise.<\/p>\n<p>\u00c0 utiliser dans le concept de zones de protection contre la foudre aux limites de LPZ 1-2 (selon CEI 1312-1 et EN62305).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1645\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-12.5M-2P-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":145,"template":"","meta":{"_acf_changed":false},"product_category":[22],"class_list":["post-1146","product","type-product","status-publish","hentry","product_category-type-2-surge-protective-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product\/1146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media?parent=1146"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/product_category?post=1146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}