BR-40VG 3+1 Type 2 40kA Lightning Protector

Λάβετε μια προσφορά
Περιγραφή

Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-40VG 150 3+1 BR-40VG 275 3+1 BR-40VG 320 3+1 BR-40VG 385 3+1 BR-40VG 440 3+1
SPD classification according to EN61643-11 Τύπος 2 Τύπος 2 Τύπος 2 Τύπος 2 Τύπος 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255 V 255 V 255 V 255 V 255 V
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 20 kA 20 kA 20 kA 20 kA 20 kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 40 kA 40 kA 40 kA 40 kA 40 kA
Voltage protection level (L-N) Επάνω ≤1.3kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level (N-PE) Επάνω ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 100A gG 100A gG 100A gG 100A gG 100A gG
Short-circuit withstand capacity Isccr 25 kA 25 kA 25 kA 25 kA 25 kA
Temporary overvoltage TOV-withstand (L-N) UT 180V/5sec. 335V/5sec. 400V/5sec. 500V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 230V/120min. 440V/120min. 520V/120min. 650V/120min. 765V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Thermoplastic   UL94-V0
Βαθμός προστασίας IP20 IP20 IP20 IP20 IP20
Order Code B17510 B17522 B17534 B17546 B17558
Order Code (With remote signaling) B17511 B17523 B17535 B17547 B17559

Χαρακτηριστικά:

Consistent plug ability(even for N/PE spark gap)

It is compact devices designed to protect 3-phase+neutral networks at the main switchboard.

BR-40VG series Surge Protection are designed to protect against lighting surge voltages.

The protection circuitry is based on high energy varistor with thermal disconnection devices.

Maximum current of endure the lightning stroke 40KA.

There is an indicator on the cartridges to signal failure mode.

Thermal disconnect device for each individual connector

With or without floating remote indication contact

Time of response<100ns.

Din rail mountable (35 mm)

The color of the visible window shows operating status, green means normal, red means abnormal.

Conform to IEC61643-11 standards

AC Type 2 SPD is the secondary protection system for all low voltage electric installations.

This is installed in to each electrical switch boards and prevents the spread of surges in the electric systems, protecting the loads.

Εφαρμογή:

Suitable for system power protection, such as power distribution cabinet, switch cabinet, switch cabinet, AC distribution board, etc.

Protection of terminal devices.

BR-40VG AC SPD to protect from direct and indirect lightning impulse and other transient over voltage.

Used for protection against electrical transients.

 

ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.