{"id":750,"date":"2023-12-19T20:39:19","date_gmt":"2023-12-19T12:39:19","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=750"},"modified":"2024-09-05T16:35:09","modified_gmt":"2024-09-05T08:35:09","slug":"how-surge-protection-devices-protect-photovoltaic-plants","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/fr\/blog\/how-surge-protection-devices-protect-photovoltaic-plants\/","title":{"rendered":"Comment les dispositifs de protection contre les surtensions prot\u00e8gent les installations photovolta\u00efques"},"content":{"rendered":"<strong>Dans les centrales photovolta\u00efques, les SPD doivent r\u00e9pondre \u00e0 des exigences sp\u00e9cifiques pour garantir un fonctionnement et une production d'\u00e9nergie continus.<\/strong>\r\n\r\nLors de la conception d'une installation photovolta\u00efque, il est important d'envisager l'installation de dispositifs de protection contre les surtensions (SPD). Les surtensions et les perturbations du r\u00e9seau peuvent entra\u00eener des temps d'arr\u00eat, r\u00e9duisant ainsi les performances de l'installation. Par cons\u00e9quent, toutes les conditions affectant la production et la distribution d\u2019\u00e9nergie doivent \u00eatre prises en compte lors de la conception de l\u2019installation \u00e9lectrique.\r\n\r\n<strong>Pourquoi les SPD sont-ils une priorit\u00e9 absolue dans les installations photovolta\u00efques\u00a0?<\/strong>\r\n\r\nSolar panels are installed outside to convert solar energy into electricity. This outdoor location makes them directly exposed to harsh conditions like rain, wind and dust. Among the weather conditions lightning strikes require specific attention as they can severely affect the safety and performance of a PV plant. They originate in a cumulonimbus cloud and terminate on the ground. When the lightning strike hits the ground, it discharges energy, affecting the electrical field on the ground. For the solar PV plant this poses two risks:\r\n\r\nA direct impact which can physically destroy the solar equipment on a rooftop\r\n\r\nTransitory over voltages passing through cables by magnetic coupling, which can lead to the damage of sensitive components such as printed circuit boards (PCB).\r\n\r\nAs far as the direct impact is concerned, \u2018External Lightning Protects\u2019 (ELP) provide the required protection according to IEC 62305, which describes how to evaluate if your location needs such protection, and what should be the preferred option (meshed cages, air terminal, etc.). The concept is simple: make sure the lightning will strike a metallic rod installed on the highest point of your plant and dispel the energy directly to the ground through a copper down conductor.\r\n\r\nWhen it comes to transitory over voltages, however, SPDs are required. They are installed in parallel into the circuit protection boards to divert the energy to the ground and limit the overvoltage up to such value acceptable to the end equipment.\r\n\r\nAs soon as ELP is installed at a PV plant, it is mandatory that an SPD be installed, too. If the PV plant is not equipped with an ELP, the installation of an SPD is highly recommended to limit network perturbations (transient over voltages).\r\n\r\n<strong>Comment fonctionne un SPD pour prot\u00e9ger le c\u00f4t\u00e9 DC des centrales solaires\u00a0?<\/strong>\r\n\r\nPour garantir que l'\u00e9nergie circulera d'abord vers la terre afin de limiter les surtensions, le composant le plus important est la varistance \u00e0 oxyde m\u00e9tallique (MOV, \u2018 Varistor \u2019 signifie VARI-able resi-STOR). Ce composant a une telle propri\u00e9t\u00e9 que dans des conditions normales (pas de surtensions) la r\u00e9sistance est suffisamment \u00e9lev\u00e9e pour ne pas laisser passer des courants nominaux. \u00c0 partir d'un certain niveau de surtension, la r\u00e9sistance chutera rapidement, ouvrant le chemin vers la terre et revenant \u00e0 un \u00e9tat normal une foisl'\u00e9nergie a \u00e9t\u00e9 dissip\u00e9e. Ce proc\u00e9d\u00e9 permet de limiter le niveau de surtension atteignant tous les \u00e9quipements connect\u00e9s en aval.\r\n\r\n<img class=\"alignnone size-full wp-image-752\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-2.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>\r\n\r\n<strong>SPD de type 1+2 par rapport au SPD de type 2 standard, lequel est le bon\u00a0?<\/strong>\r\n\r\nThere are different types of SPDs available which vary in terms of resistance: Type 1, Type 2, and Type 1+2. A Type 1 SPD can cope with a direct strike which bring an energetic surge, whereas a Type 2 limits over voltages from various sources. Both characteristics can be combined into a \u201cType 1+2\u201d for complete protection.\r\n\r\nIn PV plants the challenge is to choose the appropriate surge protection to withstand pure energy 10\/350\u00b5s waveform currents (almost 10 times more powerful than type 2 8\/20 \u00b5s waveform) while at the same time taking space into consideration. In an inverter or junction box space always is top priority. Britec\u2019s BRPV series provides both Type 1+2 and Type 2 DC surge protection can protect against over voltages due to lightning strikes or network surge current.\r\n\r\n<img class=\"alignnone wp-image-754\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-4.jpg\" alt=\"\" width=\"292\" height=\"292\" \/><img class=\"alignnone wp-image-753\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-3.jpg\" alt=\"\" width=\"293\" height=\"293\" \/><img class=\"alignnone size-full wp-image-755\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-5.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>","protected":false},"featured_media":779,"parent":0,"menu_order":184,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-750","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"At PV plants, SPDs have to fulfill specific requirements to ensure continuous operation and energy generation.","txt":"<strong>At PV plants, SPDs have to fulfill specific requirements to ensure continuous operation and energy generation.<\/strong>\r\n\r\nWhen designing a PV plant, it is important to consider the installation of surge protection devices (SPDs). Surges and network disturbances can lead to downtime, reducing the performance of the plant. Therefore, any conditions affecting energy generation and distribution should be taken into consideration when designing the electrical installation.\r\n\r\n<strong>Why are SPDs a top priority in PV plants?<\/strong>\r\n\r\nSolar panels are installed outside to convert solar energy into electricity. This outdoor location makes them directly exposed to harsh conditions like rain, wind and dust. Among the weather conditions lightning strikes require specific attention as they can severely affect the safety and performance of a PV plant. They originate in a cumulonimbus cloud and terminate on the ground. When the lightning strike hits the ground, it discharges energy, affecting the electrical field on the ground. For the solar PV plant this poses two risks:\r\n\r\nA direct impact which can physically destroy the solar equipment on a rooftop\r\n\r\nTransitory over voltages passing through cables by magnetic coupling, which can lead to the damage of sensitive components such as printed circuit boards (PCB).\r\n\r\nAs far as the direct impact is concerned, \u2018External Lightning Protects\u2019 (ELP) provide the required protection according to IEC 62305, which describes how to evaluate if your location needs such protection, and what should be the preferred option (meshed cages, air terminal, etc.). The concept is simple: make sure the lightning will strike a metallic rod installed on the highest point of your plant and dispel the energy directly to the ground through a copper down conductor.\r\n\r\nWhen it comes to transitory over voltages, however, SPDs are required. They are installed in parallel into the circuit protection boards to divert the energy to the ground and limit the overvoltage up to such value acceptable to the end equipment.\r\n\r\nAs soon as ELP is installed at a PV plant, it is mandatory that an SPD be installed, too. If the PV plant is not equipped with an ELP, the installation of an SPD is highly recommended to limit network perturbations (transient over voltages).\r\n\r\n<strong>How does an SPD work to protect the DC side of solar plants?<\/strong>\r\n\r\nTo guarantee the energy will flow to the ground first to limit over voltages the most important component is the Metal Oxide Varistor (MOV, \u2018Varistor\u2019 stands for VARI-able resi-STOR). This component has such propriety that in normal conditions (no over voltages) the resistance is high enough to not make possible nominal currents passing through it. Starting at a certain overvoltage level, the resistance will quickly drop, opening the path to the ground and coming back to a normal condition once the energy has been dissipated. This process allows limitation of the overvoltage level reaching all equipment connected downstream.\r\n\r\n<img class=\"alignnone size-full wp-image-752\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-2.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>\r\n\r\n<strong>Type1+2 SPD versus standard Type 2 SPD, which one is the right one?<\/strong>\r\n\r\nThere are different types of SPDs available which vary in terms of resistance: Type 1, Type 2, and Type 1+2. A Type 1 SPD can cope with a direct strike which bring an energetic surge, whereas a Type 2 limits over voltages from various sources. Both characteristics can be combined into a \u201cType 1+2\u201d for complete protection.\r\n\r\nIn PV plants the challenge is to choose the appropriate surge protection to withstand pure energy 10\/350\u00b5s waveform currents (almost 10 times more powerful than type 2 8\/20 \u00b5s waveform) while at the same time taking space into consideration. In an inverter or junction box space always is top priority. Britec\u2019s BRPV series provides both Type 1+2 and Type 2 DC surge protection can protect against over voltages due to lightning strikes or network surge current.\r\n\r\n<img class=\"alignnone wp-image-754\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-4.jpg\" alt=\"\" width=\"292\" height=\"292\" \/><img class=\"alignnone wp-image-753\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-3.jpg\" alt=\"\" width=\"293\" height=\"293\" \/><img class=\"alignnone size-full wp-image-755\" src=\"http:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/How-Surge-Protection-Devices-protect-photovoltaic-plants-5.jpg\" alt=\"\" width=\"300\" height=\"300\" \/>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog\/750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media\/779"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/media?parent=750"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fr\/wp-json\/wp\/v2\/blog_category?post=750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}