Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-25VG 320 4P BR-25VG 440 4P BR-25VG 690 4P
SPD classification according to EN61643-11 Type 1 + Type 2 +Type 3 Type 1 + Type 2 +Type 3 Type 1 + Type 2 +Type 3
SPD classification according to IEC61643-11 Class I + Class II + Class III Class I + Class II + Class III Class I + Class II + Class III
Nominal operating voltage Ηνωμένα Έθνη 250V/440V(50/60Hz) 250V/440V(50/60Hz) 400V/690V(50/60Hz)
Max. continuous operating a.c. voltage Uc 320V(50/60Hz) 440V(50/60Hz) 690V(50/60Hz)
Lightning impulse current (10/350μs) Iimp 25 kA 25 kA 25 kA
Total discharge current (10/350μs) Itotal 100kA 100kA 100kA
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 30kA 30kA 30kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 100kA 100kA 100kA
Quantity of electric charge Q 12.5As 12.5As 12.5As
Specific energy W/R 156kJ/Ω 156kJ/Ω 156kJ/Ω
Επίπεδο προστασίας τάσης Επάνω ≤1.5kV ≤1.8kV ≤2.5kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 200A gG 200A gG 200A gG
Temporary overvoltage TOV-withstand UT 400V/5sec. 580V/5sec. 800V/5sec.
Temporary overvoltage TOV-safe failure UT 520V/120min. 765V/120min. 1000V/120min.
Leakage current Ipe None None None
Χρόνος απόκρισης tA ≤100ns ≤100ns ≤100ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Θερμοπλαστικό UL94-V0
Βαθμός προστασίας IP20 IP20 IP20
Order Code B17261 B17273 B17285
Order Code (With remote signaling) B17262 B17274 B17286

Χαρακτηριστικά:

Can be used in TN-S systems

Powerful components, suitable for all kinds of common power systems.

The surge arrester meets the requirements of IEC61643-11

The unit is designed to be used between Zone O and Zone 1 (according to IEC62305-4 definition of Lightning Protection Area).

The product is mainly used for the Class I protection of the power system.

The product is mainly 10/350 waveform, up to 25KA

Installed in the main power distribution

Εφαρμογή:

• The product is mainly used for primary protection of power system.

• Application-optimised and prewired combined lightning current and surge arrester for TN-S systems.

• Installed in the main power distribution box.

• Used to Industry and automation, commercial and residential installations, telecom & IT & data centers, water treatment, smart grid & LV metering, photovoltaic and wind etc.

Εγκατάσταση:

• Power must be cut off before installation. Live operation is prohibited.

• It is recommended that a fuse or circuit breaker be connected in series at the front end of the surge protection.

• SPD is installed in parallel at the power supply inlet end of the building distribution box or the equipment room. The product is installed in the guide rail type. If conditions permit, the Kevin connection mode can be adopted.

• During installation, connect the device according to the installation diagram, where L is the phase line,N is the neutral line, and PE is the ground line. Do not misconnect the device. After the installation is complete, turn on the automatic circuit breaker and check whether the working status is normal.

• When the SPD is in use, check the status of the fault display window regularly. If the fault display window is red or the remote terminal outputs an alarm signal, it indicates that the SPD is faulty and should be repaired or replaced in time.

• Suitable for indoor operation, such as installed in the outdoor, must be equipped with waterproof shell.

 

ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.