{"id":848,"date":"2023-12-18T15:16:59","date_gmt":"2023-12-18T07:16:59","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=848"},"modified":"2024-09-05T16:39:56","modified_gmt":"2024-09-05T08:39:56","slug":"protection-measures-of-inductive-lightning-in-spc-exchange","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/de\/blog\/protection-measures-of-inductive-lightning-in-spc-exchange\/","title":{"rendered":"Schutzma\u00dfnahmen vor induktivem Blitz im SPC-Austausch"},"content":{"rendered":"Power communication is an indispensable and important part of modern power system and one of the three pillars for the safe and stable operation of modern power grid. SPC Exchange is an important part of power communication network. Once a fault occurs, the loss caused is not only economical. On the other hand, what is more serious is the potential threat to the grid security. Therefore, it is particularly important to strengthen the security protection of the SPC Exchange.\r\n\r\nNow many units have installed SPC Exchange, and the main component of the SPC Exchange is the integrated circuit (IC). The IC\u2019s anti-interference ability is relatively low, and even the lightning electromagnetic pulse (LEMP) induced from the line can break down the IC components. Therefore, the SPC Exchange is prone to lightning accidents. The damaged parts are mostly relay boards, user boards, billing cards and power supply parts. Due to the high value of these motherboards, in order to reduce economic losses, some users have tried various methods to protect the switch, and even insured the switch with an insurance company, but the loss caused by the interruption of communication caused by lightning strikes is irreparable. Therefore, the lightning protection of the SPC Exchange is particularly important.\r\n\r\n<strong>Der \u00c4quipotentialanschluss des Schalters<\/strong>\r\n\r\nDer Zweck des Potenzialausgleichsanschlusses des Schalters besteht darin, die Potenzialdifferenz zwischen verschiedenen Metallkomponenten und Systemen in dem Raum zu verringern, in dem ein Blitzschutz erforderlich ist.\r\n\r\n<strong>Die Qualit\u00e4t baulicher Blitzschutzanlagen<\/strong>\r\n\r\nGem\u00e4\u00df den einschl\u00e4gigen Bestimmungen von GB50057-94 muss das Geb\u00e4ude der SPC Exchange \u00fcber Einrichtungen zur Verhinderung direkter Blitzeinschl\u00e4ge verf\u00fcgen. Wenn die H\u00f6he des Geb\u00e4udes 30 m (Blitzschutz Typ 1), 45 m (Blitzschutz Typ 2) und 60 m (Blitzschutz Typ 3) \u00fcberschreitet, sollten die gro\u00dfen Metallgegenst\u00e4nde wie Gel\u00e4nder, T\u00fcren und Fenster an der Au\u00dfenwand der oben genannten H\u00f6he an das Blitzschutzger\u00e4t angeschlossen werden. Dar\u00fcber hinaus ist der Erdungswiderstand blitzschnellSchutzeinrichtungen sollten zudem den Anforderungen einschl\u00e4giger Spezifikationen gen\u00fcgen.\r\n\r\n<strong>Die Blitzschutzzone (LPZ) innerhalb des Geb\u00e4udes<\/strong>\r\n\r\nGem\u00e4\u00df den einschl\u00e4gigen Bestimmungen von IEC1312-1 ist das Geb\u00e4ude in 4 Bereiche unterteilt: LPZOA, Objekte in diesem Bereich k\u00f6nnen direkt vom Blitz getroffen werden; LPZOB, Objekte in diesem Bereich k\u00f6nnen nicht direkt vom Blitz getroffen werden und das elektromagnetische Feld in dem Bereich wird nicht ged\u00e4mpft; LPZ1: Objekte in diesem Bereich k\u00f6nnen nicht direkt vom Blitz getroffen werden und das elektromagnetische Feld in dem Bereich kann schw\u00e4cher werden; LPZ2 ist der Anschluss-Blitzschutzbereich. Gem\u00e4\u00df dem oben genannten Zoning-Prinzip, SPCDer Austausch sollte so weit wie m\u00f6glich im LPZ2-Bereich platziert werden, um die Auswirkungen elektromagnetischer Blitzimpulse auf den Schalter zu verringern.\r\n\r\n<strong>Der Standort des SPC Exchange-Raums<\/strong>\r\n\r\nThe location of the SPC Exchange room should be determined in combination with the terrain location and other factors. For high-rise buildings, the general practice is to set the room in the space below the 4th floor and above the first floor. In humid areas, it is not advisable to set up the room on the first floor.\r\n\r\nIn modern communication systems, a well-designed lightning protection system is critical to the safe operation of equipment, not just for SPC Exchange. To ensure the secure operation of the entire communication network, you must strictly follow the principles of comprehensive lightning protection and plan lightning protection from all possible routes.","protected":false},"featured_media":849,"parent":0,"menu_order":153,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-848","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Power communication is an indispensable and important part of modern power system and one of the three pillars for the safe and stable operation of modern power grid. SPC Exchange is an important part of power communication network.","txt":"Power communication is an indispensable and important part of modern power system and one of the three pillars for the safe and stable operation of modern power grid. SPC Exchange is an important part of power communication network. Once a fault occurs, the loss caused is not only economical. On the other hand, what is more serious is the potential threat to the grid security. Therefore, it is particularly important to strengthen the security protection of the SPC Exchange.\r\n\r\nNow many units have installed SPC Exchange, and the main component of the SPC Exchange is the integrated circuit (IC). The IC\u2019s anti-interference ability is relatively low, and even the lightning electromagnetic pulse (LEMP) induced from the line can break down the IC components. Therefore, the SPC Exchange is prone to lightning accidents. The damaged parts are mostly relay boards, user boards, billing cards and power supply parts. Due to the high value of these motherboards, in order to reduce economic losses, some users have tried various methods to protect the switch, and even insured the switch with an insurance company, but the loss caused by the interruption of communication caused by lightning strikes is irreparable. Therefore, the lightning protection of the SPC Exchange is particularly important.\r\n\r\n<strong>The equipotential connection of the switch<\/strong>\r\n\r\nThe purpose of equipotential connection of the switch is to reduce the potential difference between various metal components and systems in the space where lightning protection is required.\r\n\r\n<strong>The quality of building lightning protection facilities<\/strong>\r\n\r\nAccording to the relevant provisions of GB50057-94, the building of SPC Exchange must have facilities for preventing direct lightning strikes. When the height of the building exceeds 30m (type 1 lightning protection), 45m (type 2 lightning protection) and 60m (type 3 lightning protection), the large metal objects such as railings, doors and windows on the outer wall of the above height should be connected to the lightning protection device. In addition, the grounding resistance of lightning protection facilities should also meet the requirements of relevant specifications.\r\n\r\n<strong>The lightning protection zone (LPZ) inside the building<\/strong>\r\n\r\nAccording to the relevant provisions of IEC1312-1, the building is divided into 4 areas: LPZOA, objects in this area may be directly struck by lightning; LPZOB, objects in this area cannot be directly struck by lightning, and the electromagnetic field in the area is not attenuated; LPZ1, objects in this area cannot be directly struck by lightning, and the electromagnetic field in the area may attenuate; LPZ2 is the follow-up lightning protection area. According to the above zoning principle, SPC Exchange should be placed in the LPZ2 area as much as possible to reduce the impact of lightning electromagnetic pulse on the switch.\r\n\r\n<strong>The location of the SPC Exchange room<\/strong>\r\n\r\nThe location of the SPC Exchange room should be determined in combination with the terrain location and other factors. For high-rise buildings, the general practice is to set the room in the space below the 4th floor and above the first floor. In humid areas, it is not advisable to set up the room on the first floor.\r\n\r\nIn modern communication systems, a well-designed lightning protection system is critical to the safe operation of equipment, not just for SPC Exchange. To ensure the secure operation of the entire communication network, you must strictly follow the principles of comprehensive lightning protection and plan lightning protection from all possible routes."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog\/848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media\/849"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media?parent=848"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog_category?post=848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}