BR-80 3P Type 2 80kA Surge Protective Device For TN-C

Λάβετε μια προσφορά
Περιγραφή

Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-80 150 3P BR-80 275 3P BR-80 320 3P BR-80 385 3P
SPD classification according to EN61643-11 Τύπος 2 Τύπος 2 Τύπος 2 Τύπος 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 40 kA 40 kA 40 kA 40 kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 80kA 80kA 80kA 80kA
Επίπεδο προστασίας τάσης Επάνω ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
Voltage protection level 5kA Επάνω ≤0.6kV ≤1.0kV ≤1.1kV ≤1.2kV
Max. backup fuse 160A gG 160A gG 160A gG 160A gG
Short-circuit withstand capacity Isccr 25 kA 25 kA 25 kA 25 kA
Temporary overvoltage TOV-withstand UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure UT 230V/120min. 440V/120min. 520V/120min. 650V/120min.
Χρόνος απόκρισης tA ≤25ns ≤25ns ≤25ns ≤25ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Thermoplastic   UL94-V0
Βαθμός προστασίας IP20 IP20 IP20 IP20
Order Code B18268 B18270 B18272 B18274
Order Code (With remote signaling) B18269 B18271 B18273 B18275

Χαρακτηριστικά:

Visual status display

Labeled connections

Type 2 (class II/C) for main boards, distribution boards and consumer units.

Available with and without remote signalling contacts.

1 pole up to 4 poles protected.

BR-80 consists of a high performance varistor block with thermal disconnection device. The plug-in module/base design facilitates replacement of a failed module in situ without the need to remove system wiring.

Solutions to meet IEC 61643-1 and EN 61643-11

Εφαρμογή:

Distribution switch board located downstream from a Type 1 Lightning Current Arrester.

Protecting them from direct and indirect lightning impulse and other transient overvoltage.

Protects low-voltage systems against overvoltage triggered by lightning strikes or grid switching operations.

Ideal for industrial applications.

At the origin of the electrical installation in the main switchboard, in areas where electromagnetic fields caused by lightning currents are dominant (excluding a direct strike).

Suitable for TN-C systems.

Preventing the spread of medium overvoltage (Up) in the electrical installation and protecting equipment that is connected to it.

 

ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.