{"id":840,"date":"2023-12-18T15:04:36","date_gmt":"2023-12-18T07:04:36","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=840"},"modified":"2024-09-05T16:32:14","modified_gmt":"2024-09-05T08:32:14","slug":"standards-related-to-surge-protection-devices","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/de\/blog\/standards-related-to-surge-protection-devices\/","title":{"rendered":"Standards f\u00fcr \u00dcberspannungsschutzger\u00e4te"},"content":{"rendered":"<strong>IEC\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 11: \u00dcberspannungsschutzger\u00e4te f\u00fcr Niederspannungsnetze \u2013 Anforderungen und Pr\u00fcfverfahren<\/strong>\r\n\r\nIEC 61643-11:2011 gilt f\u00fcr Ger\u00e4te zum \u00dcberspannungsschutz gegen indirekte und direkte Auswirkungen von Blitzen oder anderen transienten \u00dcberspannungen. Diese Ger\u00e4te sind f\u00fcr den Anschluss an 50\/60 Hz Wechselstrom ausgelegt. Stromkreise und Ger\u00e4te mit einer Nennspannung von bis zu 1.000 V r.m.s. Leistungsmerkmale, Standardmethoden f\u00fcr Tests und Bewertungen werden festgelegt. Diese Ger\u00e4te enthalten mindestens eine nichtlineare Komponente und sollen \u00dcberspannungen begrenzen und Sto\u00dfstr\u00f6me ableiten. Diese erste Ausgabe von IECDie Norm 61643-11 hebt die 2005 ver\u00f6ffentlichte zweite Ausgabe der IEC 61643-1 auf und ersetzt sie. Die wesentlichen \u00c4nderungen gegen\u00fcber der zweiten Ausgabe der IEC 61643-1 sind die vollst\u00e4ndige Umstrukturierung und Verbesserung der Pr\u00fcfverfahren und Pr\u00fcfabl\u00e4ufe.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 21: \u00dcberspannungsschutzger\u00e4te f\u00fcr den Anschluss an Telekommunikations- und Signalnetze \u2013 Leistungsanforderungen und Pr\u00fcfverfahren<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 12: \u00dcberspannungsschutzger\u00e4te f\u00fcr Niederspannungsnetze \u2013 Auswahl und Anwendungsgrunds\u00e4tze<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>IEC 61643-22:2015\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 22: \u00dcberspannungsschutzger\u00e4te f\u00fcr den Anschluss an Telekommunikations- und Signalnetze \u2013 Auswahl- und Anwendungsgrunds\u00e4tze<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 31: Anforderungen und Pr\u00fcfverfahren f\u00fcr SPDs f\u00fcr Photovoltaikanlagen<\/strong>\r\n\r\nIEC 61643-31:2018 gilt f\u00fcr \u00dcberspannungsschutzger\u00e4te (SPDs), die f\u00fcr den \u00dcberspannungsschutz gegen indirekte und direkte Auswirkungen von Blitzen oder anderen transienten \u00dcberspannungen vorgesehen sind. Diese Ger\u00e4te sind f\u00fcr den Anschluss an die Gleichstromseite von Photovoltaikanlagen mit einer Nennspannung von bis zu 1.500 V Gleichstrom konzipiert. Diese Ger\u00e4te enthalten mindestens eine nichtlineare Komponente und sollen \u00dcberspannungen begrenzen und Sto\u00dfstr\u00f6me ableiten. Leistungsmerkmale, Sicherheitsanforderungen, Standardmethoden zum Testen undBewertungen werden erstellt. SPDs, die dieser Norm entsprechen, sind ausschlie\u00dflich f\u00fcr den Einbau auf der DC-Seite von Photovoltaikgeneratoren und der DC-Seite von Wechselrichtern vorgesehen. SPDs f\u00fcr PV-Anlagen mit Energiespeicher (z. B. Batterien, Kondensatorbatterien) sind nicht abgedeckt. SPDs mit separaten Eingangs- und Ausgangsanschl\u00fcssen, die eine bestimmte Reihenimpedanz zwischen diesen Anschl\u00fcssen aufweisen (sogenannte Zwei-Port-SPDs gem\u00e4\u00df IEC 61643-11:2011), fallen nicht darunter. SPDs, die dieser Norm entsprechen, sind darauf ausgelegtfest angeschlossen sein, wobei das Anschlie\u00dfen und Trennen fester SPDs nur mit einem Werkzeug erfolgen kann. Diese Norm gilt nicht f\u00fcr tragbare SPDs.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Niederspannungs-\u00dcberspannungsschutzger\u00e4te \u2013 Teil 32: \u00dcberspannungsschutzger\u00e4te f\u00fcr den Gleichstromanschluss Seite von Photovoltaikanlagen \u2013 Auswahl- und Anwendungsgrunds\u00e4tze<\/strong>\r\n\r\nIEC 61643-32:2017 beschreibt die Grunds\u00e4tze f\u00fcr die Auswahl, Installation und Koordination von SPDs, die f\u00fcr den Einsatz in Photovoltaiksystemen (PV) bis 1.500 V DC und f\u00fcr die AC-Seite des PV-Systems mit Nennspannungen bis 1.000 V rms 50\/60 Hz vorgesehen sind. Die Photovoltaikanlage erstreckt sich von einem PV-Array oder einem Satz miteinander verbundener PV-Module \u00fcber die dazugeh\u00f6rige Verkabelung und Schutzvorrichtungen sowie den Wechselrichter bis zum Anschlusspunkt im Verteiler oder am Einspeisepunkt. Dieser Teil von IEC 61643ber\u00fccksichtigt SPDs, die an verschiedenen Standorten und in verschiedenen Arten von PV-Systemen verwendet werden: PV-Systeme, die sich auf dem Dach eines Geb\u00e4udes befinden. Auf dem Boden befindliche PV-Anlagen wie Freilandkraftwerke zeichnen sich durch Mehrfacherdung und ein vermaschtes Erdungssystem aus. Der Begriff PV-Anlage wird f\u00fcr beide Arten von PV-Anlagen verwendet. Der Begriff PV-Kraftwerk wird nur f\u00fcr ausgedehnte, auf dem Boden befindliche Freifl\u00e4chen-Mehrleiteranlagen verwendet. F\u00fcr PV-Anlagen einschlie\u00dflich Batterien gelten zus\u00e4tzliche Anforderungenkann notwendig sein.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Redline-Version<\/strong>\r\n<strong>Komponenten des Blitzschutzsystems (LPSC) \u2013 Teil 1: Anforderungen an Anschlusskomponenten<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components.","protected":false},"featured_media":841,"parent":0,"menu_order":157,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-840","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods","txt":"<strong>IEC\/EN 61643-11:2011\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices\u2013Part11: Surge protective devices connected to low-voltage power systems\u2013Requirements and test methods<\/strong>\r\n\r\nIEC 61643-11:2011 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50\/60 Hz a.c. power circuits, and equipment rated up to 1 000 V r.m.s. Performance characteristics, standard methods for testing and ratings are established. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents. This first edition of IEC 61643-11 cancels and replaces the second edition of IEC 61643-1 published in 2005. The main changes with respect of the second edition of IEC 61643-1 are the complete restructuring and improvement of the test procedures and test sequences.\r\n\r\n<strong>IEC 61643-21:2000\/AMD2:2012\u00a0<\/strong>\r\n<strong>Low voltage surge protective devices \u2013 Part 21: Surge protective devices connected to telecommunications and signalling networks \u2013 Performance requirements and testing methods<\/strong>\r\n\r\n<strong>IEC 61643-12:2020\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 12: Surge protective devices connected to low-voltage power systems \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-12:2020 describes the principles for the selection, operation, location and coordination of SPDs to be connected to 50\/60 Hz AC power circuits, and equipment rated up to 1 000 V RMS. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents.\r\nNOTE 1 Additional requirements for special applications are also applicable, If required.\r\nNOTE 2 IEC 60364 and IEC 62305-4 are also applicable.\r\nNOTE 3 This standard deal only with SPDs and not with surge protection components\r\n\r\n<strong>IEC 61643-22:2015\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 22: Surge protective devices connected to telecommunications and signalling networks \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-22:2015 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs). This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:\r\n\u2013 Update the use of multiservice SPDs (Article 8);\r\n\u2013 Comparison between SPD classification of IEC 61643-11 and IEC 61643-21 (7.3.3);\r\n\u2013 Consideration of new transmission systems as PoE (Annex F);\r\n\u2013 EMC requirements of SPDs (Annex G);\r\n\u2013 Maintenance cycles of SPDs (Annex I). Keywords: SPD, surge protective devices\r\n\r\n<strong>IEC 61643-31:2018\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 31: Requirements and test methods for SPDs for photovoltaic installations<\/strong>\r\n\r\nIEC 61643-31:2018 is applicable to Surge Protective Devices (SPDs), intended for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are designed to be connected to the DC side of photovoltaic installations rated up to 1 500 V DC. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents. Performance characteristics, safety requirements, standard methods for testing and ratings are established.\u00a0 SPDs complying with this standard are exclusively dedicated to be installed on the DC side of photovoltaic generators and the DC side of inverters. SPDs for PV systems with energy storage (e.g. batteries, capacitor banks) are not covered. SPDs with separate input and output terminals that contain specific series impedance between these terminal(s) (so called two-port SPDs according to IEC 61643-11:2011) are not covered. SPDs compliant with this standard are designed to be permanently connected where connection and disconnection of fixed SPDs can only be done using a tool. This standard does not apply to portable SPDs.\r\n\r\n<strong>IEC 61643-32:2017\u00a0<\/strong>\r\n<strong>Low-voltage surge protective devices \u2013 Part 32: Surge protective devices connected to the d.c. side of photovoltaic installations \u2013 Selection and application principles<\/strong>\r\n\r\nIEC 61643-32:2017 describes the principles for selection, installation and coordination of SPDs intended for use in Photovoltaic (PV) systems up to 1 500 V DC and for the AC side of the PV system rated up to 1 000 V rms 50\/60 Hz. The photovoltaic installation extends from a PV array or a set of interconnected PV-modules to include the associated cabling and protective devices and the inverter up to the connection point in the distribution board or the utility supply point. This part of IEC 61643 considers SPDs used in different locations and in different kinds of PV systems:PV systems located on the top of a building. PV systems located on the ground like free field power plants characterized by multiple earthing and a meshed earthing system. The term PV installation is used to refer to both kinds of PV systems. The term PV power plant is only used for extended free-field multi-earthed power systems located on the ground. For PV installations including batteries additional requirements may be necessary.\r\n\r\n<strong>IEC 62561-1:2017 RLV\u00a0<\/strong>\r\n<strong>Redline version<\/strong>\r\n<strong>Lightning protection system components (LPSC) \u2013 Part 1: Requirements for connection components<\/strong>\r\n\r\nIEC 62561-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.\r\n\r\nIEC 62561-1:2017 specifies the requirements and tests for metallic connection components that form part of a lightning protection system (LPS). Typically, these can be connectors, clamps, bonding and bridging components, expansion pieces and test joints.\r\nFor the purposes of this document the following connection types are considered as connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing or bolting. Testing of components for an explosive atmosphere is not covered by this document.\r\nThis second edition cancels and replaces the first edition, published in 2012. This edition constitutes a technical revision.\r\nThis edition includes the following significant technical changes with respect to the previous edition:\r\na. classification of connection components in permanent and non-permanent connection;\r\nb. requirements and corresponding tests for permanent connection components such as exothermic, brazing, welding, crimping, seaming;\r\nc. flow chart of tests for connection components."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog\/840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media\/841"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media?parent=840"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog_category?post=840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}