{"id":2285,"date":"2025-12-19T09:12:07","date_gmt":"2025-12-19T01:12:07","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2285"},"modified":"2025-12-18T13:34:54","modified_gmt":"2025-12-18T05:34:54","slug":"6-differences-25ka-vs-50ka-vs-80ka-surge-protector","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/fi\/blog\/6-differences-25ka-vs-50ka-vs-80ka-surge-protector\/","title":{"rendered":"6 eroa: 25KA VS 50KA VS 80KA ylij\u00e4nnitesuoja"},"content":{"rendered":"When selecting a surge protector, the maximum discharge current (Imax), commonly known as the \"KA value,\" is a key indicator. It represents the maximum surge current the SPD can discharge in a single operation. A higher value indicates stronger resistance to extreme surges.\r\n\r\nThis article will provide an in-depth comparison of three common specifications: 25KA, 50KA, and 80KA <a href=\"https:\/\/www.britecelectric.com\/fi\/product-category\/ac-power-surge-protection\/type-2-surge-protective-device\/\">ylij\u00e4nnitesuoja<\/a>, jotta voit tehd\u00e4 tietoisen valinnan.\r\n<h2>25KA VS 50KA VS 80KA ylij\u00e4nnitesuoja<\/h2>\r\n<h3>Ydinosaaminen<\/h3>\r\n25KA SPD: Perussuojaustyyppi. Suurin purkausvirta 25 kA per moduuli (8\/20 \u03bcs aaltomuoto). Soveltuu keskitehoisten salamavirtojen tai indusoitujen ylij\u00e4nnitteiden jakamiseen.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/fi\/product\/br-50gr-4p-type-1-50ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1583\"><img class=\"alignnone size-full wp-image-1583\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-50GR-4P.jpg\" alt=\"BR-50GR 4P Tyypin 1 50 kA ylij\u00e4nnitesuoja TNS:lle\" width=\"800\" \/><\/a>\r\n\r\n50KA Surge Protector: Main protection type. Maximum discharge current of 50kA per module. Significantly improved protection capability, effectively resisting powerful induced surges caused by direct lightning strikes or nearby lightning strikes.\r\n\r\n80KA SPD: High-strength protection type. Maximum discharge current of 80kA per module. Possesses the strongest single-impulse withstand capability, suitable for high-risk or critical facilities.\r\n<h3>Sovellettavat skenaariot<\/h3>\r\n25KA: Suitable for low thunderstorm risk areas, secondary or tertiary distribution boxes inside buildings, residential distribution boxes, and fine protection for individual critical equipment (such as air conditioners and computers).\r\n\r\n50KA: Suitable for medium to high thunderstorm risk areas, main distribution boxes (primary protection) in urban residential and small-to-medium-sized commercial buildings, small computer rooms, and main lines for monitoring systems.\r\n\r\n80KA: Suitable for high thunderstorm risk areas, detached buildings in rural\/mountainous areas, main incoming lines for villas, factory workshops, communication base stations, solar photovoltaic systems, and main power distribution systems in critical locations such as hospitals and data centers.\r\n<h3>Asennuspaikka<\/h3>\r\n25KA: Typically installed in distribution boxes (secondary SPD) or at the front end of equipment (tertiary SPD), coordinating with upstream SPDs to achieve energy balance.\r\n\r\n50KA: Commonly found in main distribution cabinets (primary SPD) of small and medium-sized buildings, serving as the first line of defense.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/fi\/product\/br-80-4p-type-2-80ka-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1682\"><img class=\"alignnone size-full wp-image-1682\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-80-4P-1.jpg\" alt=\"BR-80 4P Type 2 80kA ylij\u00e4nnitesuoja TNS:lle\" width=\"800\" \/><\/a>\r\n\r\n80KA Surge Protector: K\u00e4ytet\u00e4\u00e4n enimm\u00e4kseen suurten rakennusten p\u00e4\u00e4sis\u00e4\u00e4ntulokaapeissa ja itsen\u00e4isten rakennusten mittarikoteloissa (ensisijainen SPD) kest\u00e4m\u00e4\u00e4n vakavimmat ylij\u00e4nniteiskut.\r\n<h3>Hinta ja m\u00e4\u00e4r\u00e4<\/h3>\r\nPrice: 25KA &lt; 50KA &lt; 80KA. The price increases with improved protection capability, but the relationship is not linear. The 80KA module has a larger unit price due to higher material and manufacturing requirements.\r\n\r\nSize: The 80KA module is typically the largest due to its larger internal varistor chip and gaps, resulting in higher requirements for heat dissipation and arc suppression. Space within the distribution box must be considered during installation.\r\n<h3>Edut<\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/fi\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone size-full wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P tyypin 1 25 kA salama ylij\u00e4nnitesuojalaite\" width=\"800\" \/><\/a>\r\n\r\n25KA Surge Protector: Low cost, small size, easy to install and replace, meeting the basic protection needs of most indoor scenarios.\r\n\r\n50KA: High cost-effectiveness, achieving a good balance between protection strength and cost, making it a \"sweet spot\" choice for Level 1 protection in civil and general commercial buildings.\r\n\r\n80KA: Strongest protection capability, large single-discharge margin, providing a higher safety margin for critical facilities, and higher equipment survival rate in extreme situations.\r\n<h3>Haitat<\/h3>\r\n25KA: Limited discharge capacity; may fail or be damaged prematurely due to overload under strong surge impact.\r\n\r\n50KA: For very large buildings or extremely high-risk environments, higher-capacity SPDs or more sophisticated multi-stage configurations may still be required.\r\n\r\n80KA: High initial investment; may result in waste due to over-protection; large size, requiring ample installation space.\r\n<h2>Kuinka valita? T\u00e4ss\u00e4 on vaiheittainen opas<\/h2>\r\n<h3>Arvioi ulkoiset ymp\u00e4rist\u00f6riskit<\/h3>\r\nCheck the annual average number of thunderstorm days: Less than 25 days indicates a low-thunderstorm area, 25-40 days a moderate-thunderstorm area, and more than 40 days a high-thunderstorm\/severe-thunderstorm area.\r\n\r\nConsider the building environment: Is the building isolated, located on high ground, near water, or in an open area? Are there taller buildings nearby providing shielding? These factors significantly affect the risk of lightning strikes.\r\n<h3>Selvenn\u00e4 sis\u00e4iset suojausvaatimukset<\/h3>\r\nValue of the protected object: Is the protection for ordinary household appliances, home theaters, high-end computers, smart home systems, or enterprise servers and precision instruments?\r\n\r\nSystem tolerance: How well does the protected equipment withstand overvoltage? The more sophisticated the equipment, the stronger the surge suppression required from the upstream stage.\r\n<h3>Perhek\u00e4ytt\u00e4j\u00e4t tekev\u00e4t valintasi<\/h3>\r\n<h4>Urban Standard -huoneistot<\/h4>\r\nRecommendation: Use a 25kA voltage regulator as secondary supplementary protection for the indoor distribution box.\r\n\r\nReason: The building itself already has primary lightning protection, reducing the risk of entry into the unit. 25kA is sufficient to handle indoor switch operations and residual surges, protecting indoor electrical appliances.\r\n\r\n&nbsp;\r\n<h4>\u00a0Huvilat \/ esikaupunkien itse rakennetut talot<\/h4>\r\nHighly recommended: Install 50KA or 80KA as primary protection at the meter box or main switch.\r\n\r\nReason: The building is isolated and directly exposed to the environment. In areas with moderate to severe lightning strikes, especially in suburban areas with poor power grid quality, 80KA provides greater peace of mind.\r\n<h4>Vanhat asuinalueet\/v\u00e4liaikainen suojelu<\/h4>\r\nSolution: If the main incoming line cannot be modified, a dedicated 25KA protective socket or module can be connected in series before the sockets of important appliances (such as refrigerators and televisions).\r\n\r\nNote: This is a \"last line of defense\" and is not as effective as system-level protection.\r\n<h3>T\u00e4rke\u00e4 huomautus<\/h3>\r\nMulti-level coordination: Optimal protection involves tiered discharge. For example: 80kA for the main incoming line (Level 1), 50kA for floor distribution boxes (Level 2), and 25kA for indoor boxes or equipment (Level 3).\r\n\r\nGrounding is crucial: No matter how good the SPD, a good grounding system (grounding resistance \u226410\u03a9, ideally \u22644\u03a9) is essential for effective current discharge.\r\n\r\nPay attention to additional parameters: In addition to the kA value, consider the protection voltage level (Up), which represents the residual voltage. The lower the value, the better the equipment protection.\r\n<h2>FAQ<\/h2>\r\n<strong>Ylij\u00e4nnitesuojat vs ilmakytkimet Suojat<\/strong>\r\n\r\nIlmakatkaisijat suojaavat ylikuormitukselta ja oikosuluilta, kun taas ylij\u00e4nnitesuojat suojaavat erityisesti ohimenevilt\u00e4 ylij\u00e4nnitteilt\u00e4.\r\n\r\n<strong>Ylij\u00e4nnitesuojat vs. j\u00e4\u00e4nn\u00f6svirtalaitteet<\/strong>\r\n\r\nNe ovat t\u00e4ysin erilaisia. Katkaisijat suojaavat ylikuormituksilta ja oikosuluilta; j\u00e4\u00e4nn\u00f6svirtalaitteet (RCD) suojaavat s\u00e4hk\u00f6iskulta; ylij\u00e4nnitesuojat on erityisesti suunniteltu suojaamaan ohimenevilt\u00e4 ylij\u00e4nnitteilt\u00e4. Ne t\u00e4ydent\u00e4v\u00e4t toisiaan ja niit\u00e4 tulee k\u00e4ytt\u00e4\u00e4 yhdess\u00e4.\r\n\r\n<strong>Tarvitsenko huoltoa asennuksen j\u00e4lkeen?<\/strong>\r\n\r\nKyll\u00e4. Useimmissa SPD:iss\u00e4 on vikailmaisinikkuna (muuttuu punaiseksi). On suositeltavaa tarkistaa ennen ja j\u00e4lkeen sadekauden ja vaihtaa ne v\u00e4litt\u00f6m\u00e4sti, jos ne ep\u00e4onnistuvat. Modulaariset SPD:t ovat hot-swap-vaihtokelpoisia.\r\n\r\n<strong>Is A Larger KA Value Better? Will It Be 'Surplus'?<\/strong>\r\n\r\nLarger is not always better. A KA value exceeding actual needs means unnecessary expense and space occupation. Furthermore, the startup voltage\/response characteristics of a high-KA SPD may not be well-matched with downstream equipment. The principle of \"appropriate protection and tiered coordination\" should be followed.\r\n\r\n<strong>Mik\u00e4 on Surge? Mik\u00e4 on KA-arvo?<\/strong>\r\n\r\nA surge is a brief voltage\/current spike in a circuit. KA (kiloampere) is the \"flood discharge capacity\" indicator of an SPD, representing the maximum peak current it can safely discharge.\r\n\r\n<strong>Kuinka ylij\u00e4nnitesuoja (SPD) toimii?<\/strong>\r\nSen ydinkomponentit (kuten varistorit) osoittavat suurta resistanssia normaalilla j\u00e4nnitteell\u00e4, mik\u00e4 vastaa avointa piiri\u00e4; Kun ylij\u00e4nnitesuoja havaitaan, siit\u00e4 tulee v\u00e4litt\u00f6m\u00e4sti eritt\u00e4in pieni vastus ohittaen virran maadoitusjohtimeen. Kun j\u00e4nnite palaa normaaliksi, se palaa korkean resistanssin tilaan.\r\n<h2>Johtop\u00e4\u00e4t\u00f6s<\/h2>\r\nChoosing between 25KA, 50KA, and 80KA surge protectors essentially involves finding a balance between protection strength, cost budget, and actual risk.\r\n\r\nFor basic, economical protection, choose 25KA.\r\n\r\nFor reliable protection with broad applicability, 50KA is the preferred choice.\r\n\r\nFor high-risk environments and protecting critical assets, 80KA is a worthwhile investment.\r\n\r\nThe most scientific approach is to conduct a risk assessment and consider multi-level coordination. Investing in a suitable surge protection solution for your home or business's electrical system is like providing reliable \"insurance\" for all electronic devices; the peace of mind it offers far outweighs its cost.","protected":false},"featured_media":2286,"parent":0,"menu_order":86,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2285","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"This article will provide an in-depth comparison of three common specifications: 25KA, 50KA, and 80KA surge protector, to help you make an informed choice.","txt":"When selecting a surge protector, the maximum discharge current (Imax), commonly known as the \"KA value,\" is a key indicator. It represents the maximum surge current the SPD can discharge in a single operation. A higher value indicates stronger resistance to extreme surges.\r\n\r\nThis article will provide an in-depth comparison of three common specifications: 25KA, 50KA, and 80KA <a href=\"https:\/\/www.britecelectric.com\/product-category\/ac-power-surge-protection\/type-2-surge-protective-device\/\">surge protector<\/a>, to help you make an informed choice.\r\n<h2>25KA VS 50KA VS 80KA Surge Protector<\/h2>\r\n<h3>Core Competence<\/h3>\r\n25KA SPD: Basic protection type. Maximum discharge current of 25kA per module (8\/20\u03bcs waveform). Suitable for sharing medium-intensity lightning currents or induced overvoltages.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-50gr-4p-type-1-50ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1583\"><img class=\"alignnone size-full wp-image-1583\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-50GR-4P.jpg\" alt=\"BR-50GR 4P Type 1 50kA Surge Arrester for TNS\" width=\"800\" \/><\/a>\r\n\r\n50KA Surge Protector: Main protection type. Maximum discharge current of 50kA per module. Significantly improved protection capability, effectively resisting powerful induced surges caused by direct lightning strikes or nearby lightning strikes.\r\n\r\n80KA SPD: High-strength protection type. Maximum discharge current of 80kA per module. Possesses the strongest single-impulse withstand capability, suitable for high-risk or critical facilities.\r\n<h3>Applicable Scenarios<\/h3>\r\n25KA: Suitable for low thunderstorm risk areas, secondary or tertiary distribution boxes inside buildings, residential distribution boxes, and fine protection for individual critical equipment (such as air conditioners and computers).\r\n\r\n50KA: Suitable for medium to high thunderstorm risk areas, main distribution boxes (primary protection) in urban residential and small-to-medium-sized commercial buildings, small computer rooms, and main lines for monitoring systems.\r\n\r\n80KA: Suitable for high thunderstorm risk areas, detached buildings in rural\/mountainous areas, main incoming lines for villas, factory workshops, communication base stations, solar photovoltaic systems, and main power distribution systems in critical locations such as hospitals and data centers.\r\n<h3>Installation Location<\/h3>\r\n25KA: Typically installed in distribution boxes (secondary SPD) or at the front end of equipment (tertiary SPD), coordinating with upstream SPDs to achieve energy balance.\r\n\r\n50KA: Commonly found in main distribution cabinets (primary SPD) of small and medium-sized buildings, serving as the first line of defense.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-80-4p-type-2-80ka-surge-protective-device-for-tns\/\" rel=\"attachment wp-att-1682\"><img class=\"alignnone size-full wp-image-1682\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-80-4P-1.jpg\" alt=\"BR-80 4P Type 2 80kA Surge Protective Device For TNS\" width=\"800\" \/><\/a>\r\n\r\n80KA Surge Protector: Mostly used in main incoming line cabinets of large buildings and meter boxes in independent buildings (primary SPD), to withstand the most severe surge impacts.\r\n<h3>Price And Volume<\/h3>\r\nPrice: 25KA &lt; 50KA &lt; 80KA. The price increases with improved protection capability, but the relationship is not linear. The 80KA module has a larger unit price due to higher material and manufacturing requirements.\r\n\r\nSize: The 80KA module is typically the largest due to its larger internal varistor chip and gaps, resulting in higher requirements for heat dissipation and arc suppression. Space within the distribution box must be considered during installation.\r\n<h3>Advantages<\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-4p-type-1-25ka-surge-arrester-for-tns\/\" rel=\"attachment wp-att-1601\"><img class=\"alignnone size-full wp-image-1601\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/08\/BR-25M-4P.jpg\" alt=\"BR-25M 4P Type 1 25kA Lightning Surge Protection Device\" width=\"800\" \/><\/a>\r\n\r\n25KA Surge Protector: Low cost, small size, easy to install and replace, meeting the basic protection needs of most indoor scenarios.\r\n\r\n50KA: High cost-effectiveness, achieving a good balance between protection strength and cost, making it a \"sweet spot\" choice for Level 1 protection in civil and general commercial buildings.\r\n\r\n80KA: Strongest protection capability, large single-discharge margin, providing a higher safety margin for critical facilities, and higher equipment survival rate in extreme situations.\r\n<h3>Disadvantages<\/h3>\r\n25KA: Limited discharge capacity; may fail or be damaged prematurely due to overload under strong surge impact.\r\n\r\n50KA: For very large buildings or extremely high-risk environments, higher-capacity SPDs or more sophisticated multi-stage configurations may still be required.\r\n\r\n80KA: High initial investment; may result in waste due to over-protection; large size, requiring ample installation space.\r\n<h2>How To Choose? Here Is Your Step-By-Step Guide<\/h2>\r\n<h3>Evaluate External Environmental Risks<\/h3>\r\nCheck the annual average number of thunderstorm days: Less than 25 days indicates a low-thunderstorm area, 25-40 days a moderate-thunderstorm area, and more than 40 days a high-thunderstorm\/severe-thunderstorm area.\r\n\r\nConsider the building environment: Is the building isolated, located on high ground, near water, or in an open area? Are there taller buildings nearby providing shielding? These factors significantly affect the risk of lightning strikes.\r\n<h3>Clarify Internal Protection Requirements<\/h3>\r\nValue of the protected object: Is the protection for ordinary household appliances, home theaters, high-end computers, smart home systems, or enterprise servers and precision instruments?\r\n\r\nSystem tolerance: How well does the protected equipment withstand overvoltage? The more sophisticated the equipment, the stronger the surge suppression required from the upstream stage.\r\n<h3>Family Users Make Your Choices<\/h3>\r\n<h4>Urban Standard Apartments<\/h4>\r\nRecommendation: Use a 25kA voltage regulator as secondary supplementary protection for the indoor distribution box.\r\n\r\nReason: The building itself already has primary lightning protection, reducing the risk of entry into the unit. 25kA is sufficient to handle indoor switch operations and residual surges, protecting indoor electrical appliances.\r\n\r\n&nbsp;\r\n<h4>\u00a0Villas\/Suburban Self Built Houses<\/h4>\r\nHighly recommended: Install 50KA or 80KA as primary protection at the meter box or main switch.\r\n\r\nReason: The building is isolated and directly exposed to the environment. In areas with moderate to severe lightning strikes, especially in suburban areas with poor power grid quality, 80KA provides greater peace of mind.\r\n<h4>Old Residential Areas\/Temporary Protection<\/h4>\r\nSolution: If the main incoming line cannot be modified, a dedicated 25KA protective socket or module can be connected in series before the sockets of important appliances (such as refrigerators and televisions).\r\n\r\nNote: This is a \"last line of defense\" and is not as effective as system-level protection.\r\n<h3>Important Notice<\/h3>\r\nMulti-level coordination: Optimal protection involves tiered discharge. For example: 80kA for the main incoming line (Level 1), 50kA for floor distribution boxes (Level 2), and 25kA for indoor boxes or equipment (Level 3).\r\n\r\nGrounding is crucial: No matter how good the SPD, a good grounding system (grounding resistance \u226410\u03a9, ideally \u22644\u03a9) is essential for effective current discharge.\r\n\r\nPay attention to additional parameters: In addition to the kA value, consider the protection voltage level (Up), which represents the residual voltage. The lower the value, the better the equipment protection.\r\n<h2>FAQ<\/h2>\r\n<strong>Surge Protectors Vs Air Switches Protectors<\/strong>\r\n\r\nAir circuit breakers protect against overload and short circuits, while surge protectors specifically protect against transient overvoltages.\r\n\r\n<strong>Surge Protectors Vs Residual Current Devices<\/strong>\r\n\r\nThey are completely different. Circuit breakers protect against overloads and short circuits; residual current devices (RCDs) protect against electric shock; surge protectors are specifically designed to protect against transient overvoltages. They are complementary in function and must be used in combination.\r\n\r\n<strong>Do I Need Maintenance After Installation?<\/strong>\r\n\r\nYes. Most SPDs have a failure indicator window (turns red). It is recommended to check before and after the rainy season, and replace them promptly if they fail. Modular SPDs are hot-swappable.\r\n\r\n<strong>Is A Larger KA Value Better? Will It Be 'Surplus'?<\/strong>\r\n\r\nLarger is not always better. A KA value exceeding actual needs means unnecessary expense and space occupation. Furthermore, the startup voltage\/response characteristics of a high-KA SPD may not be well-matched with downstream equipment. The principle of \"appropriate protection and tiered coordination\" should be followed.\r\n\r\n<strong>What Is A Surge? What Is KA Value?<\/strong>\r\n\r\nA surge is a brief voltage\/current spike in a circuit. KA (kiloampere) is the \"flood discharge capacity\" indicator of an SPD, representing the maximum peak current it can safely discharge.\r\n\r\n<strong>How Does A Surge Protector (SPD) Work?<\/strong>\r\nIts core components (such as varistors) exhibit high resistance under normal voltage, which is equivalent to an open circuit; once a surge high voltage is detected, it instantly becomes extremely low resistance, bypassing the current to the ground wire. After the voltage returns to normal, it returns to the high resistance state.\r\n<h2>Conclusion<\/h2>\r\nChoosing between 25KA, 50KA, and 80KA surge protectors essentially involves finding a balance between protection strength, cost budget, and actual risk.\r\n\r\nFor basic, economical protection, choose 25KA.\r\n\r\nFor reliable protection with broad applicability, 50KA is the preferred choice.\r\n\r\nFor high-risk environments and protecting critical assets, 80KA is a worthwhile investment.\r\n\r\nThe most scientific approach is to conduct a risk assessment and consider multi-level coordination. Investing in a suitable surge protection solution for your home or business's electrical system is like providing reliable \"insurance\" for all electronic devices; the peace of mind it offers far outweighs its cost."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog\/2285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/media\/2286"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/media?parent=2285"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/fi\/wp-json\/wp\/v2\/blog_category?post=2285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}