{"id":879,"date":"2025-04-19T10:48:37","date_gmt":"2025-04-19T02:48:37","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=879"},"modified":"2025-04-19T11:23:19","modified_gmt":"2025-04-19T03:23:19","slug":"surge-protection-for-solar-photovoltaic-systems","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/fr\/blog\/surge-protection-for-solar-photovoltaic-systems\/","title":{"rendered":"Protection contre les surtensions pour les syst\u00e8mes solaires photovolta\u00efques"},"content":{"rendered":"<h2 data-start=\"52\" data-end=\"119\">Pourquoi les dispositifs de protection contre les surtensions sont essentiels pour les syst\u00e8mes solaires photovolta\u00efques<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">Les emplacements \u00e9loign\u00e9s, les vastes am\u00e9nagements et les surfaces expos\u00e9es des centrales solaires photovolta\u00efques (PV) les rendent tr\u00e8s vuln\u00e9rables aux risques environnementaux, en particulier aux orages \u00e9lectriques. L\u2019un des risques les plus importants concerne les dommages caus\u00e9s par la foudre directe ou indirecte, qui peuvent entra\u00eener des temps d\u2019arr\u00eat prolong\u00e9s du syst\u00e8me, une panne de l\u2019onduleur et d\u2019importantes pertes de revenus.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">Comment s\u00e9lectionner et installer les bons dispositifs de protection contre les surtensions photovolta\u00efques<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Les syst\u00e8mes photovolta\u00efques fonctionnent dans des conditions sp\u00e9cifiques qui n\u00e9cessitent des dispositifs de protection contre les surtensions photovolta\u00efques sp\u00e9cialement con\u00e7us pour les applications CC haute tension, souvent jusqu'\u00e0 1 500 V. Contrairement aux syst\u00e8mes AC, l\u2019environnement DC dans les panneaux solaires est continu et pr\u00e9sente des d\u00e9fis uniques.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">Pour choisir le SPD appropri\u00e9 pour votre syst\u00e8me solaire photovolta\u00efque, tenez compte des facteurs critiques suivants\u00a0:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">La densit\u00e9 des \u00e9clairs dans la zone d'installation<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">La plage de temp\u00e9rature de fonctionnement du syst\u00e8me<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">La tension nominale CC du syst\u00e8me (souvent jusqu'\u00e0 1 500\u00a0V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">Le courant de court-circuit (Isc) du g\u00e9n\u00e9rateur photovolta\u00efque<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">Le type d\u2019exposition aux surtensions (foudre transitoire, directe ou indirecte)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">Le courant de d\u00e9charge nominal requis (In) et la classe de protection (par exemple Type 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">Pour garantir une protection efficace, le niveau de protection en tension (Up) du SPD s\u00e9lectionn\u00e9 doit \u00eatre inf\u00e9rieur d'au moins 20% \u00e0 la rigidit\u00e9 di\u00e9lectrique de l'\u00e9quipement connect\u00e9, tel que l'onduleur ou le bo\u00eetier de combinaison.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">La mise en \u0153uvre d\u2019une bonne protection contre la foudre pour l\u2019\u00e9nergie solaire photovolta\u00efque n\u2019est pas seulement une mesure de s\u00e9curit\u00e9 : elle est essentielle pour maintenir la disponibilit\u00e9 du syst\u00e8me, prolonger la dur\u00e9e de vie des \u00e9quipements et prot\u00e9ger votre investissement dans les \u00e9nergies renouvelables.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/fr\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Dispositifs de protection contre les surtensions pour l&#039;\u00e9nergie solaire photovolta\u00efque\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>SPD lat\u00e9raux DC et AC pour bo\u00eetiers de combinaison et onduleurs<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes.","protected":false},"featured_media":880,"parent":0,"menu_order":138,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-879","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"The remote locations, exposed surface areas and extensive layouts of solar power plants put them at high risk of damage from the elements, particularly electrical storms.","txt":"<h2 data-start=\"52\" data-end=\"119\">Why Surge Protection Devices Are Essential for Solar PV Systems<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">The remote locations, expansive layouts, and exposed surfaces of solar photovoltaic (PV) power plants make them highly vulnerable to environmental hazards \u2014 especially electrical storms. One of the biggest risks is damage caused by direct or indirect lightning strikes, which can lead to extended system downtime, inverter failure, and major revenue losses.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">How to Select and Install the Right PV Surge Protection Devices<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Photovoltaic systems operate under specific conditions that require PV surge protection devices specifically engineered for high-voltage DC applications \u2014 often up to 1500V. Unlike AC systems, the DC environment in solar arrays is continuous and presents unique challenges.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">To choose the correct SPD for your solar PV system, consider the following critical factors:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">The lightning flash density in the installation area<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">The system\u2019s operating temperature range<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">The system\u2019s DC voltage rating (often up to 1500V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">The short-circuit current (Isc) of the PV array<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">The type of overvoltage exposure (transient, direct or indirect lightning)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">The required nominal discharge current (In) and protection class (e.g. Type 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">To ensure effective protection, the voltage protection level (Up) of the selected SPD must be at least 20% lower than the dielectric strength of the connected equipment, such as the inverter or combiner box.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">Implementing the right lightning protection for solar PV is not just a safety measure \u2014 it\u2019s essential for maintaining system uptime, extending equipment lifespan, and protecting your investment in renewable energy.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Surge Protection Devices For Solar PV\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>DC &amp; AC Side SPDs for combiner boxes and inverters<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog\/879","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media\/880"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media?parent=879"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog_category?post=879"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}