BR-50GR 2P Type 1 50kA Surge Arrester for TNS

Λάβετε μια προσφορά
Περιγραφή

Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-50GR 150 2P BR-50GR 275 2P BR-50GR 350 2P
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating voltage Ηνωμένα Έθνη 120V(50/60Hz) 230V(50/60Hz) 250V(50/60Hz)
Max. continuous operating a.c. voltage Uc 150V(50/60Hz) 275V(50/60Hz) 350V(50/60Hz)
Lightning impulse current (10/350μs) Iimp 50 kA 50 kA 50 kA
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 50 kA 50 kA 50 kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 160kA 160kA 160kA
Quantity of electric charge Q 25As 25As 25As
Specific energy W/R 625kJ/Ω 625kJ/Ω 625kJ/Ω
Επίπεδο προστασίας τάσης Επάνω ≤1.5kV ≤1.5kV ≤1.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 350A gG 350A gG 350A gG
Temporary overvoltage TOV-withstand UT 230V/120min. 440V/120min. 580V/120min.
Χρόνος απόκρισης tA ≤100ns ≤100ns ≤100ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Θερμοπλαστικό UL94-V0
Βαθμός προστασίας IP20 IP20 IP20
Order Code B17162 B18127 B17188
Order Code (With remote signaling) B17163 B18128 B17189

Χαρακτηριστικά:

BR-50GR 2P is suitable for TN system.

Poles number: 2P.

Width of one pole: 36mm.

Uc 150V / 275V /350V can be achieved.

Fault indication via red mark in the inspection window.

35mm DIN rail mountable.

With remote signaling contact for control device for your option.

In accordance with EN / IEC 61643.

High security performance.

Easy maintenance.

Red indicates broken, replacement notice, which is clear and easy distinguished.

Εφαρμογή:

Used in the main distribution boards, for use primarily on mains power distribution systems to protect connected facility from transient overvoltage.

Suitable for the low voltage main power distribution cabinet/box of buildings, and the facility connected between single phase AC power supply and system in parallel.

Use of attention:

1. The grounding path should be as short as possible, and the length should not exceed 1.5 meters.

2. When installing, pay attention to cables coming in and out of surge protective devices, so as to avoid the two coupling of surge.

3. The protected equipment must have good grounding, and the grounding impedance is in accordance with the relevant national standards.

4. After correct installation, it can work steadily for a long time. If it is found that the transmission performance of the system is reduced or the signal is interrupted due to the cause of surge protection, it should be maintained or replaced in time.

 

ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.