Χαρακτηριστικά προϊόντος:
| Προσδιορισμός | BR-7M 150 3P | BR-7M 275 3P | BR-7M 320 3P | |
| SPD classification according to EN61643-11 | Type 1 + Type 2 | Type 1 + Type 2 | Type 1 + Type 2 | |
| SPD classification according to IEC61643-11 | Class I + Class II | Class I + Class II | Class I + Class II | |
| Max. continuous operating a.c. voltage | Uc | 150V(50/60Hz) | 275V(50/60Hz) | 320V(50/60Hz) |
| Lightning impulse current (10/350μs) | Iimp | 7kA | 7kA | 7kA |
| Ονομαστικό ρεύμα εκφόρτισης (8/20μs) | Σε | 20 kA | 20 kA | 20 kA |
| Μέγ. ρεύμα εκφόρτισης (8/20μs) | Imax | 50 kA | 50 kA | 50 kA |
| Specific energy | W/R | 12.25kJ/Ω | 12.25kJ/Ω | 12.25kJ/Ω |
| Επίπεδο προστασίας τάσης | Επάνω | ≤0.8kV | ≤1.3kV | ≤1.5kV |
| Short-circuit current rating a.c. | Isccr | 25kA rms | 25kA rms | 25kA rms |
| Max. backup fuse | 125A gG | 125A gG | 125A gG | |
| Temporary overvoltage TOV-withstand | UT(L-N) | 180V/5sec. | 335V/5sec. | 400V/5sec. |
| Temporary overvoltage TOV-safe failure | UT(L-N) | 230V/120min. | 440V/120min. | 520V/120min. |
| Χρόνος απόκρισης | tA | ≤25ns | ≤25ns | ≤25ns |
| Εύρος θερμοκρασίας λειτουργίας | Tu | -40℃-80℃ | -40℃-80℃ | -40℃-80℃ |
| Operating state/fault indication | green/red | green/red | green/red | |
| Εμβαδόν διατομής (ελάχ.) | 4mm² | 4mm² | 4mm² | |
| Εμβαδόν διατομής (Μέγ.) | 35 mm² | 35 mm² | 35 mm² | |
| Για τοποθέτηση σε | Ράγα Din 35mm | |||
| Υλικό περιβλήματος | Θερμοπλαστικό UL94-V0 | |||
| Βαθμός προστασίας | IP20 | IP20 | IP20 | |
| Order Code | B17306 | B17308 | B17310 | |
| Order Code (With remote signaling) | B17307 | B17309 | B17311 | |
Χαρακτηριστικά:
Equipped with a thermal disconnection.
BR-7M 3P is built with a plug-in module and fixed base, which allows an easy and fast maintenance.
DIN rail mounted surge protector is easy to install in any standardized distribution pane or control cabinets.
It is equipped with an internal thermal safety which will disconnect the unit from the AC network in case of the end of life. This disconnection will be indicated by the turn-on of the red mechanical indicator in the front.
Εφαρμογή:
BR-7M AC SPD is suitably used in the TN-C power supply system of AC 50/60HZ.
Suitable for system power protection, such as power distribution cabinet, switch cabinet, switch cabinet, AC distribution board, etc.
SPD to protect from direct and indirect lightning impulse and other transient over voltage.
Εγκατάσταση:
The protector is installed with standard 35mm track.
The protector is connected by 4 ~ 35mm copper wire.
No need to adjust after the protector is installed as required.
During operation, regularly check whether the module is red; replace the failed component in time.
Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.