{"id":965,"date":"2024-09-04T11:29:41","date_gmt":"2024-09-04T03:29:41","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=965"},"modified":"2026-03-05T16:12:19","modified_gmt":"2026-03-05T08:12:19","slug":"br-25vg-4p-25ka-t1-surge-protector","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/es\/product\/br-25vg-4p-25ka-t1-surge-protector\/","title":{"rendered":"Protector contra sobretensiones BR-25VG 4P 25kA T1"},"content":{"rendered":"<h3>Descripci\u00f3n<\/h3><p><strong>Caracter\u00edsticas del producto:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Especificaci\u00f3n<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 320 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 440 4P<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25VG 690 4P<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Clasificaci\u00f3n SPD seg\u00fan EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2 + Tipo 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2 + Tipo 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Tipo 1 + Tipo 2 + Tipo 3<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Clasificaci\u00f3n SPD seg\u00fan IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Clase I + Clase II + Clase III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Clase I + Clase II + Clase III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Clase I + Clase II + Clase III<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tensi\u00f3n nominal de funcionamiento<\/td>\n<td height=\"32\">Naciones Unidas<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250V\/440V(50\/60Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250V\/440V(50\/60Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400V\/690V(50\/60Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">M\u00e1x. funcionamiento continuo a.c. Voltaje<\/td>\n<td height=\"32\">uc<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">690 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corriente de impulso de rayo (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corriente de descarga total (10\/350\u03bcs)<\/td>\n<td height=\"32\">total<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corriente de descarga nominal (8\/20\u03bcs)<\/td>\n<td height=\"32\">En<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">30ka<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">M\u00e1x. corriente de descarga (8\/20\u03bcs)<\/td>\n<td height=\"32\">imax<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Cantidad de carga el\u00e9ctrica<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12.5As<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Energ\u00eda espec\u00edfica<\/td>\n<td height=\"32\">W\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nivel de protecci\u00f3n de voltaje<\/td>\n<td height=\"32\">Arriba<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,5kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,8kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22642,5kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Clasificaci\u00f3n de corriente de cortocircuito a.c.<\/td>\n<td height=\"32\">isccr<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA eficaces<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA eficaces<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA eficaces<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">M\u00e1x. fusible de respaldo<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Soporta TOV de sobretensi\u00f3n temporal<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400V\/5seg.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">580V\/5seg.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">800V\/5seg.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Fallo seguro TOV por sobretensi\u00f3n temporal<\/td>\n<td height=\"32\">Utah<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">765V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1000V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Corriente de fuga<\/td>\n<td height=\"32\">ipe<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ninguno<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ninguno<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Ninguno<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tiempo de respuesta<\/td>\n<td height=\"32\">ej\u00e9rcito de reserva<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100 ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100 ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u2264100 ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Rango de temperatura de funcionamiento<\/td>\n<td height=\"32\">Tu<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<\/tr>\n<tr>\n<td>Estado de funcionamiento\/indicaci\u00f3n de fallo<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">verde\/rojo<\/td>\n<td style=\"text-align: center;\">verde\/rojo<\/td>\n<td style=\"text-align: center;\">verde\/rojo<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">\u00c1rea de secci\u00f3n transversal (M\u00edn.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">\u00c1rea de secci\u00f3n transversal (m\u00e1x.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Para montaje en<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Carril DIN de 35 mm<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Material del recinto<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Termopl\u00e1stico UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Grado de protecci\u00f3n<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">C\u00f3digo de pedido<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17261<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17273<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17285<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">C\u00f3digo de pedido (Con se\u00f1alizaci\u00f3n remota)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17262<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17274<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17286<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Caracter\u00edsticas:<\/strong><\/p>\n<p>Se puede utilizar en sistemas TN-S<\/p>\n<p>Componentes potentes, adecuados para todo tipo de sistemas de energ\u00eda comunes.<\/p>\n<p>El descargador de sobretensiones cumple con los requisitos de IEC61643-11.<\/p>\n<p>La unidad est\u00e1 dise\u00f1ada para usarse entre la Zona O y la Zona 1 (seg\u00fan la definici\u00f3n IEC62305-4 de \u00c1rea de protecci\u00f3n contra rayos).<\/p>\n<p>El producto se utiliza principalmente para la protecci\u00f3n Clase I del sistema el\u00e9ctrico.<\/p>\n<p>El producto tiene principalmente una forma de onda 10\/350, hasta 25 KA.<\/p>\n<p>Instalado en la distribuci\u00f3n principal de energ\u00eda.<\/p>\n<p><strong>Solicitud:<\/strong><\/p>\n<p>\u2022 El producto se utiliza principalmente para la protecci\u00f3n primaria del sistema el\u00e9ctrico.<\/p>\n<p>\u2022 Descargador combinado de corrientes de rayo y sobretensiones, precableado y optimizado para aplicaciones para sistemas TN-S.<\/p>\n<p>\u2022 Instalado en la caja de distribuci\u00f3n de energ\u00eda principal.<\/p>\n<p>\u2022 Acostumbrado a la industria y la automatizaci\u00f3n, instalaciones comerciales y residenciales, telecomunicaciones, TI y centros de datos, tratamiento de agua, redes inteligentes y medici\u00f3n de BT, energ\u00eda fotovoltaica y e\u00f3lica, etc.<\/p>\n<p><strong>Instalaci\u00f3n:<\/strong><\/p>\n<p>\u2022 Se debe cortar la energ\u00eda antes de la instalaci\u00f3n. Est\u00e1 prohibido el funcionamiento en vivo.<\/p>\n<p>\u2022 Se recomienda conectar un fusible o disyuntor en serie en el extremo frontal de la protecci\u00f3n contra sobretensiones.<\/p>\n<p>\u2022 El SPD se instala en paralelo en el extremo de entrada de la fuente de alimentaci\u00f3n de la caja de distribuci\u00f3n del edificio o en la sala de equipos. El producto est\u00e1 instalado en el tipo de riel gu\u00eda. Si las condiciones lo permiten, se puede adoptar el modo de conexi\u00f3n Kevin.<\/p>\n<p>\u2022 Durante la instalaci\u00f3n, conecte el dispositivo seg\u00fan el diagrama de instalaci\u00f3n, donde L es la l\u00ednea de fase, N es la l\u00ednea neutra y PE es la l\u00ednea de tierra. No desconectes el dispositivo. Una vez completada la instalaci\u00f3n, encienda el disyuntor autom\u00e1tico y verifique si el estado de funcionamiento es normal.<\/p>\n<p>\u2022 Cuando el SPD est\u00e9 en uso, verifique peri\u00f3dicamente el estado de la ventana de visualizaci\u00f3n de fallas. Si la ventana de visualizaci\u00f3n de fallas est\u00e1 roja o el terminal remoto emite una se\u00f1al de alarma, indica que el SPD est\u00e1 defectuoso y debe repararse o reemplazarse a tiempo.<\/p>\n<p>\u2022 Adecuado para funcionamiento en interiores, como instalado en exteriores, debe estar equipado con una carcasa impermeable.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1620\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25VG-4P-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"parent":0,"menu_order":91,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-965","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/product\/965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/media?parent=965"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/product_category?post=965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}