{"id":838,"date":"2023-12-18T15:02:31","date_gmt":"2023-12-18T07:02:31","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=838"},"modified":"2024-09-05T16:32:20","modified_gmt":"2024-09-05T08:32:20","slug":"wind-power-generation-lightning-protection-solutions","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/fi\/blog\/wind-power-generation-lightning-protection-solutions\/","title":{"rendered":"Tuulivoiman ukkossuojaratkaisut"},"content":{"rendered":"Tuulivoiman tuotantolaitteet sijaitsevat pitk\u00e4\u00e4n laajalla ulkoalueella ja salamaniskujen todenn\u00e4k\u00f6isyys on eritt\u00e4in korkea. Tuulilaiteinvestoinnit ovat suuria, aina salaman iskeess\u00e4 laitteiden yll\u00e4pito on kallista. Tuulivoimantuotannossa ylij\u00e4nnitesuojan palotaajuus on vain toiseksi suurnopeusjuna- ja viestint\u00e4teollisuudessa. Siksi ukkossuojaus on tuulivoiman t\u00e4rkein prioriteetti.\r\n\r\n<strong>1 Asiaankuuluva tuulivoimantuotannon ukkossuojausm\u00e4\u00e4r\u00e4ys<\/strong>\r\n\r\nTuulivoimalaitteissa k\u00e4ytettyjen ylij\u00e4nnitesuojainten on t\u00e4ytett\u00e4v\u00e4 kaikki seuraavat vaatimukset:\r\n<ul>\r\n \t<li>IEC 62305<\/li>\r\n \t<li>IEC 61312<\/li>\r\n \t<li>IEC 61400-24<\/li>\r\n \t<li>IEC 61643-11<\/li>\r\n<\/ul>\r\n<strong>2 Tuulivoiman ylij\u00e4nnitesuojaimia valittaessa on otettava huomioon 5 n\u00e4k\u00f6kohta<\/strong>\r\n<ul>\r\n \t<li>Ukkossuojausalue (LPZ 0\u20263)<\/li>\r\n \t<li>SPD noudattaa testivirran aaltomuotoa (8\/20 aalto ja 10\/350 aalto jne.)<\/li>\r\n \t<li>J\u00e4nnitteen suojaustaso (yl\u00f6s)<\/li>\r\n \t<li>Virtal\u00e4hdej\u00e4rjestelm\u00e4n j\u00e4nnite ja standardi (230\/400V ja 400\/690V j\u00e4rjestelm\u00e4t)<\/li>\r\n<\/ul>\r\n<strong>3 Ominaisuudet, jotka tuulivoiman ylij\u00e4nnitesuojalla on oltava<\/strong>\r\n\r\nThe motor side, transformer low voltage side and distribution cabinet network side of the wind power generation system must be Class I lightning protection, the continuous working voltage of the Type 1 power surge protector is greater than 690 Vac, which can reasonably protect the normal operation of wind power generation equipment.\r\n\r\nThe Class II power surge protector on the rotor side of the wind turbine is shock-proof and pluggable.","protected":false},"featured_media":839,"parent":0,"menu_order":158,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-838","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Wind power generation equipment is located in a wide outdoor area for a long time, and the probability of lightning strikes is very high.","txt":"Wind power generation equipment is located in a wide outdoor area for a long time, and the probability of lightning strikes is very high. Wind equipment investment is large, each time lightning strikes, the maintenance of the equipment is expensive. In wind power generation, the fire frequency of surge protector is only second to that of high-speed rail and communication industry. Therefore, lightning protection is a top priority for wind power.\r\n\r\n<strong>1 Relevant regulation for lightning protection of wind power generation<\/strong>\r\n\r\nSurge protectors used in wind power generation equipment must comply with all of the following specifications:\r\n<ul>\r\n \t<li>IEC 62305<\/li>\r\n \t<li>IEC 61312<\/li>\r\n \t<li>IEC 61400-24<\/li>\r\n \t<li>IEC 61643-11<\/li>\r\n<\/ul>\r\n<strong>2 The selection of wind power surge protectors needs to take into account the 5 aspect<\/strong>\r\n<ul>\r\n \t<li>Lightning protection area (LPZ 0\u2026 3)<\/li>\r\n \t<li>SPD conforms to the test current waveform (8\/20 wave and 10\/350 wave, etc.)<\/li>\r\n \t<li>Voltage protection level (Up)<\/li>\r\n \t<li>Power supply system voltage and standard (230\/400V and 400\/690 V systems)<\/li>\r\n<\/ul>\r\n<strong>3 Characteristics that wind power surge protectors must have<\/strong>\r\n\r\nThe motor side, transformer low voltage side and distribution cabinet network side of the wind power generation system must be Class I lightning protection, the continuous working voltage of the Type 1 power surge protector is greater than 690 Vac, which can reasonably protect the normal operation of wind power generation equipment.\r\n\r\nThe Class II power surge protector on the rotor side of the wind turbine is shock-proof and pluggable."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog\/838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/media\/839"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/media?parent=838"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog_category?post=838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}