{"id":825,"date":"2023-12-18T14:35:43","date_gmt":"2023-12-18T06:35:43","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=825"},"modified":"2024-09-05T16:31:35","modified_gmt":"2024-09-05T08:31:35","slug":"how-to-choose-surge-protection-devices","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/da\/blog\/how-to-choose-surge-protection-devices\/","title":{"rendered":"Hvordan v\u00e6lger man oversp\u00e6ndingsbeskyttelsesenheder?"},"content":{"rendered":"<strong>Valg af oversp\u00e6ndingsbeskyttere<\/strong>\r\n\r\nBritec\u2019s line of AC power surge protectors is designed to cover all possible configurations in low voltage installations. They are available in many versions, which differ in:\r\n\r\n\u2013 Type or test class (1, 2 or 3)\r\n\r\n\u2013 Operating voltage (Uc)\r\n\r\n\u2013 AC network configuration (Single\/three-Phase)\r\n\r\n\u2013 Discharge currents (Iimp, In, Imax, Uoc)\r\n\r\n\u2013 Protection level (Up)\r\n\r\n\u2013 Protection technology (varistors, spark gap, filter)\r\n\r\n\u2013 Features (differential mode, plug-in, remote signaling, compact).\r\n\r\nThe surge protection selection must be done following the local electrical code requirements (e.g.: minimum rating for In) and specific conditions (e.g.: high lightning density).\r\n\r\n<strong>Valg af type oversp\u00e6ndingsbeskyttere<\/strong>\r\n\r\nTypen af \u200b\u200boversp\u00e6ndingsbeskytter er baseret p\u00e5 dens placering og begr\u00e6nsningerne for den installation, der skal beskyttes.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"187\"><strong>Konfiguration<\/strong><\/td>\r\n<td width=\"104\"><strong>SPD<\/strong><\/td>\r\n<td width=\"180\"><strong>Beliggenhed<\/strong><\/td>\r\n<td width=\"98\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Installation udstyret med LPS eller kan blive ramt af lynet<\/td>\r\n<td width=\"104\">Type 1+2&nbsp;\r\n\r\nType 1+2+3<\/td>\r\n<td width=\"180\">Oprindelse af installationens oprindelse (panel eller hovedtavle)<\/td>\r\n<td width=\"98\">BR-50GR&nbsp;\r\n\r\nBR-25GR\r\n\r\nBR-25M\r\n\r\nBR-12.5M<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Installation uden LPS<\/td>\r\n<td width=\"104\">Type 2&nbsp;\r\n\r\nType 2+3<\/td>\r\n<td width=\"180\">hovedtavle<\/td>\r\n<td width=\"98\">BR-40&nbsp;\r\n\r\nBR-20<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Sekund\u00e6r beskyttelse (nedstr\u00f8ms prim\u00e6r SPD)<\/td>\r\n<td width=\"104\">Type 2&nbsp;\r\n\r\n(or Type 3)<\/td>\r\n<td width=\"180\">t\u00e6t p\u00e5 beskyttet udstyr<\/td>\r\n<td width=\"98\">BR-40DP&nbsp;\r\n\r\nBR-20DP<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Valg af driftssp\u00e6ndinger Uc og UT<\/strong>\r\n\r\nThe SPD Uc voltage (maximum continuous operating voltage) depends on:\r\n\r\n\u2013 Nominal voltage of the AC network (Uo)\r\n\r\n\u2013 Type of AC system (TN, TT, IT).\r\n\r\nThe level of resistance to temporary overvoltage (UT) is related to the Uc voltage. In addition, withstanding the \u201chigh voltage\u201d TOV (1200 Vac, 300A, 200ms) between Neutral and PE is needed in TT AC system.\r\n\r\n<strong>Driftssp\u00e6nding Uc (linje\/jord)<\/strong>\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"140\">AC netv\u00e6rk<\/td>\r\n<td colspan=\"3\" width=\"315\">230\/400V<\/td>\r\n<td width=\"114\">120\/208V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">AC system<\/td>\r\n<td width=\"104\">TT<\/td>\r\n<td width=\"104\">TN<\/td>\r\n<td width=\"107\">DET<\/td>\r\n<td width=\"114\">TN<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">Sp\u00e6nding Uc mini<\/td>\r\n<td width=\"104\">255V<\/td>\r\n<td width=\"104\">255V<\/td>\r\n<td width=\"107\">440V<\/td>\r\n<td width=\"114\">135V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">Sp\u00e6nding UT<\/td>\r\n<td width=\"104\">335\/440 V<\/td>\r\n<td width=\"104\">335\/440 V<\/td>\r\n<td width=\"107\">\u2014<\/td>\r\n<td width=\"114\">230\/175 V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">TOV N\/PE<\/td>\r\n<td width=\"104\">1200 V<\/td>\r\n<td width=\"104\"><\/td>\r\n<td width=\"107\"><\/td>\r\n<td width=\"114\"><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>At v\u00e6lge Iimp<\/strong>\r\n\r\nImpulsstr\u00f8mmen Iimp er defineret for Type 1 SPD. Minimumsv\u00e6rdien for Iimp er 12,5 kA pr. stang, if\u00f8lge IEC 60364-5-534. Dette niveau er tilpasset det virkelige f\u00e6nomen. Denne v\u00e6rdi kan dog \u00f8ges alt efter risikoen (beregning iht. EN 62305-1). BRITEC foresl\u00e5r i sit Type 1 SPD-omr\u00e5de 3 niveauer af Iimp-str\u00f8m efter pol: 12,5 kA, 25 kA og 50 kA.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"310\"><strong>Konfiguration<\/strong><\/td>\r\n<td width=\"132\"><strong>Iimp\/stang<\/strong><\/td>\r\n<td width=\"126\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">Maksimal risiko<\/td>\r\n<td width=\"132\">50kA<\/td>\r\n<td width=\"126\">BR-50GR<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">Meget h\u00f8j lynt\u00e6thed D\u00e5rlig jording<\/td>\r\n<td width=\"132\">25kA<\/td>\r\n<td width=\"126\">BR-25GR&nbsp;\r\n\r\nBR-25M<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">H\u00f8j, medium eller lav lynt\u00e6thed<\/td>\r\n<td width=\"132\">12,5kA<\/td>\r\n<td width=\"126\">BR-12,5M<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>V\u00e6lger I nuv\u00e6rende<\/strong>\r\n\r\nThe relevant nominal discharge current In for the SPD is in relation with the lightning risk in the installation area.\r\n\r\nThe minimum rating of In for a SPD connected at the installation entrance is 5 kA (8\/20 \u03bcs waveform), required by standard.\r\n\r\nNevertheless higher ratings are advised in case of high lightning density.\r\n\r\nMoreover higher values of In current will increase the SPD lifetime.\r\n\r\nImax (max. discharge current) rating is linked to In.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"338\"><strong>Betingelser<\/strong><\/td>\r\n<td width=\"113\"><strong>I<\/strong><\/td>\r\n<td width=\"117\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">Meget h\u00f8j lynt\u00e6thed<\/td>\r\n<td width=\"113\">&gt; 20 kA<\/td>\r\n<td width=\"117\">BR-60&nbsp;\r\n\r\nBR-70<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">H\u00f8j eller medium lynt\u00e6thed<\/td>\r\n<td width=\"113\">10-20 kA<\/td>\r\n<td width=\"117\">BR-40&nbsp;\r\n\r\nBR-20<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">Lav lynt\u00e6thed eller sekund\u00e6r SPD<\/td>\r\n<td width=\"113\">5 kA<\/td>\r\n<td width=\"117\">BR-15DP<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Valg af beskyttelsesniveau op<\/strong>\r\n\r\nThe user must select a surge protector with a protection level Up adapted to the withstand level of terminal equipment. In every case, the lower the protection level Up, the better the protection.\r\n\r\nIEC 60364 standard calls for the minimum protection level of 2.5 kV for a SPD connected at the entrance of a 230\/400 V network: this level is in compliance with the withstand of robust devices (electromechanical type).\r\n\r\nElectronic-based terminals have lower impulse withstand and require a better protection: so, surge protectors with 1.5 kV protection are necessary to provide efficient protection.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td rowspan=\"2\" width=\"300\"><strong>Betingelser<\/strong><\/td>\r\n<td colspan=\"2\" width=\"268\"><strong>Anbefalet op<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"142\">230\/400 V&nbsp;\r\n\r\nAC network<\/td>\r\n<td width=\"126\">120\/208 V&nbsp;\r\n\r\nAC network<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">SPD ved installationens indgang<\/td>\r\n<td width=\"142\">2,5 kV maks.<\/td>\r\n<td width=\"126\">1,5 kV maks.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">Elektromekanisk beskyttet udstyr<\/td>\r\n<td width=\"142\">2,5 kV<\/td>\r\n<td width=\"126\">1,5 kV<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">Elektronisk-baseret beskyttet udstyr<\/td>\r\n<td width=\"142\">1,5 kV<\/td>\r\n<td width=\"126\">0,8 kV<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;","protected":false},"featured_media":826,"parent":0,"menu_order":164,"template":"","meta":{"_acf_changed":false},"blog_category":[8],"class_list":["post-825","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-company-news"],"acf":{"des":"Britec\u2019s line of AC power surge protectors is designed to cover all possible configurations in low voltage installations.","txt":"<strong>Choosing Surge Protectors<\/strong>\r\n\r\nBritec\u2019s line of AC power surge protectors is designed to cover all possible configurations in low voltage installations. They are available in many versions, which differ in:\r\n\r\n\u2013 Type or test class (1, 2 or 3)\r\n\r\n\u2013 Operating voltage (Uc)\r\n\r\n\u2013 AC network configuration (Single\/three-Phase)\r\n\r\n\u2013 Discharge currents (Iimp, In, Imax, Uoc)\r\n\r\n\u2013 Protection level (Up)\r\n\r\n\u2013 Protection technology (varistors, spark gap, filter)\r\n\r\n\u2013 Features (differential mode, plug-in, remote signaling, compact).\r\n\r\nThe surge protection selection must be done following the local electrical code requirements (e.g.: minimum rating for In) and specific conditions (e.g.: high lightning density).\r\n\r\n<strong>Choosing the Type of surge protectors<\/strong>\r\n\r\nThe type of surge protector is based on its location and the constraints of the installation to be protected.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"187\"><strong>Configuration<\/strong><\/td>\r\n<td width=\"104\"><strong>SPD<\/strong><\/td>\r\n<td width=\"180\"><strong>Location<\/strong><\/td>\r\n<td width=\"98\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Installation equipped with LPS or could be hit by lightning<\/td>\r\n<td width=\"104\">Type 1+2&nbsp;\r\n\r\nType 1+2+3<\/td>\r\n<td width=\"180\">Origin of the installation origin (Panel or main switchboard)<\/td>\r\n<td width=\"98\">BR-50GR&nbsp;\r\n\r\nBR-25GR\r\n\r\nBR-25M\r\n\r\nBR-12.5M<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Installation without LPS<\/td>\r\n<td width=\"104\">Type 2&nbsp;\r\n\r\nType 2+3<\/td>\r\n<td width=\"180\">main switchboard<\/td>\r\n<td width=\"98\">BR-40&nbsp;\r\n\r\nBR-20<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"187\">Secondary protection (downstream primary SPD)<\/td>\r\n<td width=\"104\">Type 2&nbsp;\r\n\r\n(or Type 3)<\/td>\r\n<td width=\"180\">close to protected equipment<\/td>\r\n<td width=\"98\">BR-40DP&nbsp;\r\n\r\nBR-20DP<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Choosing the operating voltages Uc and UT<\/strong>\r\n\r\nThe SPD Uc voltage (maximum continuous operating voltage) depends on:\r\n\r\n\u2013 Nominal voltage of the AC network (Uo)\r\n\r\n\u2013 Type of AC system (TN, TT, IT).\r\n\r\nThe level of resistance to temporary overvoltage (UT) is related to the Uc voltage. In addition, withstanding the \u201chigh voltage\u201d TOV (1200 Vac, 300A, 200ms) between Neutral and PE is needed in TT AC system.\r\n\r\n<strong>Operating voltage Uc (Line\/Ground)<\/strong>\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"140\">AC Network<\/td>\r\n<td colspan=\"3\" width=\"315\">230\/400V<\/td>\r\n<td width=\"114\">120\/208V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">AC system<\/td>\r\n<td width=\"104\">TT<\/td>\r\n<td width=\"104\">TN<\/td>\r\n<td width=\"107\">IT<\/td>\r\n<td width=\"114\">TN<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">Voltage Uc mini<\/td>\r\n<td width=\"104\">255V<\/td>\r\n<td width=\"104\">255V<\/td>\r\n<td width=\"107\">440V<\/td>\r\n<td width=\"114\">135V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">Voltage UT<\/td>\r\n<td width=\"104\">335\/440 V<\/td>\r\n<td width=\"104\">335\/440 V<\/td>\r\n<td width=\"107\">\u2014<\/td>\r\n<td width=\"114\">230\/175 V<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"140\">TOV N\/PE<\/td>\r\n<td width=\"104\">1200 V<\/td>\r\n<td width=\"104\"><\/td>\r\n<td width=\"107\"><\/td>\r\n<td width=\"114\"><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Choosing Iimp<\/strong>\r\n\r\nThe impulse current Iimp is defined for Type 1 SPD. The minimum rating for Iimp is 12.5 kA by pole, following IEC 60364-5-534. This level is adapted to the real phenomenon. This value can, however, be increased according to the risk (calculation according to EN 62305-1). BRITEC proposes, in its Type 1 SPD range, 3 levels of Iimp current by pole: 12.5kA, 25kA and 50 kA.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"310\"><strong>Configuration<\/strong><\/td>\r\n<td width=\"132\"><strong>Iimp\/pole<\/strong><\/td>\r\n<td width=\"126\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">Maximum risk<\/td>\r\n<td width=\"132\">50kA<\/td>\r\n<td width=\"126\">BR-50GR<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">Very high lightning density Bad earthing<\/td>\r\n<td width=\"132\">25kA<\/td>\r\n<td width=\"126\">BR-25GR&nbsp;\r\n\r\nBR-25M<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"310\">High, medium or low lightning density<\/td>\r\n<td width=\"132\">12.5kA<\/td>\r\n<td width=\"126\">BR-12.5M<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Choosing In current<\/strong>\r\n\r\nThe relevant nominal discharge current In for the SPD is in relation with the lightning risk in the installation area.\r\n\r\nThe minimum rating of In for a SPD connected at the installation entrance is 5 kA (8\/20 \u03bcs waveform), required by standard.\r\n\r\nNevertheless higher ratings are advised in case of high lightning density.\r\n\r\nMoreover higher values of In current will increase the SPD lifetime.\r\n\r\nImax (max. discharge current) rating is linked to In.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td width=\"338\"><strong>Conditions<\/strong><\/td>\r\n<td width=\"113\"><strong>In<\/strong><\/td>\r\n<td width=\"117\"><strong>BRITEC<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">Very high lightning density<\/td>\r\n<td width=\"113\">&gt; 20 kA<\/td>\r\n<td width=\"117\">BR-60&nbsp;\r\n\r\nBR-70<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">High or medium lightning density<\/td>\r\n<td width=\"113\">10-20 kA<\/td>\r\n<td width=\"117\">BR-40&nbsp;\r\n\r\nBR-20<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"338\">Low lightning density or secondary SPD<\/td>\r\n<td width=\"113\">5 kA<\/td>\r\n<td width=\"117\">BR-15DP<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<strong>Choosing the protection level Up<\/strong>\r\n\r\nThe user must select a surge protector with a protection level Up adapted to the withstand level of terminal equipment. In every case, the lower the protection level Up, the better the protection.\r\n\r\nIEC 60364 standard calls for the minimum protection level of 2.5 kV for a SPD connected at the entrance of a 230\/400 V network: this level is in compliance with the withstand of robust devices (electromechanical type).\r\n\r\nElectronic-based terminals have lower impulse withstand and require a better protection: so, surge protectors with 1.5 kV protection are necessary to provide efficient protection.\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td rowspan=\"2\" width=\"300\"><strong>Conditions<\/strong><\/td>\r\n<td colspan=\"2\" width=\"268\"><strong>Recommended Up<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"142\">230\/400 V&nbsp;\r\n\r\nAC network<\/td>\r\n<td width=\"126\">120\/208 V&nbsp;\r\n\r\nAC network<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">SPD at the installation entrance<\/td>\r\n<td width=\"142\">2.5 kV max.<\/td>\r\n<td width=\"126\">1.5 kV max.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">Electromechanical protected equipment<\/td>\r\n<td width=\"142\">2.5 kV<\/td>\r\n<td width=\"126\">1.5 kV<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"300\">Electronic-based protected equipment<\/td>\r\n<td width=\"142\">1.5 kV<\/td>\r\n<td width=\"126\">0.8 kV<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog\/825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media\/826"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media?parent=825"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog_category?post=825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}