BR-200 1+1 Type 2 200kA Surge Protective Device For TT And TNS

Λάβετε μια προσφορά
Περιγραφή

Χαρακτηριστικά προϊόντος:

Προσδιορισμός BR-200 275 1+1 BR-200 320 1+1 BR-200 385 1+1
SPD classification according to EN61643-11 Τύπος 2 Τύπος 2 Τύπος 2
SPD classification according to IEC61643-11 Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255 V 255 V 255 V
Ονομαστικό ρεύμα εκφόρτισης (8/20μs) Σε 100kA 100kA 100kA
Μέγ. ρεύμα εκφόρτισης (8/20μs) Imax 200kA 200kA 200kA
Voltage protection level (L-N) Επάνω ≤1.9kV ≤2.1kV ≤2.5kV
Voltage protection level 5kA (L-N) Επάνω ≤0.6kV ≤1.0kV ≤1.2kV
Voltage protection level (N-PE) Επάνω ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 350A gG 350A gG 350A gG
Short-circuit withstand capacity Isccr 25 kA 25 kA 25 kA
Temporary overvoltage TOV-withstand (L-N) UT 335V/5sec. 400V/5sec. 500V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 440V/120min. 520V/120min. 650V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns
Εύρος θερμοκρασίας λειτουργίας Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Εμβαδόν διατομής (ελάχ.) 4mm² 4mm² 4mm²
Εμβαδόν διατομής (Μέγ.) 35 mm² 35 mm² 35 mm²
Για τοποθέτηση σε Ράγα Din 35mm
Υλικό περιβλήματος Thermoplastic   UL94-V0
Βαθμός προστασίας IP20 IP20 IP20
Order Code B17452 B17454 B17456
Order Code (With remote signaling) B17453 B17455 B17457

Χαρακτηριστικά:

1) Big discharger current capacity, low residual voltage, quick response

2) IP20, UL94 V0

3) Lowe leakage current and rate of change

4) Class II / Type 2 surge protective devices.

5) Heat isolation technique, no fire disaster

6) The core parts are metal oxide varistor components with high discharge capacity.

7) Apply special shock fuse pieces, with high reliability

8) Standard compliance: IEC61643-11, EN61643-11

9) With power indicator to display working condition

10) Protecting low voltage devices from surge for TN-S (or TT 1+1 mode as custom-made) power supply systems.

11) Temperature control protective circuit, built-in heat protection, automatic release unit

12) Mount on the 35mm DIN rail.

13) 1+1 protection model(L-N, N-PE), suitable for the poor power grid area

14) Nominal Discharge Current: 100kA

15) Max. Discharge Current: 200kA

16) Exquisite process, can work under the hostile environment for a long time, like acid, alkali, dust, salt fog, wet, etc.

Εφαρμογή:

1) Three phase power SPD is suitable for system power protection, such as switching room, power distribution cabinet, switch cabinet, AC distribution board, etc.

2) For using in the lightning protection zones concept at boundary 1-2.

3) Distribution box with outdoor input in the building and each floor

4) AC power line of house, bank, and telecom tower and so on.

5) AC power surge protective device is used in AC power supply system (50/60Hz) and low-voltage control system to protect from lightning striker and transient over-voltage.

6) Automation machine room, power supply panel of converting station main control room

 

ΕΙΜΑΣΤΕ ΕΔΩ ΓΙΑ ΝΑ ΣΑΣ ΥΠΟΣΤΗΡΙΞΟΥΜΕ!

Περισσότερες πληροφορίες ή προσωπική διαβούλευση; Τα προϊόντα και η τεχνογνωσία μας υπάρχουν για να δώσουν λύσεις.

ΣΧΕΤΙΚΑ ΠΡΟΪΟΝΤΑ
ΣΧΕΤΙΚΑ ΝΕΑ
ΜΠΟΡΕΙ ΕΠΙΣΗΣ ΝΑ ΘΕΛΕΤΕ ΝΑ ΔΕΙΤΕ
ΑΠΟΚΤΗΣΤΕ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΤΥΠΟΥΣ
ΛΥΣΗ ΣΗΜΕΡΑ!
εικόνισμα
εικόνισμα
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.