{"id":920,"date":"2024-09-04T10:57:01","date_gmt":"2024-09-04T02:57:01","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=product&#038;p=920"},"modified":"2026-04-07T13:38:19","modified_gmt":"2026-04-07T05:38:19","slug":"br-25m-31-type-1-25ka-surge-arrester-for-tt-and-tns","status":"publish","type":"product","link":"https:\/\/www.britecelectric.com\/de\/product\/br-25m-31-type-1-25ka-surge-arrester-for-tt-and-tns\/","title":{"rendered":"BR-25M 3+1 Typ 1 25kA \u00dcberspannungsableiter f\u00fcr TT und TNS"},"content":{"rendered":"<h3>Beschreibung<\/h3><p><strong>Produkteigenschaften:<\/strong><\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"firstRow\">\n<td height=\"32\"><strong>Spezifikation<\/strong><\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 150 3+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 275 3+1<\/strong><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\"><strong>BR-25M 320 3+1<\/strong><\/td>\n<\/tr>\n<tr>\n<td height=\"32\">SPD-Klassifizierung gem\u00e4\u00df EN61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + 2 + 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + 2 + 3<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Typ 1 + 2 + 3<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">SPD-Klassifizierung gem\u00e4\u00df IEC61643-11<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasse I + II + III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasse I + II + III<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Klasse I + II + III<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nennbetriebsspannung<\/td>\n<td height=\"32\">Un<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120 V\/240 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230 V\/400 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">250 V\/440 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. Dauerbetrieb mit Wechselstrom Stromspannung<\/td>\n<td height=\"32\">Uc (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">150 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">275 V\/255 V (50\/60 Hz)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">320 V\/255 V (50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Blitzsto\u00dfstrom (10\/350\u03bcs)<\/td>\n<td height=\"32\">Iimp (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Gesamtentladestrom (10\/350 \u03bcs)<\/td>\n<td height=\"32\">Insgesamt<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Nennentladestrom (8\/20\u03bcs)<\/td>\n<td height=\"32\">In (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25kA\/100kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. Entladestrom (8\/20\u03bcs)<\/td>\n<td height=\"32\">Imax (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120kA\/200kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120kA\/200kA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">120kA\/200kA<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Menge der elektrischen Ladung (L-N, N-PE)<\/td>\n<td height=\"32\">Q<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5 As, 50 As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5 As, 50 As<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">12,5 As, 50 As<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Spezifische Energie (L-N, N-PE)<\/td>\n<td height=\"32\">W\/R<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">156 kJ\/\u03a9, 2500 kJ\/\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Spannungsschutzniveau<\/td>\n<td height=\"32\">Oben (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22640,8kV\/\u22641,5kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV\/\u22641,5 kV<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u22641,3 kV\/\u22641,5 kV<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Kurzschlussstromfestigkeit AC.<\/td>\n<td height=\"32\">Isccr (L-N\/N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA Effektivwert\/100 A Effektivwert<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA Effektivwert\/100 A Effektivwert<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">25 kA Effektivwert\/100 A Effektivwert<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Max. Backup-Sicherung<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">200A gG<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tempor\u00e4re TOV-\u00dcberspannungsfestigkeit<\/td>\n<td height=\"32\">UT(L-N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">180V\/5Sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">335V\/5Sek.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">400V\/5Sek.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Vor\u00fcbergehender TOV-sicherer \u00dcberspannungsfehler<\/td>\n<td height=\"32\">UT(L-N)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">230V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">440V\/120min.<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">520V\/120min.<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Tempor\u00e4re TOV-\u00dcberspannungsfestigkeit<\/td>\n<td height=\"32\">UT(N-PE)<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">1200V\/200ms<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Leckstrom<\/td>\n<td height=\"32\">Ipe<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Keiner<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Keiner<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">Keiner<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Ansprechzeit<\/td>\n<td height=\"32\">tA<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">\u226425ns\/\u2264100ns<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Betriebstemperaturbereich<\/td>\n<td height=\"32\">Di<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">-40\u2103-80\u2103<\/td>\n<\/tr>\n<tr>\n<td>Betriebszustands-\/Fehleranzeige<\/td>\n<td><\/td>\n<td style=\"text-align: center;\">gr\u00fcn\/rot<\/td>\n<td style=\"text-align: center;\">gr\u00fcn\/rot<\/td>\n<td style=\"text-align: center;\">gr\u00fcn\/rot<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Querschnittsfl\u00e4che (Min.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">4mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Querschnittsfl\u00e4che (Max.)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">35mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Zur Montage<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">35-mm-DIN-Schiene<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Geh\u00e4usematerial<\/td>\n<td height=\"32\"><\/td>\n<td colspan=\"3\" align=\"center\" valign=\"middle\" height=\"32\">Thermoplast UL94-V0<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Schutzart<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">IP20<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Bestellcode<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17208<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18163<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17221<\/td>\n<\/tr>\n<tr>\n<td height=\"32\">Bestellcode (mit Fernsignalisierung)<\/td>\n<td height=\"32\"><\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17209<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B18164<\/td>\n<td align=\"center\" valign=\"middle\" height=\"32\">B17222<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Merkmale:<\/strong><\/p>\n<p>Die \u00dcberspannungsableiter BR-25M erf\u00fcllen die Anforderungsklasse Klasse I und Klasse II gem\u00e4\u00df IEC 61643-11.<\/p>\n<p>Beschriftete Anschl\u00fcsse.<\/p>\n<p>Elektrische \u00dcberspannungsschutzger\u00e4te funktionieren, indem sie die zus\u00e4tzliche Energie in der elektrischen \u00dcberspannung vom Hauptstromkreis wegleiten, normalerweise zur \u201cErde\u201d.<\/p>\n<p>\u00dcberspannungsschutzger\u00e4te (SPD), die an der Hauptverteilung angeschlossen sind, \u00fcberwachen st\u00e4ndig die Versorgungsspannung.<\/p>\n<div>\n<p><strong>Anwendung:<\/strong><\/p>\n<p>Diese Ger\u00e4te sch\u00fctzen Niederspannungs-Verbraucheranlagen vor \u00dcberspannung.<\/p>\n<div>Wird in Klasse I + Klasse II (Klasse B + C) f\u00fcr TT- und TN-S-Stromversorgungssysteme eingesetzt.<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1614\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe.jpg\" alt=\"\" width=\"1799\" height=\"451\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe.jpg 1799w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe-300x75.jpg 300w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe-1024x257.jpg 1024w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe-768x193.jpg 768w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-\u539f\u7406\u56fe-1536x385.jpg 1536w\" sizes=\"auto, (max-width: 1799px) 100vw, 1799px\" \/><\/div>\n<div><\/div>\n<\/div>","protected":false},"parent":0,"menu_order":77,"template":"","meta":{"_acf_changed":false},"product_category":[20],"class_list":["post-920","product","type-product","status-publish","hentry","product_category-type-1-lightning-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/product\/920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media?parent=920"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/product_category?post=920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}