{"id":791,"date":"2023-12-19T16:19:00","date_gmt":"2023-12-19T08:19:00","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=791"},"modified":"2024-09-05T16:35:57","modified_gmt":"2024-09-05T08:35:57","slug":"en-62305-protection-against-lightning","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/es\/blog\/en-62305-protection-against-lightning\/","title":{"rendered":"EN 62305 Protecci\u00f3n contra el rayo"},"content":{"rendered":"The EN 62305 standard series specifically cover the protection against lightning to structures, their contents, persons and livestock.\r\n\r\nEN 62305 accepts that we now live in the electronic age, making LEMP (Lightning Electromagnetic Impulse) protection for electronic and electrical systems an integral part of the standard through EN 62305-4. LEMP is the term given to the overall electromagnetic effects of lightning, including conducted surges (transient overvoltage and currents) and radiated electromagnetic field effects.\r\n\r\nEN 62305 \u2013 4 categorizes the source of damage, type of damage and the type of loss.\r\n\r\n<strong>Fuentes de da\u00f1o<\/strong>\r\n\r\nLos da\u00f1os que pueden causar los rayos se subdividen en:\r\n<ul>\r\n \t<li>Da\u00f1o a una estructura (incluidas todas las l\u00edneas el\u00e9ctricas a\u00e9reas y enterradas entrantes conectadas a la estructura)<\/li>\r\n \t<li>Da\u00f1os a un servicio (en este caso el servicio forma parte de las redes de telecomunicaciones, datos, suministro el\u00e9ctrico, agua, gas y distribuci\u00f3n de combustibles).<\/li>\r\n<\/ul>\r\n<img class=\"wp-image-17873 size-medium aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/11-400x271.png\" alt=\"\" width=\"400\" height=\"271\" \/>\r\n\r\n<strong>Tipos de da\u00f1o<\/strong>\r\n\r\nCada fuente de da\u00f1o puede resultar en uno o m\u00e1s de tres tipos de da\u00f1o. Los posibles tipos de da\u00f1os se identifican de la siguiente manera:\r\n<ul>\r\n \t<li>D1 Lesiones de personas o ganado por tensiones de paso y de contacto<\/li>\r\n \t<li>D2 Da\u00f1o f\u00edsico (incendio, explosi\u00f3n, destrucci\u00f3n mec\u00e1nica, liberaci\u00f3n de sustancias qu\u00edmicas) debido a los efectos de la corriente del rayo, incluidas las chispas<\/li>\r\n \t<li>D3 Falla de sistemas internos por Impulso Electromagn\u00e9tico de Rayo (LEMP).<\/li>\r\n<\/ul>\r\n<strong>tipos de perdida<\/strong>\r\n\r\nLos siguientes tipos de p\u00e9rdidas pueden resultar de da\u00f1os debidos a rayos:\r\n<ul>\r\n \t<li>L1 P\u00e9rdida de vidas humanas<\/li>\r\n \t<li>L2 P\u00e9rdida de servicio al p\u00fablico<\/li>\r\n \t<li>L3 P\u00e9rdida del patrimonio cultural<\/li>\r\n \t<li>L4 P\u00e9rdida de valor econ\u00f3mico<\/li>\r\n<\/ul>\r\nThe relationships of all of the above parameters:\r\n\r\nThe relationships of all of the above parameters:\r\n<table border=\"1\" cellspacing=\"0\">\r\n<tbody>\r\n<tr class=\"firstRow\">\r\n<td valign=\"top\" width=\"142\">Punto de ataque<\/td>\r\n<td valign=\"top\" width=\"142\">Fuente del da\u00f1o<\/td>\r\n<td valign=\"top\" width=\"142\">Tipo de da\u00f1o<\/td>\r\n<td valign=\"top\" width=\"142\">Tipo de p\u00e9rdida<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Estructura<\/td>\r\n<td valign=\"top\" width=\"142\">T1<\/td>\r\n<td valign=\"top\" width=\"142\">D1&nbsp;\r\n\r\nD2\r\n\r\nD3<\/td>\r\n<td valign=\"top\" width=\"142\">L1, L4**&nbsp;\r\n\r\nL1, L2, L3, L4\r\n\r\nL1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Cerca de una estructura<\/td>\r\n<td valign=\"top\" width=\"142\">T2<\/td>\r\n<td valign=\"top\" width=\"142\">D3<\/td>\r\n<td valign=\"top\" width=\"142\">L1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Servicio conectado a la estructura<\/td>\r\n<td valign=\"top\" width=\"142\">T3<\/td>\r\n<td valign=\"top\" width=\"142\">D1&nbsp;\r\n\r\nD2\r\n\r\nD3<\/td>\r\n<td valign=\"top\" width=\"142\">L1,L4**&nbsp;\r\n\r\nL1, L2, L3, L4\r\n\r\nL1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">cerca de un servicio<\/td>\r\n<td valign=\"top\" width=\"142\">T4<\/td>\r\n<td valign=\"top\" width=\"142\">D3<\/td>\r\n<td valign=\"top\" width=\"142\">L1*, L2, L4<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n* Only for structures with risk of explosion and for hospitals or other structures where failures of internal systems immediately endangers human life.\r\n\r\n** Only for properties where animals may be lost.\r\n\r\nLEMP damage is so prevalent that it is identified as one of the specific types (D3) against which protection should be provided and can occur from ALL strike points to the structure or connected services \u2013 direct or indirect. This extended approach also takes into account the danger of fire or explosion associated with services connected to the structure, e.g. power, telecoms and other metallic lines.\r\n\r\nEN 62305 makes it clear that structural lightning protection must no longer be considered in isolation from transient overvoltage\/surge protection and given that lightning from all strikes points, direct or indirect, to the structure or connected services creates a risk from transients, SPDs are a vital means of protection whether structural lightning protection is present or not.\r\n\r\n<strong>Formas de onda de corriente y voltaje.<\/strong>\r\n\r\nEN 62305 takes account of protection measures on metallic service lines (typically power, signal and telecom lines) using transient overvoltage or Surge Protection Devices (SPDs) against both direct lightning strikes as well as the more common indirect lightning strikes and switching transients. Standards such as the EN 61643 series define the characteristics of lightning currents and voltages to enable reliable and repeatable testing of SPDs (as well as lightning protection components). Although these waveforms may differ from actual transients, the standardized forms are based upon years of observation and measurement (and in some cases simulation). In general they provide a fair approximation of the real world transient.\r\n\r\nTransient waveforms have a fast rising edge and a longer tail. They are described through their peak value (or magnitude), rise time and their duration (or fall time). The duration is measured as the time taken for the test transient to decay to half its peak value.\r\n\r\nThe figures below illustrate the common current and voltage waveforms that are used to test SPDs for mains, signal and telecom lines.\r\n\r\n<img class=\"wp-image-17874 size-medium aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-400x239.png\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-400x239.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-768x459.png 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-600x358.png 600w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-150x90.png 150w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12.png 1147w\" alt=\"\" width=\"400\" height=\"239\" \/>\r\n\r\n<strong>Huelgas directas<\/strong>\r\n\r\nLos rayos directos pueden inyectar corrientes de rayo parciales de la forma de onda de 10\/350 \u03bcs en un sistema donde una estructura con un sistema de protecci\u00f3n contra rayos estructural recibe un impacto directo (Fuente S1) o donde un rayo cae directamente sobre una l\u00ednea de servicio a\u00e9rea (Fuente S3).\r\n\r\n<strong>Golpes indirectos<\/strong>\r\n\r\nRemote or indirect lightning flashes near the structure (Source S2) or near a connected service to the structure (Source S4) of up to 1km radius away (and hence far more common) are represented by the 8\/20\u03bcs waveform. Induced surges from direct lightning flashes and switching sources are also represented by this waveform. With a much shorter decay or fall time relative to the 10\/350\u03bcs waveform, the 8\/20\u03bcs waveform presents significantly less energy (for an equivalent peak current) but is still devastating enough to damage electrical and electronic equipment.\r\n\r\nEN 62305-1 recognizes that failure of internal systems (Damage Type D3) due to Lightning Electromagnetic Impulse (LEMP) is possible from all points of strike to the structure or service \u2013 direct or indirect (all Sources: S1, S2, S3 and S4).\r\n\r\n<strong>Medidas de protecci\u00f3n contra sobretensiones (SPM)<\/strong>\r\n\r\nEN 62305-4 describes a number of measures to minimize the severity of transient overvoltage caused by lightning and electrical switching.\r\n\r\nKey and basic protection measures are:\r\n<ul>\r\n \t<li>Puesta a tierra y uni\u00f3n<\/li>\r\n \t<li>Blindaje electromagn\u00e9tico y guiado de l\u00edneas.<\/li>\r\n \t<li>Dispositivos de protecci\u00f3n contra sobretensiones coordinados<\/li>\r\n<\/ul>\r\nOtras medidas de protecci\u00f3n adicionales incluyen:\r\n<ul>\r\n \t<li>Ampliaciones al LPS estructural.<\/li>\r\n \t<li>Ubicaci\u00f3n del equipo<\/li>\r\n \t<li>Uso de cables de fibra \u00f3ptica (protecci\u00f3n por aislamiento)<\/li>\r\n<\/ul>\r\nSPMs also have to operate within and withstand the environment in which they are located considering factors such as temperature, humidity, vibration, voltage and current.\r\n\r\nSelection of the most suitable SPM is made using the risk assessment in accordance with EN 62305-2 taking into account both technical and economic factors. For example, it may not be practical or cost effective to implement electromagnetic shielding measures in an existing structure so the use of coordinated SPDs may be more suitable. Ideally SPDs are best incorporated at the project design stage, although they can also be readily installed in existing installations.\r\n\r\nTo ensure continuous operation of critical systems even in the event of a direct strike, SPDs are essential and these must be suitably deployed, based on the source of surge and its intensity using the Lightning Protection Zones (LPZ) concept within EN 62305-4.\r\n\r\n<strong>El concepto de zona de protecci\u00f3n contra rayos (LPZ)<\/strong>\r\n\r\nLa protecci\u00f3n contra LEMP se basa en un concepto de Zona de Protecci\u00f3n contra Rayos (LPZ) que divide la estructura en cuesti\u00f3n en una serie de zonas seg\u00fan el nivel de amenaza que representa el LEMP. La idea general es identificar o crear zonas dentro de la estructura donde haya menos exposici\u00f3n a algunos o todos los efectos del rayo y coordinarlos con las caracter\u00edsticas de inmunidad de los equipos el\u00e9ctricos o electr\u00f3nicos instalados dentro de la zona. Las zonas sucesivas soncaracterizado por reducciones significativas en la gravedad de LEMP como resultado de la uni\u00f3n, el blindaje o el uso de SPD.\r\n\r\n<strong>Zonas exteriores:<\/strong>\r\n<ul>\r\n \t<li>LPZ 0A es la zona sujeta a la descarga directa de rayos y, por lo tanto, puede tener que transportar toda la corriente del rayo. Esta suele ser el \u00e1rea del techo de una estructura sin protecci\u00f3n estructural contra rayos. Aqu\u00ed se produce todo el campo electromagn\u00e9tico.<\/li>\r\n \t<li>LPZ 0B es el \u00e1rea que no est\u00e1 sujeta a la ca\u00edda directa de rayos y normalmente son las paredes laterales de una estructura o un techo con protecci\u00f3n estructural contra rayos. Sin embargo, aqu\u00ed todav\u00eda se produce todo el campo electromagn\u00e9tico y pueden producirse corrientes de rayo conducidas parciales o inducidas y sobretensiones de conmutaci\u00f3n.<\/li>\r\n<\/ul>\r\n<strong>Zonas internas:<\/strong>\r\n<ul>\r\n \t<li>LPZ 1 es el \u00e1rea interna que est\u00e1 sujeta a corrientes parciales de rayo. Las corrientes de rayo conducidas y\/o las sobretensiones de conmutaci\u00f3n se reducen en comparaci\u00f3n con las zonas exteriores LPZ 0A, LPZ 0B, al igual que el campo electromagn\u00e9tico, si se utilizan medidas de protecci\u00f3n adecuadas. Esta suele ser el \u00e1rea donde los servicios ingresan a la estructura o donde se encuentra el tablero de distribuci\u00f3n principal.<\/li>\r\n \t<li>LPZ 2 es un \u00e1rea interna que se encuentra adem\u00e1s dentro de la estructura donde los restos de corrientes de impulso de rayo y\/o sobretensiones de conmutaci\u00f3n se reducen en comparaci\u00f3n con LPZ 1. De manera similar, el campo electromagn\u00e9tico se reduce a\u00fan m\u00e1s si se emplean medidas de blindaje adecuadas. Por lo general, se trata de una sala protegida o, para la alimentaci\u00f3n de red, en el \u00e1rea del tablero de distribuci\u00f3n secundaria.<\/li>\r\n<\/ul>","protected":false},"featured_media":792,"parent":0,"menu_order":180,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-791","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"The EN 62305 standard series specifically cover the protection against lightning to structures, their contents, persons and livestock.","txt":"The EN 62305 standard series specifically cover the protection against lightning to structures, their contents, persons and livestock.\r\n\r\nEN 62305 accepts that we now live in the electronic age, making LEMP (Lightning Electromagnetic Impulse) protection for electronic and electrical systems an integral part of the standard through EN 62305-4. LEMP is the term given to the overall electromagnetic effects of lightning, including conducted surges (transient overvoltage and currents) and radiated electromagnetic field effects.\r\n\r\nEN 62305 \u2013 4 categorizes the source of damage, type of damage and the type of loss.\r\n\r\n<strong>Sources of damage<\/strong>\r\n\r\nDamage that can be caused by lightning is sub-divided into:\r\n<ul>\r\n \t<li>Damage to a structure (including all incoming electrical overhead and buried lines connected to the structure)<\/li>\r\n \t<li>Damage to a service (service in this instance being part of telecommunication, data, electrical supply, water, gas and fuel distribution networks).<\/li>\r\n<\/ul>\r\n<img class=\"wp-image-17873 size-medium aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/11-400x271.png\" alt=\"\" width=\"400\" height=\"271\" \/>\r\n\r\n<strong>Types of damage<\/strong>\r\n\r\nEach source of damage may result in one or more of three types of damage. The possible types of damage are identified as follows:\r\n<ul>\r\n \t<li>D1 Injury of persons or livestock due to step and touch voltages<\/li>\r\n \t<li>D2 Physical damage (fire, explosion, mechanical destruction, chemical release) due to lightning current effects including sparking<\/li>\r\n \t<li>D3 Failure of internal systems due to Lightning Electromagnetic Impulse (LEMP).<\/li>\r\n<\/ul>\r\n<strong>Types of loss<\/strong>\r\n\r\nThe following types of loss may result from damage due to lightning:\r\n<ul>\r\n \t<li>L1 Loss of human life<\/li>\r\n \t<li>L2 Loss of service to the public<\/li>\r\n \t<li>L3 Loss of cultural heritage<\/li>\r\n \t<li>L4 Loss of economic value<\/li>\r\n<\/ul>\r\nThe relationships of all of the above parameters:\r\n\r\nThe relationships of all of the above parameters:\r\n<table border=\"1\" cellspacing=\"0\">\r\n<tbody>\r\n<tr class=\"firstRow\">\r\n<td valign=\"top\" width=\"142\">Point of strike<\/td>\r\n<td valign=\"top\" width=\"142\">Source of\u00a0damage<\/td>\r\n<td valign=\"top\" width=\"142\">Type of\u00a0damage<\/td>\r\n<td valign=\"top\" width=\"142\">Type of\u00a0loss<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Structure<\/td>\r\n<td valign=\"top\" width=\"142\">S1<\/td>\r\n<td valign=\"top\" width=\"142\">D1&nbsp;\r\n\r\nD2\r\n\r\nD3<\/td>\r\n<td valign=\"top\" width=\"142\">L1, L4**&nbsp;\r\n\r\nL1, L2, L3, L4\r\n\r\nL1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Near a\u00a0Structure<\/td>\r\n<td valign=\"top\" width=\"142\">S2<\/td>\r\n<td valign=\"top\" width=\"142\">D3<\/td>\r\n<td valign=\"top\" width=\"142\">L1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Service connected\u00a0to the structure<\/td>\r\n<td valign=\"top\" width=\"142\">S3<\/td>\r\n<td valign=\"top\" width=\"142\">D1&nbsp;\r\n\r\nD2\r\n\r\nD3<\/td>\r\n<td valign=\"top\" width=\"142\">L1,L4**&nbsp;\r\n\r\nL1, L2, L3, L4\r\n\r\nL1*, L2, L4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td valign=\"top\" width=\"142\">Near a service<\/td>\r\n<td valign=\"top\" width=\"142\">S4<\/td>\r\n<td valign=\"top\" width=\"142\">D3<\/td>\r\n<td valign=\"top\" width=\"142\">L1*, L2, L4<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n* Only for structures with risk of explosion and for hospitals or other structures where failures of internal systems immediately endangers human life.\r\n\r\n** Only for properties where animals may be lost.\r\n\r\nLEMP damage is so prevalent that it is identified as one of the specific types (D3) against which protection should be provided and can occur from ALL strike points to the structure or connected services \u2013 direct or indirect. This extended approach also takes into account the danger of fire or explosion associated with services connected to the structure, e.g. power, telecoms and other metallic lines.\r\n\r\nEN 62305 makes it clear that structural lightning protection must no longer be considered in isolation from transient overvoltage\/surge protection and given that lightning from all strikes points, direct or indirect, to the structure or connected services creates a risk from transients, SPDs are a vital means of protection whether structural lightning protection is present or not.\r\n\r\n<strong>Current and voltage waveforms<\/strong>\r\n\r\nEN 62305 takes account of protection measures on metallic service lines (typically power, signal and telecom lines) using transient overvoltage or Surge Protection Devices (SPDs) against both direct lightning strikes as well as the more common indirect lightning strikes and switching transients. Standards such as the EN 61643 series define the characteristics of lightning currents and voltages to enable reliable and repeatable testing of SPDs (as well as lightning protection components). Although these waveforms may differ from actual transients, the standardized forms are based upon years of observation and measurement (and in some cases simulation). In general they provide a fair approximation of the real world transient.\r\n\r\nTransient waveforms have a fast rising edge and a longer tail. They are described through their peak value (or magnitude), rise time and their duration (or fall time). The duration is measured as the time taken for the test transient to decay to half its peak value.\r\n\r\nThe figures below illustrate the common current and voltage waveforms that are used to test SPDs for mains, signal and telecom lines.\r\n\r\n<img class=\"wp-image-17874 size-medium aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-400x239.png\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-400x239.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-768x459.png 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-600x358.png 600w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12-150x90.png 150w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/12.png 1147w\" alt=\"\" width=\"400\" height=\"239\" \/>\r\n\r\n<strong>Direct strikes<\/strong>\r\n\r\nDirect lightning can inject partial lightning currents of the 10\/350\u03bcs waveform into a system where a structure with a structural Lightning Protection System receives a direct strike (Source S1) or where lightning directly strikes an overhead service line (Source S3).\r\n\r\n<strong>Indirect strikes<\/strong>\r\n\r\nRemote or indirect lightning flashes near the structure (Source S2) or near a connected service to the structure (Source S4) of up to 1km radius away (and hence far more common) are represented by the 8\/20\u03bcs waveform. Induced surges from direct lightning flashes and switching sources are also represented by this waveform. With a much shorter decay or fall time relative to the 10\/350\u03bcs waveform, the 8\/20\u03bcs waveform presents significantly less energy (for an equivalent peak current) but is still devastating enough to damage electrical and electronic equipment.\r\n\r\nEN 62305-1 recognizes that failure of internal systems (Damage Type D3) due to Lightning Electromagnetic Impulse (LEMP) is possible from all points of strike to the structure or service \u2013 direct or indirect (all Sources: S1, S2, S3 and S4).\r\n\r\n<strong>Surge Protection Measures (SPM)<\/strong>\r\n\r\nEN 62305-4 describes a number of measures to minimize the severity of transient overvoltage caused by lightning and electrical switching.\r\n\r\nKey and basic protection measures are:\r\n<ul>\r\n \t<li>Earthing and bonding<\/li>\r\n \t<li>Electromagnetic shielding and line routing<\/li>\r\n \t<li>Coordinated Surge Protective Devices<\/li>\r\n<\/ul>\r\nFurther additional protection measures include:\r\n<ul>\r\n \t<li>Extensions to the structural LPS<\/li>\r\n \t<li>Equipment location<\/li>\r\n \t<li>Use of fiber optic cables (protection by isolation)<\/li>\r\n<\/ul>\r\nSPMs also have to operate within and withstand the environment in which they are located considering factors such as temperature, humidity, vibration, voltage and current.\r\n\r\nSelection of the most suitable SPM is made using the risk assessment in accordance with EN 62305-2 taking into account both technical and economic factors. For example, it may not be practical or cost effective to implement electromagnetic shielding measures in an existing structure so the use of coordinated SPDs may be more suitable. Ideally SPDs are best incorporated at the project design stage, although they can also be readily installed in existing installations.\r\n\r\nTo ensure continuous operation of critical systems even in the event of a direct strike, SPDs are essential and these must be suitably deployed, based on the source of surge and its intensity using the Lightning Protection Zones (LPZ) concept within EN 62305-4.\r\n\r\n<strong>The Lightning Protection Zone (LPZ) concept<\/strong>\r\n\r\nProtection against LEMP is based on a concept of the Lightning Protection Zone (LPZ) that divides the structure in question into a number of zones according to the level of threat posed by the LEMP. The general idea is to identify or create zones within the structure where there is less exposure to some or all of the effects of lightning and to coordinate these with the immunity characteristics of the electrical or electronic equipment installed within the zone. Successive zones are characterized by significant reductions in LEMP severity as a result of bonding, shielding or the use of SPDs.\r\n\r\n<strong>External zones:<\/strong>\r\n<ul>\r\n \t<li>LPZ 0A is the area subject to direct lightning strokes and therefore may have to carry up to the full lightning current. This is typically the roof area of a structure without structural lightning protection. The full electromagnetic field occurs here.<\/li>\r\n \t<li>LPZ 0B is the area not subject to direct lightning strokes and is typically the sidewalls of a structure or a roof with structural lightning protection. However the full electromagnetic field still occurs here and conducted partial or induced lightning currents and switching surges can occur here.<\/li>\r\n<\/ul>\r\n<strong>Internal zones:<\/strong>\r\n<ul>\r\n \t<li>LPZ 1 is the internal area that is subject to partial lightning currents. The conducted lightning currents and\/or switching surges are reduced compared with the external zones LPZ 0A, LPZ 0B as is the electromagnetic field if suitable shielding measures are employed. This is typically the area where services enter the structure or where the main power switchboard is located.<\/li>\r\n \t<li>LPZ 2 is an internal area that is further located inside the structure where the remnants of lightning impulse currents and\/or switching surges are reduced compared with LPZ 1. Similarly the electromagnetic field is further reduced if suitable shielding measures are employed. This is typically a screened room or, for mains power at the sub-distribution board area.<\/li>\r\n<\/ul>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/blog\/791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/media\/792"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/media?parent=791"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/es\/wp-json\/wp\/v2\/blog_category?post=791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}