{"id":879,"date":"2025-04-19T10:48:37","date_gmt":"2025-04-19T02:48:37","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=879"},"modified":"2025-04-19T11:23:19","modified_gmt":"2025-04-19T03:23:19","slug":"surge-protection-for-solar-photovoltaic-systems","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/da\/blog\/surge-protection-for-solar-photovoltaic-systems\/","title":{"rendered":"Oversp\u00e6ndingsbeskyttelse til solcelleanl\u00e6g"},"content":{"rendered":"<h2 data-start=\"52\" data-end=\"119\">Hvorfor oversp\u00e6ndingsbeskyttelsesanordninger er afg\u00f8rende for solcelleanl\u00e6g<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">De fjerntliggende steder, ekspansive layouter og udsatte overflader p\u00e5 solcelleanl\u00e6g (PV) g\u00f8r dem meget s\u00e5rbare over for milj\u00f8farer - is\u00e6r elektriske storme. En af de st\u00f8rste risici er skader for\u00e5rsaget af direkte eller indirekte lynnedslag, som kan f\u00f8re til l\u00e6ngere nedetid i systemet, inverterfejl og store indt\u00e6gtstab.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">S\u00e5dan v\u00e6lger og installerer du de rigtige PV-oversp\u00e6ndingsbeskyttelsesenheder<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Fotovoltaiske systemer fungerer under specifikke forhold, der kr\u00e6ver PV-oversp\u00e6ndingsbeskyttelsesenheder, der er specielt udviklet til h\u00f8jsp\u00e6ndings-DC-applikationer - ofte op til 1500V. I mods\u00e6tning til AC-systemer er DC-milj\u00f8et i solpaneler kontinuerligt og byder p\u00e5 unikke udfordringer.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">For at v\u00e6lge den korrekte SPD til dit solcelleanl\u00e6g skal du overveje f\u00f8lgende kritiske faktorer:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">Lynt\u00e6theden i installationsomr\u00e5det<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">Systemets driftstemperaturomr\u00e5de<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">Systemets DC-sp\u00e6ndingsklassificering (ofte op til 1500V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">Kortslutningsstr\u00f8mmen (Isc) af PV-panelet<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">Typen af \u200b\u200boversp\u00e6ndingseksponering (transient, direkte eller indirekte lyn)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">Den p\u00e5kr\u00e6vede nominelle afladningsstr\u00f8m (In) og beskyttelsesklasse (f.eks. Type 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">For at sikre effektiv beskyttelse skal sp\u00e6ndingsbeskyttelsesniveauet (Op) for den valgte SPD v\u00e6re mindst 20% lavere end den dielektriske styrke af det tilsluttede udstyr, s\u00e5som inverteren eller kombinationsboksen.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">Implementering af den rigtige lynbeskyttelse til solcelleanl\u00e6g er ikke kun en sikkerhedsforanstaltning - det er afg\u00f8rende for at opretholde systemets oppetid, forl\u00e6nge udstyrets levetid og beskytte din investering i vedvarende energi.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/da\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Oversp\u00e6ndingsbeskyttelsesanordninger til solcelleanl\u00e6g\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>DC &amp; AC Side SPD'er til kombinationsbokse og invertere<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes.","protected":false},"featured_media":880,"parent":0,"menu_order":138,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-879","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"The remote locations, exposed surface areas and extensive layouts of solar power plants put them at high risk of damage from the elements, particularly electrical storms.","txt":"<h2 data-start=\"52\" data-end=\"119\">Why Surge Protection Devices Are Essential for Solar PV Systems<\/h2>\r\n<p class=\"\" data-start=\"121\" data-end=\"486\">The remote locations, expansive layouts, and exposed surfaces of solar photovoltaic (PV) power plants make them highly vulnerable to environmental hazards \u2014 especially electrical storms. One of the biggest risks is damage caused by direct or indirect lightning strikes, which can lead to extended system downtime, inverter failure, and major revenue losses.<\/p>\r\n<p class=\"\" data-start=\"488\" data-end=\"819\">To mitigate these risks, it's crucial to install surge protection devices (SPDs) for solar PV systems at strategic points, including the solar inverter and array junction boxes. These solar surge protection solutions act as a first line of defence, preventing destructive overvoltages from damaging sensitive equipment.<\/p>\r\n\r\n<h2 data-start=\"826\" data-end=\"893\">How to Select and Install the Right PV Surge Protection Devices<\/h2>\r\n<p class=\"\" data-start=\"895\" data-end=\"1176\">Photovoltaic systems operate under specific conditions that require PV surge protection devices specifically engineered for high-voltage DC applications \u2014 often up to 1500V. Unlike AC systems, the DC environment in solar arrays is continuous and presents unique challenges.<\/p>\r\n<p class=\"\" data-start=\"1178\" data-end=\"1274\">To choose the correct SPD for your solar PV system, consider the following critical factors:<\/p>\r\n\r\n<ul data-start=\"1276\" data-end=\"1676\">\r\n \t<li class=\"\" data-start=\"1276\" data-end=\"1336\">\r\n<p class=\"\" data-start=\"1278\" data-end=\"1336\">The lightning flash density in the installation area<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1337\" data-end=\"1385\">\r\n<p class=\"\" data-start=\"1339\" data-end=\"1385\">The system\u2019s operating temperature range<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1386\" data-end=\"1444\">\r\n<p class=\"\" data-start=\"1388\" data-end=\"1444\">The system\u2019s DC voltage rating (often up to 1500V)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1445\" data-end=\"1500\">\r\n<p class=\"\" data-start=\"1447\" data-end=\"1500\">The short-circuit current (Isc) of the PV array<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1501\" data-end=\"1583\">\r\n<p class=\"\" data-start=\"1503\" data-end=\"1583\">The type of overvoltage exposure (transient, direct or indirect lightning)<\/p>\r\n<\/li>\r\n \t<li class=\"\" data-start=\"1584\" data-end=\"1676\">\r\n<p class=\"\" data-start=\"1586\" data-end=\"1676\">The required nominal discharge current (In) and protection class (e.g. Type 1+2 SPD)<\/p>\r\n<\/li>\r\n<\/ul>\r\n<p class=\"\" data-start=\"1678\" data-end=\"1893\">To ensure effective protection, the voltage protection level (Up) of the selected SPD must be at least 20% lower than the dielectric strength of the connected equipment, such as the inverter or combiner box.<\/p>\r\n<p class=\"\" data-start=\"1895\" data-end=\"2114\">Implementing the right lightning protection for solar PV is not just a safety measure \u2014 it\u2019s essential for maintaining system uptime, extending equipment lifespan, and protecting your investment in renewable energy.<\/p>\r\nIt is important to use an SPD with a short circuit withstand current greater than the short circuit current of the solar array string that the SPD is connected to. The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.\r\n\r\nWhen a lightning strikes at point A (see Figure 1), the solar PV panel and the inverter are likely to be damaged. Only the inverter will be damaged if the lightning strikes at point B. However, the inverter is typically the most expensive component within a PV system, which is why it is essential to properly select and install the correct SPD on both the ac and dc lines. The closer the strike is to the inverter, the more damaged the inverter will be.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/brpv3-600-type-2-surge-protection-device-for-pv-upto-600v\/\" rel=\"attachment wp-att-2054\"><img class=\"alignnone wp-image-2054 size-large\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2023\/07\/Surge-Protection-Devices-For-Solar-PV-1024x1024.webp\" alt=\"Surge Protection Devices For Solar PV\" width=\"1024\" height=\"1024\" \/><\/a>\r\n<h2><strong>DC &amp; AC Side SPDs for combiner boxes and inverters<\/strong><\/h2>\r\nSurge-protection devices are installed on the DC and AC sides of central and string inverters, in combiner boxes and to protect signal lines (measurements and communications). Depending on the atmospheric exposure of the PV plant to lightning, engineering, procurement and construction (EPC) contractors and designers may prescribe either standard type 2 IEC SPDs (indirect impact 8\/20 \u03bcs) or more robust type 1+2 SPDs (tested to withstand direct lightning impacts in 10\/350 \u03bcs waveform).\r\n\r\nDC side protection at combiner boxes and inverters typically has a Y-connection DIN-rail configuration in order to provide common and differential mode protection.\r\n\r\nOn the AC side, overvoltage protection of the inverter is likewise required. Whether at the inverter itself or at the AC combiner box, exposure to voltage surges is generally addressed by using standard DIN-rail type 2 SPDs in TN S, IT or even TT configurations.\r\n\r\nMoreover, depending on the PV installation, type 1+2 AC may be favored in some cases by EPC contractors and designers, in order to achieve a longer lifetime for SPDs and even protection where conditions are harsher in terms of the expected direct lightning impact. This will typically be the case in areas with a very high isoceraunic level, often associated with high altitudes."},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog\/879","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media\/880"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media?parent=879"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog_category?post=879"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}