{"id":784,"date":"2023-12-19T15:48:41","date_gmt":"2023-12-19T07:48:41","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=784"},"modified":"2025-05-26T14:38:24","modified_gmt":"2025-05-26T06:38:24","slug":"classification-of-spds","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/de\/blog\/classification-of-spds\/","title":{"rendered":"Klassifizierung von SPDs"},"content":{"rendered":"Ein \u00dcberspannungsschutzger\u00e4t (SPD) sch\u00fctzt elektrische Systeme und Ger\u00e4te vor \u00dcberspannungsereignissen, indem es transiente Spannungen begrenzt und \u00dcberspannungen ableitet.\r\n<h2><strong>Die wichtigen technischen Merkmale von SPD:<\/strong><\/h2>\r\n<ul data-start=\"517\" data-end=\"826\">\r\n \t<li data-start=\"517\" data-end=\"566\">\r\n<p data-start=\"519\" data-end=\"566\">Maximale Dauerbetriebsspannung (Uc)<\/p>\r\n<\/li>\r\n \t<li data-start=\"567\" data-end=\"607\">\r\n<p data-start=\"569\" data-end=\"607\">Blitzsto\u00dfstrom (Iimp)<\/p>\r\n<\/li>\r\n \t<li data-start=\"608\" data-end=\"646\">\r\n<p data-start=\"610\" data-end=\"646\">Nennentladestrom (I)<\/p>\r\n<\/li>\r\n \t<li data-start=\"647\" data-end=\"684\">\r\n<p data-start=\"649\" data-end=\"684\">Spannungsschutzpegel (Up)<\/p>\r\n<\/li>\r\n \t<li data-start=\"685\" data-end=\"735\">\r\n<p data-start=\"687\" data-end=\"735\">Kurzschlussfestigkeit (Isccr)<\/p>\r\n<\/li>\r\n \t<li data-start=\"736\" data-end=\"792\">\r\n<p data-start=\"738\" data-end=\"792\">Freilaufunterbrechungsf\u00e4higkeit bei Uc (Ifi)<\/p>\r\n<\/li>\r\n \t<li data-start=\"793\" data-end=\"826\">\r\n<p data-start=\"795\" data-end=\"826\">Transiente \u00dcberspannung (TOV)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"828\" data-end=\"1016\">Diese Parameter bestimmen die Leistung des SPD unter verschiedenen Fehlerbedingungen und m\u00fcssen sorgf\u00e4ltig an die Spannung des Systems, den Installationsort und die erwartete \u00dcberspannungsumgebung angepasst werden.<\/p>\r\n\r\n<h2><strong>SPD-Kategorien oder -Typen<\/strong><\/h2>\r\n<p data-start=\"1055\" data-end=\"1156\">SPDs werden im Allgemeinen auf der Grundlage interner Arbeitsprinzipien und Standardtestmethoden klassifiziert.<\/p>\r\n\r\n<h3 data-start=\"1158\" data-end=\"1187\"><strong data-start=\"1162\" data-end=\"1187\">Nach Komponentenverhalten<\/strong><\/h3>\r\n<p data-start=\"1189\" data-end=\"1220\">Die zwei Haupttypen von SPDs sind:<\/p>\r\n\r\n<ul data-start=\"1222\" data-end=\"1292\">\r\n \t<li data-start=\"1222\" data-end=\"1257\">\r\n<p data-start=\"1224\" data-end=\"1257\">Spannungsbegrenzende Komponenten<\/p>\r\n<\/li>\r\n \t<li data-start=\"1258\" data-end=\"1292\">\r\n<p data-start=\"1260\" data-end=\"1292\">Spannungsschaltkomponenten<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1294\" data-end=\"1417\">Die meisten modernen SPDs enthalten beide Komponententypen, um die Vorteile beider zu kombinieren und ihre jeweiligen Schw\u00e4chen zu verringern.<\/p>\r\n<p data-start=\"1419\" data-end=\"1461\">Zu den spannungsbegrenzenden Komponenten geh\u00f6ren:<\/p>\r\n\r\n<ul data-start=\"1462\" data-end=\"1539\">\r\n \t<li data-start=\"1462\" data-end=\"1494\">\r\n<p data-start=\"1464\" data-end=\"1494\">Metalloxid-Varistoren (MOVs)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1495\" data-end=\"1539\">\r\n<p data-start=\"1497\" data-end=\"1539\">Transientenspannungsunterdr\u00fcckungsdioden (TVS).<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1541\" data-end=\"1584\">Zu den Spannungsschaltkomponenten geh\u00f6ren:<\/p>\r\n\r\n<ul data-start=\"1585\" data-end=\"1628\">\r\n \t<li data-start=\"1585\" data-end=\"1615\">\r\n<p data-start=\"1587\" data-end=\"1615\">Gasentladungsr\u00f6hren (GDTs)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1616\" data-end=\"1628\">\r\n<p data-start=\"1618\" data-end=\"1628\">Funkenstrecken<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1630\" data-end=\"1725\">Diese Komponenten unterscheiden sich in der Reaktionsgeschwindigkeit, der Energieaufnahmekapazit\u00e4t und den Alterungseigenschaften.<\/p>\r\n<img class=\"size-full wp-image-17918 aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26.png\" sizes=\"(max-width: 570px) 100vw, 570px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26.png 570w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26-400x247.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26-150x93.png 150w\" alt=\"\" width=\"570\" height=\"352\" \/>\r\n<h2 data-start=\"1732\" data-end=\"1770\"><strong data-start=\"1735\" data-end=\"1770\">SPD-Klassifizierung nach Standards<\/strong><\/h2>\r\n<p data-start=\"1772\" data-end=\"1941\">Gem\u00e4\u00df ANSI\/IEEE C62.41, IEC 61643-11 und VDE-Klassifizierung gibt es drei Standard-SPD-Typen, basierend auf ihrer getesteten Wellenform und Anwendungsebene.<\/p>\r\n\r\n<h3 data-start=\"1943\" data-end=\"1961\"><strong data-start=\"1947\" data-end=\"1961\">Typ 1 SPD<\/strong><\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/de\/product\/brpv3-1000-12-5vg-1000v-12-5ka-type-12-pv-class-i-class-ii-spd\/\" rel=\"attachment wp-att-2104\"><img class=\"alignnone wp-image-2104\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/PV-Power-Surge-Protection-1024x1024.webp\" alt=\"\u00dcberspannungsschutzger\u00e4t Typ 1\" width=\"742\" height=\"742\" \/><\/a>\r\n<ul data-start=\"1963\" data-end=\"2210\">\r\n \t<li data-start=\"1963\" data-end=\"2035\">\r\n<p data-start=\"1965\" data-end=\"2035\">Getestet mit Impulsentladungsstrom Iimp (typischerweise 10\/350 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2036\" data-end=\"2085\">\r\n<p data-start=\"2038\" data-end=\"2085\">Auch mit 8\/20 \u00b5s Stromimpulsen getestet<\/p>\r\n<\/li>\r\n \t<li data-start=\"2086\" data-end=\"2139\">\r\n<p data-start=\"2088\" data-end=\"2139\">Konzipiert f\u00fcr die Installation am Serviceeingang<\/p>\r\n<\/li>\r\n \t<li data-start=\"2140\" data-end=\"2210\">\r\n<p data-start=\"2142\" data-end=\"2210\">Sch\u00fctzt vor direktem Blitzstrom und energiereichen \u00dcberspannungen<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"2212\" data-end=\"2230\"><strong data-start=\"2216\" data-end=\"2230\">Typ 2 SPD<\/strong><\/h3>\r\n<ul data-start=\"2232\" data-end=\"2651\">\r\n \t<li data-start=\"2232\" data-end=\"2290\">\r\n<p data-start=\"2234\" data-end=\"2290\">Getestet mit Nennentladestrom in (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2291\" data-end=\"2362\">\r\n<p data-start=\"2293\" data-end=\"2362\">Optional getestet mit maximalem Entladestrom Imax (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2363\" data-end=\"2429\">\r\n<p data-start=\"2365\" data-end=\"2429\">Hinweis: Imax wird nicht als Grundlage f\u00fcr die SPD-Auswahl empfohlen<\/p>\r\n<\/li>\r\n \t<li data-start=\"2430\" data-end=\"2525\">\r\n<p data-start=\"2432\" data-end=\"2525\">F\u00fcr SPDs mit spannungsschaltenden Bauteilen, auch gepr\u00fcft mit 1,2\/50 \u00b5s Spannungsimpulsen.<\/p>\r\n<\/li>\r\n \t<li data-start=\"2526\" data-end=\"2586\">\r\n<p data-start=\"2528\" data-end=\"2586\">Wird an Unterverteilern oder Ger\u00e4teeing\u00e4ngen installiert<\/p>\r\n<\/li>\r\n \t<li data-start=\"2587\" data-end=\"2651\">\r\n<p data-start=\"2589\" data-end=\"2651\">Sch\u00fctzt vor Schalt\u00fcberspannungen und indirektem Blitzschlag<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"2653\" data-end=\"2671\"><strong data-start=\"2657\" data-end=\"2671\">Typ 3 SPD<\/strong><\/h3>\r\n<ul data-start=\"2673\" data-end=\"2913\">\r\n \t<li data-start=\"2673\" data-end=\"2843\">\r\n<p data-start=\"2675\" data-end=\"2722\">Getestet mit einem Kombinationswellengenerator:<\/p>\r\n\r\n<ul data-start=\"2725\" data-end=\"2843\">\r\n \t<li data-start=\"2725\" data-end=\"2765\">\r\n<p data-start=\"2727\" data-end=\"2765\">Leerlaufspannung Uoc (1,2\/50 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2768\" data-end=\"2807\">\r\n<p data-start=\"2770\" data-end=\"2807\">Kurzschlussstrom Icw (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2810\" data-end=\"2843\">\r\n<p data-start=\"2812\" data-end=\"2843\">Nominale Ausgangsimpedanz: 2 \u03a9<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"2844\" data-end=\"2913\">\r\n<p data-start=\"2846\" data-end=\"2913\">F\u00fcr optimalen Schutz in der N\u00e4he empfindlicher Endger\u00e4te installiert<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h2 data-start=\"2920\" data-end=\"2960\"><strong data-start=\"2923\" data-end=\"2960\">SPD-Anwendungen in Energiesystemen<\/strong><\/h2>\r\n<p data-start=\"2962\" data-end=\"3069\">SPDs werden in einer Vielzahl von AC- und DC-Systemen eingesetzt, f\u00fcr die jeweils spezifische Design- und Auswahlanforderungen gelten.<\/p>\r\n\r\n<h3 data-start=\"3071\" data-end=\"3110\"><strong data-start=\"3075\" data-end=\"3110\">1. Anwendungen von Wechselstromsystemen<\/strong><\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/de\/classification-of-spds\/attachment\/ac-power-surge-protection-2\/\" rel=\"attachment wp-att-2103\"><img class=\"alignnone wp-image-2103\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/AC-Power-Surge-Protection-1024x1024.webp\" alt=\"Wechselstrom-\u00dcberspannungsschutzger\u00e4t\" width=\"868\" height=\"868\" \/><\/a>\r\n<p data-start=\"3112\" data-end=\"3303\">In Wechselstromverteilungssystemen werden SPDs haupts\u00e4chlich zum Schutz von Ger\u00e4ten und Stromnetzen vor transienten \u00dcberspannungen eingesetzt, die durch Blitzeinschl\u00e4ge, Netzumschaltungen und Fehlerbeseitigungsereignisse verursacht werden.<\/p>\r\n\r\n<ul data-start=\"3305\" data-end=\"3453\">\r\n \t<li data-start=\"3305\" data-end=\"3392\">\r\n<p data-start=\"3307\" data-end=\"3392\"><strong data-start=\"3307\" data-end=\"3322\">SPDs vom Typ 1<\/strong>: Wird an Hauptverteilern installiert, um \u00dcberspannungen mit hoher Energie zu bew\u00e4ltigen<\/p>\r\n<\/li>\r\n \t<li data-start=\"3393\" data-end=\"3453\">\r\n<p data-start=\"3395\" data-end=\"3453\"><strong data-start=\"3395\" data-end=\"3410\">SPDs vom Typ 2<\/strong>: Zum lokalen Schutz stromabw\u00e4rts installiert<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3455\" data-end=\"3591\">SPDs f\u00fcr Wechselstrom m\u00fcssen der Nennspannung und Uc des Systems entsprechen und gleichzeitig eine ausreichende Kurzschlussfestigkeit (Isccr) bieten.<\/p>\r\n<p data-start=\"3593\" data-end=\"3629\">Zu den typischen internen Komponenten geh\u00f6ren:<\/p>\r\n\r\n<ul data-start=\"3630\" data-end=\"3736\">\r\n \t<li data-start=\"3630\" data-end=\"3677\">\r\n<p data-start=\"3632\" data-end=\"3677\">MOVs f\u00fcr schnelle Reaktion und Spannungsbegrenzung<\/p>\r\n<\/li>\r\n \t<li data-start=\"3678\" data-end=\"3736\">\r\n<p data-start=\"3680\" data-end=\"3736\">GDTs f\u00fcr die Handhabung hoher Energie und die Isolierung gegen Leckagen<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3738\" data-end=\"3801\">Die Kombination aus beidem sorgt f\u00fcr schnelle Unterdr\u00fcckung und Langlebigkeit.<\/p>\r\n\r\n<h3 data-start=\"3808\" data-end=\"3847\"><strong data-start=\"3812\" data-end=\"3847\">2. Anwendungen von Gleichstromsystemen<\/strong><\/h3>\r\n<p data-start=\"3849\" data-end=\"3868\">Gleichstromsysteme wie:<\/p>\r\n\r\n<ul data-start=\"3869\" data-end=\"3979\">\r\n \t<li data-start=\"3869\" data-end=\"3894\">\r\n<p data-start=\"3871\" data-end=\"3894\">Telekommunikations-Basisstationen<\/p>\r\n<\/li>\r\n \t<li data-start=\"3895\" data-end=\"3926\">\r\n<p data-start=\"3897\" data-end=\"3926\">Industrielle Schaltschr\u00e4nke<\/p>\r\n<\/li>\r\n \t<li data-start=\"3927\" data-end=\"3946\">\r\n<p data-start=\"3929\" data-end=\"3946\">Batteriespeicher<\/p>\r\n<\/li>\r\n \t<li data-start=\"3947\" data-end=\"3962\">\r\n<p data-start=\"3949\" data-end=\"3962\">Laden von Elektrofahrzeugen<\/p>\r\n<\/li>\r\n \t<li data-start=\"3963\" data-end=\"3979\">\r\n<p data-start=\"3965\" data-end=\"3979\">Solar-DC-Busse<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3981\" data-end=\"4095\">\u2026erfordern SPDs, die speziell f\u00fcr kontinuierliche Gleichspannung ausgelegt sind, bei denen es keinen Nulldurchgang gibt und die Lichtb\u00f6gen aushalten k\u00f6nnen.<\/p>\r\n<p data-start=\"4097\" data-end=\"4105\">DC-SPDs:<\/p>\r\n\r\n<ul data-start=\"4106\" data-end=\"4332\">\r\n \t<li data-start=\"4106\" data-end=\"4143\">\r\n<p data-start=\"4108\" data-end=\"4143\">Verwenden Sie normalerweise Hochspannungs-MOVs<\/p>\r\n<\/li>\r\n \t<li data-start=\"4144\" data-end=\"4208\">\r\n<p data-start=\"4146\" data-end=\"4208\">Muss eine hohe Dauergleichspannung ohne \u00dcberhitzung bew\u00e4ltigen<\/p>\r\n<\/li>\r\n \t<li data-start=\"4209\" data-end=\"4270\">\r\n<p data-start=\"4211\" data-end=\"4270\">Installiert an DC-Panels, Wechselrichtereing\u00e4ngen oder Batterieb\u00e4nken<\/p>\r\n<\/li>\r\n \t<li data-start=\"4271\" data-end=\"4332\">\r\n<p data-start=\"4273\" data-end=\"4332\">Vermeiden Sie Systemausf\u00e4lle aufgrund von \u00dcberspannungen oder Schaltger\u00e4uschen<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"4339\" data-end=\"4387\"><strong data-start=\"4343\" data-end=\"4387\">3. Anwendungen von Photovoltaik-Systemen (PV).<\/strong><\/h3>\r\n<p data-start=\"4389\" data-end=\"4540\">PV-Systeme erfordern hohe Gleichspannungen (bis zu 1500 VDC), gro\u00dfe Feldfl\u00e4chen und sind aufgrund der Dach- oder Feldmontage h\u00e4ufig Blitz\u00fcberspannungen ausgesetzt.<\/p>\r\n<p data-start=\"4542\" data-end=\"4576\">PV-spezifische SPDs m\u00fcssen Folgendes erf\u00fcllen:<\/p>\r\n\r\n<ul data-start=\"4577\" data-end=\"4615\">\r\n \t<li data-start=\"4577\" data-end=\"4597\">\r\n<p data-start=\"4579\" data-end=\"4597\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/26931\" target=\"_blank\" rel=\"nofollow noopener\"><strong data-start=\"4579\" data-end=\"4595\">IEC 61643-31<\/strong><\/a><\/p>\r\n<\/li>\r\n \t<li data-start=\"4598\" data-end=\"4615\">\r\n<p data-start=\"4600\" data-end=\"4615\"><a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/22527\/5b6a4f03275341d2bd18880b7a0877e7\/SIST-EN-50539-11-2013.pdf\" target=\"_blank\" rel=\"nofollow noopener\"><strong data-start=\"4600\" data-end=\"4615\">EN 50539-11<\/strong><\/a><\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4617\" data-end=\"4638\">Sie werden eingesetzt bei:<\/p>\r\n\r\n<ul data-start=\"4639\" data-end=\"4791\">\r\n \t<li data-start=\"4639\" data-end=\"4685\">\r\n<p data-start=\"4641\" data-end=\"4685\"><strong data-start=\"4641\" data-end=\"4652\">DC-Seite<\/strong>: Zwischen der PV-Anlage und dem Wechselrichter<\/p>\r\n<\/li>\r\n \t<li data-start=\"4686\" data-end=\"4740\">\r\n<p data-start=\"4688\" data-end=\"4740\"><strong data-start=\"4688\" data-end=\"4706\">Wechselrichtereingang<\/strong>: F\u00fcr den internen DC-Bus-Schutz<\/p>\r\n<\/li>\r\n \t<li data-start=\"4741\" data-end=\"4791\">\r\n<p data-start=\"4743\" data-end=\"4791\"><strong data-start=\"4743\" data-end=\"4754\">AC-Seite<\/strong>: Zwischen Wechselrichter und Netzschnittstelle<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4793\" data-end=\"4814\">Zu den Anforderungen geh\u00f6ren:<\/p>\r\n\r\n<ul data-start=\"4815\" data-end=\"4942\">\r\n \t<li data-start=\"4815\" data-end=\"4837\">\r\n<p data-start=\"4817\" data-end=\"4837\">Hoher MCOV (Uc)<\/p>\r\n<\/li>\r\n \t<li data-start=\"4838\" data-end=\"4871\">\r\n<p data-start=\"4840\" data-end=\"4871\">Niedrige Schutzstufe (Hoch)<\/p>\r\n<\/li>\r\n \t<li data-start=\"4872\" data-end=\"4891\">\r\n<p data-start=\"4874\" data-end=\"4891\">Lange Sto\u00dflebensdauer<\/p>\r\n<\/li>\r\n \t<li data-start=\"4892\" data-end=\"4942\">\r\n<p data-start=\"4894\" data-end=\"4942\">Witterungs- und UV-Best\u00e4ndigkeit (f\u00fcr Outdoor-DC-Boxen)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4944\" data-end=\"5038\">Gut platzierte PV-SPDs reduzieren die Kosten f\u00fcr den Austausch von Ger\u00e4ten und verbessern die Systemzuverl\u00e4ssigkeit und den ROI.<\/p>\r\n\r\n<h2 data-start=\"5045\" data-end=\"5094\"><strong data-start=\"5048\" data-end=\"5094\">Iimp vs. Imax in SPD-Bewertungen verstehen<\/strong><\/h2>\r\n<h3 data-start=\"5096\" data-end=\"5136\"><strong data-start=\"5100\" data-end=\"5136\">Impulsentladestrom (Iimp)<\/strong><\/h3>\r\n<ul data-start=\"5138\" data-end=\"5403\">\r\n \t<li data-start=\"5138\" data-end=\"5174\">\r\n<p data-start=\"5140\" data-end=\"5174\">Charakteristisch f\u00fcr Typ-1-SPD<\/p>\r\n<\/li>\r\n \t<li data-start=\"5175\" data-end=\"5216\">\r\n<p data-start=\"5177\" data-end=\"5216\">Simuliert einen direkten Blitzeinschlag<\/p>\r\n<\/li>\r\n \t<li data-start=\"5217\" data-end=\"5255\">\r\n<p data-start=\"5219\" data-end=\"5255\">Getestet mit 10\/350 \u00b5s Wellenform<\/p>\r\n<\/li>\r\n \t<li data-start=\"5256\" data-end=\"5325\">\r\n<p data-start=\"5258\" data-end=\"5325\">Stellt die F\u00e4higkeit der SPD dar, einen einzelnen extremen Anstieg zu bew\u00e4ltigen<\/p>\r\n<\/li>\r\n \t<li data-start=\"5326\" data-end=\"5403\">\r\n<p data-start=\"5328\" data-end=\"5403\">Geeignet f\u00fcr Geb\u00e4udeeinf\u00fchrungspunkte oder nachgeschaltete Blitzableiter<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"5405\" data-end=\"5445\"><strong data-start=\"5409\" data-end=\"5445\">Maximaler Entladestrom (Imax)<\/strong><\/h3>\r\n<ul data-start=\"5447\" data-end=\"5717\">\r\n \t<li data-start=\"5447\" data-end=\"5483\">\r\n<p data-start=\"5449\" data-end=\"5483\">Charakteristisch f\u00fcr Typ-2-SPD<\/p>\r\n<\/li>\r\n \t<li data-start=\"5484\" data-end=\"5567\">\r\n<p data-start=\"5486\" data-end=\"5567\">Simuliert mehrere \u00dcberspannungen niedrigerer Energie durch Schaltvorg\u00e4nge oder indirekte Blitze<\/p>\r\n<\/li>\r\n \t<li data-start=\"5568\" data-end=\"5604\">\r\n<p data-start=\"5570\" data-end=\"5604\">Getestet mit 8\/20 \u00b5s Wellenform<\/p>\r\n<\/li>\r\n \t<li data-start=\"5605\" data-end=\"5643\">\r\n<p data-start=\"5607\" data-end=\"5643\">Spiegelt die langfristige \u00dcberspannungsfestigkeit wider<\/p>\r\n<\/li>\r\n \t<li data-start=\"5644\" data-end=\"5717\">\r\n<p data-start=\"5646\" data-end=\"5717\">Geeignet f\u00fcr Verteilertafeln und den Schutz auf Ger\u00e4teebene<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"5719\" data-end=\"5737\"><strong data-start=\"5722\" data-end=\"5736\">Zusammenfassend<\/strong>:<\/p>\r\n\r\n<ul data-start=\"5738\" data-end=\"5943\">\r\n \t<li data-start=\"5738\" data-end=\"5796\">\r\n<p data-start=\"5740\" data-end=\"5796\"><strong data-start=\"5740\" data-end=\"5748\">Iimp<\/strong> = H\u00f6chste Ausdauer bei seltenen, energiereichen Ereignissen<\/p>\r\n<\/li>\r\n \t<li data-start=\"5797\" data-end=\"5943\">\r\n<p data-start=\"5799\" data-end=\"5943\"><strong data-start=\"5799\" data-end=\"5807\">Imax<\/strong> = Wiederholte Ausdauer f\u00fcr h\u00e4ufige Transienten mit niedrigerer Energie<br data-start=\"5867\" data-end=\"5870\" \/>Beides ist f\u00fcr den Aufbau einer mehrstufigen SPD-Schutzstrategie von wesentlicher Bedeutung.<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h2 data-start=\"5950\" data-end=\"5967\"><strong data-start=\"5953\" data-end=\"5967\">Abschluss<\/strong><\/h2>\r\n<p data-start=\"5969\" data-end=\"6277\">\u00dcberspannungsschutzger\u00e4te sind f\u00fcr moderne Energiesysteme unerl\u00e4sslich, da sie die Sicherheit der Ger\u00e4te und die Kontinuit\u00e4t der Stromversorgung gew\u00e4hrleisten. Ihre Klassifizierung in Typ 1, 2 und 3 sowie das Verst\u00e4ndnis technischer Parameter wie Uc, Up, Iimp und Imax sind f\u00fcr die richtige Auswahl und Implementierung von entscheidender Bedeutung.<\/p>\r\n<p data-start=\"6279\" data-end=\"6457\">Ganz gleich, ob es sich um den Schutz von Wechselstromsystemen, Gleichstromautomatisierung oder Solar-PV handelt: Die Auswahl des richtigen SPD mit geeigneten Nennwerten tr\u00e4gt dazu bei, Sch\u00e4den zu reduzieren, die Betriebs- und Wartungskosten zu senken und die Systemlebensdauer zu verl\u00e4ngern.<\/p>\r\n<p data-start=\"6459\" data-end=\"6579\">Ein ausgereifter SPD-Plan ist eine kleine Investition, die Ihre gro\u00dfe Infrastruktur vor irreversiblen Sch\u00e4den sch\u00fctzt.<\/p>","protected":false},"featured_media":785,"parent":0,"menu_order":182,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-784","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"A surge protective device (SPD) is designed to protect electrical systems and equipment from surge events by limiting transient voltages and diverting surge currents.","txt":"A surge protective device (SPD) protects electrical systems and equipment from surge events by limiting transient voltages and diverting surge currents.\r\n<h2><strong>The important technical characteristics of SPD:<\/strong><\/h2>\r\n<ul data-start=\"517\" data-end=\"826\">\r\n \t<li data-start=\"517\" data-end=\"566\">\r\n<p data-start=\"519\" data-end=\"566\">Maximum continuous operating voltage (Uc)<\/p>\r\n<\/li>\r\n \t<li data-start=\"567\" data-end=\"607\">\r\n<p data-start=\"569\" data-end=\"607\">Lightning impulse current (Iimp)<\/p>\r\n<\/li>\r\n \t<li data-start=\"608\" data-end=\"646\">\r\n<p data-start=\"610\" data-end=\"646\">Nominal discharge current (I)<\/p>\r\n<\/li>\r\n \t<li data-start=\"647\" data-end=\"684\">\r\n<p data-start=\"649\" data-end=\"684\">Voltage protection level (Up)<\/p>\r\n<\/li>\r\n \t<li data-start=\"685\" data-end=\"735\">\r\n<p data-start=\"687\" data-end=\"735\">Short circuit withstand capability (Isccr)<\/p>\r\n<\/li>\r\n \t<li data-start=\"736\" data-end=\"792\">\r\n<p data-start=\"738\" data-end=\"792\">Freewheeling interruption capability at Uc (Ifi)<\/p>\r\n<\/li>\r\n \t<li data-start=\"793\" data-end=\"826\">\r\n<p data-start=\"795\" data-end=\"826\">Transient overvoltage (TOV)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"828\" data-end=\"1016\">These parameters determine the SPD\u2019s performance under different fault conditions and must be matched carefully to the system\u2019s voltage, installation point, and expected surge environment.<\/p>\r\n\r\n<h2><strong>SPD Categories or Types<\/strong><\/h2>\r\n<p data-start=\"1055\" data-end=\"1156\">SPDs are generally classified based on internal working principles and standard testing methods.<\/p>\r\n\r\n<h3 data-start=\"1158\" data-end=\"1187\"><strong data-start=\"1162\" data-end=\"1187\">By Component Behavior<\/strong><\/h3>\r\n<p data-start=\"1189\" data-end=\"1220\">The two main types of SPDs are:<\/p>\r\n\r\n<ul data-start=\"1222\" data-end=\"1292\">\r\n \t<li data-start=\"1222\" data-end=\"1257\">\r\n<p data-start=\"1224\" data-end=\"1257\">Voltage limiting components<\/p>\r\n<\/li>\r\n \t<li data-start=\"1258\" data-end=\"1292\">\r\n<p data-start=\"1260\" data-end=\"1292\">Voltage switching components<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1294\" data-end=\"1417\">Most modern SPDs incorporate both component types to combine the advantages of each and reduce their respective weaknesses.<\/p>\r\n<p data-start=\"1419\" data-end=\"1461\">Voltage limiting components include:<\/p>\r\n\r\n<ul data-start=\"1462\" data-end=\"1539\">\r\n \t<li data-start=\"1462\" data-end=\"1494\">\r\n<p data-start=\"1464\" data-end=\"1494\">Metal Oxide Varistors (MOVs)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1495\" data-end=\"1539\">\r\n<p data-start=\"1497\" data-end=\"1539\">Transient Voltage Suppression (TVS) diodes<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1541\" data-end=\"1584\">Voltage switching components include:<\/p>\r\n\r\n<ul data-start=\"1585\" data-end=\"1628\">\r\n \t<li data-start=\"1585\" data-end=\"1615\">\r\n<p data-start=\"1587\" data-end=\"1615\">Gas Discharge Tubes (GDTs)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1616\" data-end=\"1628\">\r\n<p data-start=\"1618\" data-end=\"1628\">Spark gaps<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"1630\" data-end=\"1725\">These components differ in response speed, energy-handling capacity, and aging characteristics.<\/p>\r\n<img class=\"size-full wp-image-17918 aligncenter\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26.png\" sizes=\"(max-width: 570px) 100vw, 570px\" srcset=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26.png 570w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26-400x247.png 400w, https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/26-150x93.png 150w\" alt=\"\" width=\"570\" height=\"352\" \/>\r\n<h2 data-start=\"1732\" data-end=\"1770\"><strong data-start=\"1735\" data-end=\"1770\">SPD Classification by Standards<\/strong><\/h2>\r\n<p data-start=\"1772\" data-end=\"1941\">According to ANSI\/IEEE C62.41, IEC 61643-11, and VDE Classification, there are three standard SPD types based on their tested waveform and application level.<\/p>\r\n\r\n<h3 data-start=\"1943\" data-end=\"1961\"><strong data-start=\"1947\" data-end=\"1961\">Type 1 SPD<\/strong><\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/brpv3-1000-12-5vg-1000v-12-5ka-type-12-pv-class-i-class-ii-spd\/\" rel=\"attachment wp-att-2104\"><img class=\"alignnone wp-image-2104\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/PV-Power-Surge-Protection-1024x1024.webp\" alt=\"Type 1 Surge Protection Device\" width=\"742\" height=\"742\" \/><\/a>\r\n<ul data-start=\"1963\" data-end=\"2210\">\r\n \t<li data-start=\"1963\" data-end=\"2035\">\r\n<p data-start=\"1965\" data-end=\"2035\">Tested with impulse discharge current Iimp (typically 10\/350 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2036\" data-end=\"2085\">\r\n<p data-start=\"2038\" data-end=\"2085\">Also tested with 8\/20 \u00b5s current impulses<\/p>\r\n<\/li>\r\n \t<li data-start=\"2086\" data-end=\"2139\">\r\n<p data-start=\"2088\" data-end=\"2139\">Designed for installation at the service entrance<\/p>\r\n<\/li>\r\n \t<li data-start=\"2140\" data-end=\"2210\">\r\n<p data-start=\"2142\" data-end=\"2210\">Protects against direct lightning current and high-energy surges<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"2212\" data-end=\"2230\"><strong data-start=\"2216\" data-end=\"2230\">Type 2 SPD<\/strong><\/h3>\r\n<ul data-start=\"2232\" data-end=\"2651\">\r\n \t<li data-start=\"2232\" data-end=\"2290\">\r\n<p data-start=\"2234\" data-end=\"2290\">Tested with nominal discharge current in (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2291\" data-end=\"2362\">\r\n<p data-start=\"2293\" data-end=\"2362\">Optionally tested with maximum discharge current Imax (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2363\" data-end=\"2429\">\r\n<p data-start=\"2365\" data-end=\"2429\">Note: Imax is not recommended as a basis for SPD selection<\/p>\r\n<\/li>\r\n \t<li data-start=\"2430\" data-end=\"2525\">\r\n<p data-start=\"2432\" data-end=\"2525\">For SPDs with voltage switching components, also tested with 1.2\/50 \u00b5s voltage impulses.<\/p>\r\n<\/li>\r\n \t<li data-start=\"2526\" data-end=\"2586\">\r\n<p data-start=\"2528\" data-end=\"2586\">Installed at sub-distribution boards or equipment inputs<\/p>\r\n<\/li>\r\n \t<li data-start=\"2587\" data-end=\"2651\">\r\n<p data-start=\"2589\" data-end=\"2651\">Protects against switching surges and indirect lightning<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"2653\" data-end=\"2671\"><strong data-start=\"2657\" data-end=\"2671\">Type 3 SPD<\/strong><\/h3>\r\n<ul data-start=\"2673\" data-end=\"2913\">\r\n \t<li data-start=\"2673\" data-end=\"2843\">\r\n<p data-start=\"2675\" data-end=\"2722\">Tested with a combination wave generator:<\/p>\r\n\r\n<ul data-start=\"2725\" data-end=\"2843\">\r\n \t<li data-start=\"2725\" data-end=\"2765\">\r\n<p data-start=\"2727\" data-end=\"2765\">Open-circuit voltage Uoc (1.2\/50 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2768\" data-end=\"2807\">\r\n<p data-start=\"2770\" data-end=\"2807\">Short-circuit current Icw (8\/20 \u00b5s)<\/p>\r\n<\/li>\r\n \t<li data-start=\"2810\" data-end=\"2843\">\r\n<p data-start=\"2812\" data-end=\"2843\">Nominal output impedance: 2 \u03a9<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"2844\" data-end=\"2913\">\r\n<p data-start=\"2846\" data-end=\"2913\">Installed near sensitive terminal equipment for fine protection<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h2 data-start=\"2920\" data-end=\"2960\"><strong data-start=\"2923\" data-end=\"2960\">SPD Applications in Power Systems<\/strong><\/h2>\r\n<p data-start=\"2962\" data-end=\"3069\">SPDs are used in a wide range of AC and DC systems, each having specific design and selection requirements.<\/p>\r\n\r\n<h3 data-start=\"3071\" data-end=\"3110\"><strong data-start=\"3075\" data-end=\"3110\">1. AC Power System Applications<\/strong><\/h3>\r\n<a href=\"https:\/\/www.britecelectric.com\/classification-of-spds\/attachment\/ac-power-surge-protection-2\/\" rel=\"attachment wp-att-2103\"><img class=\"alignnone wp-image-2103\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/12\/AC-Power-Surge-Protection-1024x1024.webp\" alt=\"AC Power Surge Protection Device\" width=\"868\" height=\"868\" \/><\/a>\r\n<p data-start=\"3112\" data-end=\"3303\">In AC distribution systems, SPDs are mainly used to protect equipment and power networks from transient overvoltages caused by lightning strikes, utility switching, and fault-clearing events.<\/p>\r\n\r\n<ul data-start=\"3305\" data-end=\"3453\">\r\n \t<li data-start=\"3305\" data-end=\"3392\">\r\n<p data-start=\"3307\" data-end=\"3392\"><strong data-start=\"3307\" data-end=\"3322\">Type 1 SPDs<\/strong>: Installed at main distribution boards to handle high-energy surges<\/p>\r\n<\/li>\r\n \t<li data-start=\"3393\" data-end=\"3453\">\r\n<p data-start=\"3395\" data-end=\"3453\"><strong data-start=\"3395\" data-end=\"3410\">Type 2 SPDs<\/strong>: Installed downstream for local protection<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3455\" data-end=\"3591\">SPDs for AC must match the system\u2019s nominal voltage and Uc while offering sufficient short-circuit withstand capability (Isccr).<\/p>\r\n<p data-start=\"3593\" data-end=\"3629\">Typical internal components include:<\/p>\r\n\r\n<ul data-start=\"3630\" data-end=\"3736\">\r\n \t<li data-start=\"3630\" data-end=\"3677\">\r\n<p data-start=\"3632\" data-end=\"3677\">MOVs for fast response and voltage clamping<\/p>\r\n<\/li>\r\n \t<li data-start=\"3678\" data-end=\"3736\">\r\n<p data-start=\"3680\" data-end=\"3736\">GDTs for high energy handling and isolation from leakage<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3738\" data-end=\"3801\">The combination of both ensures fast suppression and longevity.<\/p>\r\n\r\n<h3 data-start=\"3808\" data-end=\"3847\"><strong data-start=\"3812\" data-end=\"3847\">2. DC Power System Applications<\/strong><\/h3>\r\n<p data-start=\"3849\" data-end=\"3868\">DC systems such as:<\/p>\r\n\r\n<ul data-start=\"3869\" data-end=\"3979\">\r\n \t<li data-start=\"3869\" data-end=\"3894\">\r\n<p data-start=\"3871\" data-end=\"3894\">Telecom base stations<\/p>\r\n<\/li>\r\n \t<li data-start=\"3895\" data-end=\"3926\">\r\n<p data-start=\"3897\" data-end=\"3926\">Industrial control cabinets<\/p>\r\n<\/li>\r\n \t<li data-start=\"3927\" data-end=\"3946\">\r\n<p data-start=\"3929\" data-end=\"3946\">Battery storage<\/p>\r\n<\/li>\r\n \t<li data-start=\"3947\" data-end=\"3962\">\r\n<p data-start=\"3949\" data-end=\"3962\">EV charging<\/p>\r\n<\/li>\r\n \t<li data-start=\"3963\" data-end=\"3979\">\r\n<p data-start=\"3965\" data-end=\"3979\">Solar DC buses<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3981\" data-end=\"4095\">\u2026require SPDs designed specifically for continuous direct voltage, which lacks zero crossing and can sustain arcs.<\/p>\r\n<p data-start=\"4097\" data-end=\"4105\">DC SPDs:<\/p>\r\n\r\n<ul data-start=\"4106\" data-end=\"4332\">\r\n \t<li data-start=\"4106\" data-end=\"4143\">\r\n<p data-start=\"4108\" data-end=\"4143\">Typically use high-voltage MOVs<\/p>\r\n<\/li>\r\n \t<li data-start=\"4144\" data-end=\"4208\">\r\n<p data-start=\"4146\" data-end=\"4208\">Must handle high steady-state DC voltage without overheating<\/p>\r\n<\/li>\r\n \t<li data-start=\"4209\" data-end=\"4270\">\r\n<p data-start=\"4211\" data-end=\"4270\">Installed at DC panels, inverter inputs, or battery banks<\/p>\r\n<\/li>\r\n \t<li data-start=\"4271\" data-end=\"4332\">\r\n<p data-start=\"4273\" data-end=\"4332\">Help avoid system downtime due to surges or switching noise<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"4339\" data-end=\"4387\"><strong data-start=\"4343\" data-end=\"4387\">3. Photovoltaic (PV) System Applications<\/strong><\/h3>\r\n<p data-start=\"4389\" data-end=\"4540\">PV systems involve high DC voltages (up to 1500 VDC), large array surfaces, and frequent exposure to lightning surges due to rooftop or field mounting.<\/p>\r\n<p data-start=\"4542\" data-end=\"4576\">PV-specific SPDs must comply with:<\/p>\r\n\r\n<ul data-start=\"4577\" data-end=\"4615\">\r\n \t<li data-start=\"4577\" data-end=\"4597\">\r\n<p data-start=\"4579\" data-end=\"4597\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/26931\" target=\"_blank\" rel=\"nofollow noopener\"><strong data-start=\"4579\" data-end=\"4595\">IEC 61643-31<\/strong><\/a><\/p>\r\n<\/li>\r\n \t<li data-start=\"4598\" data-end=\"4615\">\r\n<p data-start=\"4600\" data-end=\"4615\"><a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/22527\/5b6a4f03275341d2bd18880b7a0877e7\/SIST-EN-50539-11-2013.pdf\" target=\"_blank\" rel=\"nofollow noopener\"><strong data-start=\"4600\" data-end=\"4615\">EN 50539-11<\/strong><\/a><\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4617\" data-end=\"4638\">They are deployed at:<\/p>\r\n\r\n<ul data-start=\"4639\" data-end=\"4791\">\r\n \t<li data-start=\"4639\" data-end=\"4685\">\r\n<p data-start=\"4641\" data-end=\"4685\"><strong data-start=\"4641\" data-end=\"4652\">DC side<\/strong>: Between the PV array and the inverter<\/p>\r\n<\/li>\r\n \t<li data-start=\"4686\" data-end=\"4740\">\r\n<p data-start=\"4688\" data-end=\"4740\"><strong data-start=\"4688\" data-end=\"4706\">Inverter input<\/strong>: For internal DC bus protection<\/p>\r\n<\/li>\r\n \t<li data-start=\"4741\" data-end=\"4791\">\r\n<p data-start=\"4743\" data-end=\"4791\"><strong data-start=\"4743\" data-end=\"4754\">AC side<\/strong>: Between the inverter and the grid interface<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4793\" data-end=\"4814\">Requirements include:<\/p>\r\n\r\n<ul data-start=\"4815\" data-end=\"4942\">\r\n \t<li data-start=\"4815\" data-end=\"4837\">\r\n<p data-start=\"4817\" data-end=\"4837\">High MCOV (Uc)<\/p>\r\n<\/li>\r\n \t<li data-start=\"4838\" data-end=\"4871\">\r\n<p data-start=\"4840\" data-end=\"4871\">Low protection level (Up)<\/p>\r\n<\/li>\r\n \t<li data-start=\"4872\" data-end=\"4891\">\r\n<p data-start=\"4874\" data-end=\"4891\">Long surge life<\/p>\r\n<\/li>\r\n \t<li data-start=\"4892\" data-end=\"4942\">\r\n<p data-start=\"4894\" data-end=\"4942\">Weather and UV resistance (for outdoor DC boxes)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"4944\" data-end=\"5038\">Well-placed PV SPDs reduce equipment replacement costs and improve system reliability and ROI.<\/p>\r\n\r\n<h2 data-start=\"5045\" data-end=\"5094\"><strong data-start=\"5048\" data-end=\"5094\">Understanding Iimp vs. Imax in SPD Ratings<\/strong><\/h2>\r\n<h3 data-start=\"5096\" data-end=\"5136\"><strong data-start=\"5100\" data-end=\"5136\">Impulse Discharge Current (Iimp)<\/strong><\/h3>\r\n<ul data-start=\"5138\" data-end=\"5403\">\r\n \t<li data-start=\"5138\" data-end=\"5174\">\r\n<p data-start=\"5140\" data-end=\"5174\">Characteristic of Type 1 SPD<\/p>\r\n<\/li>\r\n \t<li data-start=\"5175\" data-end=\"5216\">\r\n<p data-start=\"5177\" data-end=\"5216\">Simulates a direct lightning strike<\/p>\r\n<\/li>\r\n \t<li data-start=\"5217\" data-end=\"5255\">\r\n<p data-start=\"5219\" data-end=\"5255\">Tested with 10\/350 \u00b5s waveform<\/p>\r\n<\/li>\r\n \t<li data-start=\"5256\" data-end=\"5325\">\r\n<p data-start=\"5258\" data-end=\"5325\">Represents the SPD\u2019s capacity to handle a single extreme surge<\/p>\r\n<\/li>\r\n \t<li data-start=\"5326\" data-end=\"5403\">\r\n<p data-start=\"5328\" data-end=\"5403\">Suitable for building entry points or lightning arrestors downstream<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"5405\" data-end=\"5445\"><strong data-start=\"5409\" data-end=\"5445\">Maximum Discharge Current (Imax)<\/strong><\/h3>\r\n<ul data-start=\"5447\" data-end=\"5717\">\r\n \t<li data-start=\"5447\" data-end=\"5483\">\r\n<p data-start=\"5449\" data-end=\"5483\">Characteristic of Type 2 SPD<\/p>\r\n<\/li>\r\n \t<li data-start=\"5484\" data-end=\"5567\">\r\n<p data-start=\"5486\" data-end=\"5567\">Simulates multiple lower-energy surges from switching or indirect lightning<\/p>\r\n<\/li>\r\n \t<li data-start=\"5568\" data-end=\"5604\">\r\n<p data-start=\"5570\" data-end=\"5604\">Tested with 8\/20 \u00b5s waveform<\/p>\r\n<\/li>\r\n \t<li data-start=\"5605\" data-end=\"5643\">\r\n<p data-start=\"5607\" data-end=\"5643\">Reflects long-term surge endurance<\/p>\r\n<\/li>\r\n \t<li data-start=\"5644\" data-end=\"5717\">\r\n<p data-start=\"5646\" data-end=\"5717\">Suitable for distribution boards and equipment-level protection<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"5719\" data-end=\"5737\"><strong data-start=\"5722\" data-end=\"5736\">In summary<\/strong>:<\/p>\r\n\r\n<ul data-start=\"5738\" data-end=\"5943\">\r\n \t<li data-start=\"5738\" data-end=\"5796\">\r\n<p data-start=\"5740\" data-end=\"5796\"><strong data-start=\"5740\" data-end=\"5748\">Iimp<\/strong> = Peak endurance for rare, high-energy events<\/p>\r\n<\/li>\r\n \t<li data-start=\"5797\" data-end=\"5943\">\r\n<p data-start=\"5799\" data-end=\"5943\"><strong data-start=\"5799\" data-end=\"5807\">Imax<\/strong> = Repetitive endurance for frequent lower-energy transients<br data-start=\"5867\" data-end=\"5870\" \/>Both are essential in building a multi-level SPD protection strategy.<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h2 data-start=\"5950\" data-end=\"5967\"><strong data-start=\"5953\" data-end=\"5967\">Conclusion<\/strong><\/h2>\r\n<p data-start=\"5969\" data-end=\"6277\">Surge protective devices are essential for modern power systems, ensuring equipment safety and power continuity. Their classification into Type 1, 2, and 3, along with the understanding of technical parameters like Uc, Up, Iimp, and Imax, is vital for proper selection and implementation.<\/p>\r\n<p data-start=\"6279\" data-end=\"6457\">Whether protecting AC systems, DC automation, or solar PV, selecting the right SPD with suitable ratings helps reduce damage, lower O&amp;M costs, and extend system life.<\/p>\r\n<p data-start=\"6459\" data-end=\"6579\">A well-engineered SPD plan is a small investment that protects your large-scale infrastructure from irreversible damage.<\/p>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog\/784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media\/785"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/media?parent=784"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/de\/wp-json\/wp\/v2\/blog_category?post=784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}