{"id":2551,"date":"2026-08-04T09:40:07","date_gmt":"2026-08-04T01:40:07","guid":{"rendered":"https:\/\/www.britecelectric.com\/?post_type=blog&#038;p=2551"},"modified":"2026-08-26T13:14:15","modified_gmt":"2026-08-26T05:14:15","slug":"do-you-need-type-1-surge-protection-device-in-lightning-prone-regions","status":"publish","type":"blog","link":"https:\/\/www.britecelectric.com\/da\/blog\/do-you-need-type-1-surge-protection-device-in-lightning-prone-regions\/","title":{"rendered":"Do You Need Type 1 Surge Protection Device in Lightning-Prone Regions?"},"content":{"rendered":"If your facility is located in a region with frequent thunderstorms, the question is not whether you need surge protection, but whether a standard Type 2 SPD is sufficient or whether a <strong>Type 1 oversp\u00e6ndingsbeskyttelsesanordning<\/strong> is required at the service entrance. The answer depends on three factors defined by <strong>IEC 62305<\/strong> og <strong>IEC 61643-11<\/strong>: whether your building has an external lightning protection system, whether power is supplied via overhead lines, and the local lightning density (keraunic level). This guide explains exactly when a Type 1 SPD is mandatory, what happens if you install the wrong type, and how to select the right configuration for your installation. For an overview of all SPD types, see our <a href=\"https:\/\/www.britecelectric.com\/da\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">surge protection device overview<\/a>.\r\n<div style=\"background: #f0f8f8; border-left: 4px solid #009292; padding: 20px 24px; margin: 24px 0; border-radius: 0 8px 8px 0;\">\r\n<p style=\"font-size: 18px; font-weight: bold; color: #009292; margin: 0 0 8px 0;\">Protect Your Facility From Direct Lightning Current<\/p>\r\n<p style=\"font-size: 14px; color: #444; line-height: 1.6; margin: 0 0 16px 0;\">Britec Electric manufactures IEC 61643-11 certified Type 1 SPDs rated at Iimp 25kA (10\/350\u00b5s), engineered for installations in high-lightning regions worldwide. Our BR-25M series handles partial lightning current at the service entrance, protecting your downstream equipment and Type 2 SPDs from catastrophic failure.<\/p>\r\n<a style=\"display: inline-block; background: #009292; color: #fff; font-size: 15px; font-weight: bold; padding: 12px 32px; border-radius: 6px; text-decoration: none;\" href=\"https:\/\/www.britecelectric.com\/da\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Request a Free Quote<\/a>\r\n\r\n<\/div>\r\n<h2>What Makes a Region \"Lightning-Prone\"?<\/h2>\r\nLightning activity varies dramatically across the globe. The <strong>keraunic level<\/strong> (also called thunderstorm days, Td) is the traditional metric: the average number of days per year on which thunder is heard at a given location. According to data from NASA and Vaisala, the global distribution ranges from near zero in polar regions to over 200 days per year in the tropics.\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0; font-size: 14px;\">\r\n<thead>\r\n<tr style=\"background: #009292; color: #fff;\">\r\n<th style=\"padding: 10px 12px; text-align: left; border: 1px solid #007a7a;\">Region \/ Country<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Keraunic Level (Td)<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Lightning Density (flashes\/km\u00b2\/yr)<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Type 1 SPD Recommendation<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Central Africa (DRC, Cameroon)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">150\u2013200+<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">50\u2013205<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Southeast Asia (Singapore, Malaysia, Indonesia)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">150\u2013180<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">20\u201380<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Florida, USA (\"Lightning Alley\")<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80\u2013100<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">9\u201324<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Northern Australia (Darwin)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u201330<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Central Europe (Germany, Austria, Switzerland)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u201335<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">2\u20135<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Risk assessment required<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">South America (Brazil, Colombia, Venezuela)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80\u2013297 (Lake Maracaibo)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u2013233<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nAs a practical rule, when the keraunic level exceeds <strong>25 thunderstorm days per year<\/strong>, a formal <a href=\"https:\/\/www.britecelectric.com\/da\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">lightning risk assessment<\/a> per IEC 62305-2 should be conducted. In regions above 50 Td, a Type 1 SPD at the service entrance is recommended as a baseline, even before completing the full risk calculation.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-31-type-1-25ka-surge-arrester-for-tt-and-tns\/\"><img class=\"alignnone size-full wp-image-2428\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-4.jpg\" alt=\"BR-25M 3+1 Type 1 25kA oversp\u00e6ndingsafleder til TT og TNS\" width=\"800\" \/><\/a>\r\n<h2>When Is a Type 1 SPD Mandatory?<\/h2>\r\nIf\u00f8lge <strong>IEC 60364-5-53<\/strong> og <strong>IEC 62305-4<\/strong>, a Type 1 SPD is mandatory at the main distribution board (LPZ 0 \u2192 LPZ 1 boundary) under two specific conditions:\r\n<h3>1. The Building Has an External Lightning Protection System (LPS)<\/h3>\r\nWhen a building is equipped with an external lightning protection system comprising air terminals (lightning rods), down conductors, and an earth termination network per IEC 62305-3, a direct lightning strike to the air terminal will inject partial lightning current into the building's electrical system through the common earthing network. This partial current has the 10\/350 microsecond waveform and can reach tens of kiloamperes. Only a Type 1 SPD certified to IEC 61643-11 Class I can safely discharge this energy to earth without catastrophic failure.\r\n<h3>2. The Building Is Supplied by Overhead Power Lines<\/h3>\r\nOverhead power lines are directly exposed to lightning. A direct strike to the line, or a nearby strike that induces surge current through electromagnetic coupling, can propagate the 10\/350 microsecond lightning waveform into the building's main distribution board. IEC 60364-5-53 requires a Type 1 SPD at or near the origin of the electrical installation whenever overhead supply lines are present, regardless of whether the building itself has an external LPS.\r\n<div style=\"background: #fff8e1; border-left: 4px solid #f9a825; padding: 16px 20px; margin: 20px 0; border-radius: 0 6px 6px 0;\">\r\n<p style=\"font-size: 14px; color: #555; line-height: 1.6; margin: 0;\"><strong>Key distinction:<\/strong> A building with underground supply and no external LPS may be protected by a Type 2 SPD at the MDB, subject to risk assessment. However, in high-keraunic regions, even underground cables can carry induced lightning current through ground potential rise, making a combined Type 1+2 SPD the safer engineering choice.<\/p>\r\n\r\n<\/div>\r\n<h2>Why Type 2 SPDs Cannot Substitute for Type 1<\/h2>\r\nThe critical technical difference between Type 1 and Type 2 SPDs is the <strong>test waveform<\/strong>. IEC 61643-11 defines:\r\n<ul>\r\n \t<li><strong>Type 1 (Class I):<\/strong> Tested with 10\/350\u00b5s lightning impulse current (Iimp). This waveform simulates partial direct lightning current. At 25kA peak, the 10\/350\u00b5s impulse carries a specific energy (W\/R) of approximately 156 kJ\/\u03a9.<\/li>\r\n \t<li><strong>Type 2 (Class II):<\/strong> Tested with 8\/20\u00b5s nominal discharge current (In). This waveform simulates switching surges and induced lightning surges. At 20kA peak, the 8\/20\u00b5s impulse carries only about 7.4 kJ\/\u03a9 of specific energy.<\/li>\r\n<\/ul>\r\nAt the same peak current, the 10\/350\u00b5s waveform delivers <strong>10 to 20 times more total energy<\/strong> than the 8\/20\u00b5s waveform because of its long duration tail (350 microseconds vs 20 microseconds at the half-value point). When a Type 2 SPD is subjected to 10\/350\u00b5s current, its MOV elements absorb energy far exceeding their thermal rating, resulting in:\r\n<ul>\r\n \t<li>Immediate MOV rupture or shattering<\/li>\r\n \t<li>Housing deformation or fire<\/li>\r\n \t<li>Loss of protection at the exact moment the lightning strike occurs<\/li>\r\n \t<li>Potential short-circuit from line to earth, tripping upstream protection and disconnecting the entire installation<\/li>\r\n<\/ul>\r\nThis is why IEC 61643-11 and IEC 62305-4 strictly prohibit substituting a Type 2 SPD for a Type 1 SPD at the LPZ 0 \u2192 LPZ 1 boundary.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\"><img class=\"alignnone size-full wp-image-2430\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-3.jpg\" alt=\"BR-25M 1+1 Type 1 25kA oversp\u00e6ndingsafleder til TT og TNS\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>Type 1 SPD Product Selection for Lightning-Prone Regions<\/h2>\r\nDe <a href=\"https:\/\/www.britecelectric.com\/da\/\" target=\"_blank\" rel=\"noopener\">Britec Electric<\/a> BR-25M series is engineered for installations in lightning-prone regions. These SPDs are classified as Type 1+2+3 combined devices, certified to IEC 61643-11 and EN 61643-11, with an Iimp of 25kA (10\/350\u00b5s) and Imax of 120kA (8\/20\u00b5s).\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0; font-size: 14px;\">\r\n<thead>\r\n<tr style=\"background: #009292; color: #fff;\">\r\n<th style=\"padding: 10px 12px; text-align: left; border: 1px solid #007a7a;\">Parameter<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">BR-25M 1P<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">BR-25M 1+1<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Anvendelse<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">SPD Type (IEC 61643-11)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Klasse I + II + III<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Klasse I + II + III<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Service entrance, LPZ 0\u21921<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Iimp (10\/350\u00b5s)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">25kA<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">25kA (L-N) \/ 50kA (N-PE)<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Partial lightning current<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Imax (8\/20\u00b5s)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">120kA<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">120kA<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Switching surges<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Uc (275V variant)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">275V<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">275V \/ 255V<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">230\/400V systems<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Op<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">\u22641,3kV<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">\u22641.3kV \/ \u22641.5kV<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Below Category IV Uw<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Earthing system<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">TN-S, TN-C-S<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">TT, TN-S<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Match to installation<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Max backup fuse<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">200A gG<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">200A gG<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">SCPD coordination<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nFor single-phase TN-S systems, the <a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-1p-type-1-25ka-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1P Type 1 25kA surge arrester<\/a> provides single-pole L-PE protection. For TT systems or TN-S systems with transformer-side neutral earthing, the <a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1+1 Type 1 25kA for TT and TN-S<\/a> provides the L-N + N-PE configuration required by IEC 60364-5-53.\r\n<h2>Cascade Coordination: Type 1 + Type 2 Strategy<\/h2>\r\nInstalling a Type 1 SPD alone is not a complete protection strategy. IEC 62305-4 defines a <strong>koordineret SPD-system<\/strong> where multiple SPD types are installed at successive LPZ boundaries to progressively reduce surge voltage to levels that sensitive equipment can withstand.\r\n\r\nThe standard cascade for lightning-prone regions is:\r\n<ul>\r\n \t<li><strong>LPZ 0 \u2192 LPZ 1 (main distribution board):<\/strong> Type 1 SPD with Iimp \u2265 25kA. Discharges partial lightning current to earth. Up \u2264 1.5kV.<\/li>\r\n \t<li><strong>LPZ 1 \u2192 LPZ 2 (sub-distribution board):<\/strong> Type 2 SPD with In \u2265 20kA. Further reduces residual surge voltage. Up \u2264 1.4kV.<\/li>\r\n \t<li><strong>LPZ 2 \u2192 LPZ 3 (equipment terminal):<\/strong> Type 3 SPD with Uoc \u2264 10kV. Fine protection for sensitive electronics. Up \u2264 1.0kV.<\/li>\r\n<\/ul>\r\nWhen a Type 1 and Type 2 SPD are installed in the same system, they must be separated by at least <strong>10 metres of cable<\/strong> between their installation points. If the physical distance is less than 10 metres, install a decoupling <a href=\"https:\/\/www.britecelectric.com\/da\/product\/brci-coordination-inductor\/\" target=\"_blank\" rel=\"noopener\">coordination inductor<\/a> between the two positions, or use a combined Type 1+2 device. For detailed guidance on SPD-to-circuit-breaker coordination, see our article on <a href=\"https:\/\/www.britecelectric.com\/da\/blog\/ac-spd-single-phase-coordination-circuit-breakers\/\" target=\"_blank\" rel=\"noopener\">AC SPD single phase coordination with circuit breakers<\/a>.\r\n<h2>Backup Protection for Type 1 SPDs<\/h2>\r\nEvery Type 1 SPD must have an upstream short-circuit protective device (SCPD) to safely disconnect the SPD when its internal MOV reaches end-of-life and fails in short-circuit mode. For the BR-25M series with Iimp 25kA, the maximum permitted backup fuse is <strong>200A gG<\/strong>.\r\n\r\nWhile standard gG fuses or Type C\/D MCBs can serve as the SCPD, dedicated SPD backup protectors offer superior coordination. The <a href=\"https:\/\/www.britecelectric.com\/da\/product\/brscb-i-25-class-i-25ka-dedicated-backup-protector\/\" target=\"_blank\" rel=\"noopener\">BRSCB-I-25 Class I 25kA dedicated backup protector<\/a> is specifically engineered for Type 1 SPD coordination:\r\n<ul>\r\n \t<li>Withstands 25kA at 10\/350\u00b5s without nuisance tripping<\/li>\r\n \t<li>Cuts leakage current to under 3A when the SPD fails<\/li>\r\n \t<li>Available in 1P, 2P, 3P, and 4P configurations<\/li>\r\n \t<li>Visual status indicator: green (normal) \/ red (fault)<\/li>\r\n<\/ul>\r\nFor installations using a combined Type 2 SPD with integrated MCB, the <a href=\"https:\/\/www.britecelectric.com\/da\/product\/brcb-15-30-40-type-2-surge-protection-device-combined-with-mini-circuit-breaker\/\" target=\"_blank\" rel=\"noopener\">BRCB-15\/30\/40 Type 2 SPD combined with MCB<\/a> provides a compact all-in-one solution for sub-distribution boards.\r\n<h2>Common Mistakes in Lightning-Prone Region Installations<\/h2>\r\n<h3>Mistake 1: Relying on Type 2 Alone<\/h3>\r\nThe most dangerous and common mistake. In buildings with external LPS or overhead supply, a Type 2 SPD at the service entrance will fail catastrophically during the first significant lightning event, leaving all downstream equipment unprotected.\r\n<h3>Mistake 2: Ignoring the Keraunic Level<\/h3>\r\nMany specifiers use the same SPD specification across all project locations. A design adequate for Central Europe (Td 15\u201335) is insufficient for a project in Southeast Asia (Td 150+). Always check the local keraunic level and conduct an IEC 62305-2 risk assessment.\r\n<h3>Mistake 3: Mismatched Earthing System and SPD Configuration<\/h3>\r\nInstalling a 1P SPD in a TT system, or a 1+1 SPD in a TN-C system, creates protection gaps. Verify the earthing system with a qualified electrician before selecting the SPD pole configuration.\r\n<h3>Mistake 4: Excessive Lead Length<\/h3>\r\nIEC 61643-12 requires total SPD lead length (busbar \u2192 SPD \u2192 PE bar) not to exceed 0.5 metres. Every extra metre adds approximately 1\u00b5H of inductance, which at 10kA\/\u00b5s di\/dt adds 10kV of residual voltage, completely negating the SPD's clamping performance.\r\n<h3>Mistake 5: No Annual Inspection Programme<\/h3>\r\nSPDs are sacrificial devices. In high-lightning regions, a Type 1 SPD may reach end-of-life within 3\u20135 years. Without annual visual inspection of the green\/red status indicator, a failed SPD can sit unnoticed for years, providing zero protection.\r\n<h3>Mistake 6: Skipping the Coordination Inductor<\/h3>\r\nWhen Type 1 and Type 2 SPDs are installed less than 10 metres apart without a coordination inductor, the faster-responding Type 2 activates first and absorbs more energy than its rating allows, causing premature failure.\r\n<div style=\"background: #f0f8f8; border-left: 4px solid #009292; padding: 20px 24px; margin: 24px 0; border-radius: 0 8px 8px 0;\">\r\n<p style=\"font-size: 18px; font-weight: bold; color: #009292; margin: 0 0 8px 0;\">Get Expert Guidance on Your Lightning Protection Strategy<\/p>\r\n<p style=\"font-size: 14px; color: #444; line-height: 1.6; margin: 0 0 16px 0;\">Not sure which Type 1 SPD configuration your project needs? Our engineering team helps B2B clients worldwide select the right IEC 61643-11 certified SPDs based on local keraunic levels, earthing systems, and cascade coordination requirements. We also provide dedicated backup protectors and coordination inductors for complete system protection.<\/p>\r\n<a style=\"display: inline-block; background: linear-gradient(135deg, #009292, #00b3b3); color: #fff; font-size: 15px; font-weight: bold; padding: 12px 32px; border-radius: 6px; text-decoration: none;\" href=\"https:\/\/www.britecelectric.com\/da\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Get a Free Quote Now<\/a>\r\n\r\n<\/div>\r\n<h2>Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\r\n<h3>1. When is a Type 1 SPD mandatory?<\/h3>\r\nA Type 1 SPD is mandatory in two scenarios defined by IEC 60364-5-53 and IEC 62305-4: first, when the building has an external lightning protection system (LPS) with air terminals, down conductors, and an earth termination system; second, when the building is supplied by overhead power lines that can carry direct or nearby lightning strikes into the electrical installation. In both cases, partial lightning current with the 10\/350 microsecond waveform can enter the building's main distribution board, and only a Type 1 SPD tested to IEC 61643-11 Class I can safely discharge this energy.\r\n<h3>2. What is the difference between Type 1 and Type 2 SPD?<\/h3>\r\nThe fundamental difference is the test waveform. Type 1 SPDs are tested with the 10\/350 microsecond lightning impulse current (Iimp), which simulates partial direct lightning current and carries 10 to 20 times more total energy than the 8\/20 microsecond waveform used for Type 2 SPDs. Type 1 SPDs install at the LPZ 0 to 1 boundary (main distribution board) to handle lightning current entering the building. Type 2 SPDs install at the LPZ 1 to 2 boundary (sub-distribution boards) to handle switching surges and residual lightning energy. A Type 2 SPD cannot substitute for a Type 1 SPD where Type 1 is required.\r\n<h3>3. What keraunic level requires Type 1 surge protection?<\/h3>\r\nThere is no single keraunic threshold that automatically mandates a Type 1 SPD, but IEC 62305-2 risk assessment becomes critical when the keraunic level (thunderstorm days per year) exceeds 25. Regions with keraunic levels above 50, such as Florida (80\u2013100 thunderstorm days), Singapore (180 days), and Central Africa (150\u2013200 days), have a high probability of direct or nearby lightning strikes. In these regions, if the building has an external LPS or is supplied by overhead lines, Type 1 SPD installation is effectively mandatory.\r\n<h3>4. Can a Type 2 SPD handle lightning current?<\/h3>\r\nNo. A Type 2 SPD is tested with the 8\/20 microsecond waveform at a nominal discharge current (In) of up to 20kA. The 10\/350 microsecond lightning waveform carries significantly more energy because of its long duration tail. When a Type 2 SPD is subjected to 10\/350 microsecond current, the MOV elements absorb 10 to 20 times their rated thermal energy, causing immediate catastrophic failure at the exact moment protection is needed most.\r\n<h3>5. What is Iimp and why does it matter for lightning-prone regions?<\/h3>\r\nIimp (impulse current) is the peak current value of the 10\/350 microsecond test waveform used to certify Type 1 SPDs per IEC 61643-11. It represents the partial lightning current that the SPD must safely discharge to earth. For residential and small commercial installations in lightning-prone regions, Iimp of 12.5kA per pole is the minimum acceptable value. For buildings with external lightning protection systems, IEC 62305-4 typically requires Iimp of at least 25kA per pole at the service entrance.\r\n<h3>6. Do I need a Type 1 SPD if my building has no lightning rod?<\/h3>\r\nIf your building has no external lightning protection system (LPS) and is supplied exclusively by underground cables, a Type 1 SPD is not strictly mandatory under IEC 60364-5-53. However, in lightning-prone regions with high keraunic levels, a risk assessment per IEC 62305-2 may still recommend a combined Type 1+2 SPD at the main distribution board, because nearby strikes can induce surge currents into underground cables through ground potential rise.\r\n<h3>7. How do I choose between 1P and 1+1 Type 1 SPD configurations?<\/h3>\r\nA 1P (single-pole) Type 1 SPD connects between line and protective earth (L-PE) and is used in TN-S and TN-C-S earthing systems. A 1+1 (1P+N) configuration consists of two modules: one between line and neutral (L-N) and one between neutral and earth (N-PE). The 1+1 configuration is required for TT earthing systems and for TN-S systems where the neutral-earth bond is at the transformer. Always match the SPD configuration to your earthing system as verified by a qualified electrician.\r\n<h3>8. What backup protection does a Type 1 SPD need?<\/h3>\r\nEvery Type 1 SPD requires an upstream short-circuit protective device (SCPD) to safely disconnect the SPD if its internal MOV fails in short-circuit mode. For Type 1 SPDs with Iimp of 25kA, the maximum permitted backup fuse is typically 200A gG. Dedicated SPD backup protectors such as the Britec BRSCB-I-25 are engineered specifically for lightning impulse coordination, cutting leakage current to under 3A and withstanding 25kA at 10\/350 microseconds without nuisance tripping.\r\n<h3>9. What happens if I only install a Type 2 SPD in a lightning-prone area?<\/h3>\r\nInstalling only a Type 2 SPD where a Type 1 is required creates a dangerous false sense of security. When lightning current with the 10\/350 microsecond waveform enters the installation, the Type 2 SPD will attempt to absorb energy far exceeding its rating. The result is immediate catastrophic failure: the MOV elements can shatter, the SPD housing can rupture, and the protected equipment is left exposed to the full lightning impulse. The cost of upgrading from Type 2 to Type 1+2 is minimal compared to the cost of equipment damage and downtime after a strike.\r\n<h3>10. How often should Type 1 SPDs be inspected or replaced in high-lightning areas?<\/h3>\r\nIn lightning-prone regions, Type 1 SPDs should be inspected at least once per year, and immediately after any known direct lightning strike to the building or nearby utility infrastructure. SPDs are sacrificial devices that degrade with each surge event. The thermal disconnection indicator window should be checked visually: green means operational, red means the module has reached end-of-life and must be replaced. In regions with 50 or more thunderstorm days per year, expect module replacement every 3 to 5 years on average.\r\n<h2>Related Resources<\/h2>\r\n<h3>Existing Blog Articles on Britec Electric<\/h3>\r\n<ul>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">Oversp\u00e6ndingsbeskyttelsesenhed Oversigt<\/a> \u2014 Comprehensive guide to Type 1, Type 2, and Type 3 SPDs, their test waveforms, and installation positions.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/blog\/ac-spd-single-phase-coordination-circuit-breakers\/\" target=\"_blank\" rel=\"noopener\">AC SPD Single Phase Coordination with Circuit Breakers<\/a> \u2014 Technical guide to SCPD selection, MCB curve types, and cascade coordination for single-phase SPD installations.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/blog\/surge-protection-for-photovoltaic-systems\/\" target=\"_blank\" rel=\"noopener\">Surge Protection for Photovoltaic Systems<\/a> \u2014 Lightning protection strategies for solar PV installations in thunderstorm-prone regions.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/blog\/surge-protector-for-led-lighting\/\" target=\"_blank\" rel=\"noopener\">Surge Protector for LED Lighting<\/a> \u2014 SPD selection for outdoor LED lighting systems exposed to indirect lightning surges.<\/li>\r\n<\/ul>\r\n<h3>Relevant Product Pages<\/h3>\r\n<ul>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-1p-type-1-25ka-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1P Type 1 25kA oversp\u00e6ndingsafleder<\/a> \u2014 Single-pole Type 1+2+3 SPD for TN-S and TN-C-S systems<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1+1 Type 1 25kA Surge Arrester for TT and TN-S<\/a> \u2014 1P+N configuration for TT earthing systems<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/product\/brscb-i-25-class-i-25ka-dedicated-backup-protector\/\" target=\"_blank\" rel=\"noopener\">BRSCB-I-25 Class I 25kA Dedicated Backup Protector<\/a> \u2014 Specially engineered SCPD for Type 1 SPD coordination<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/product\/brci-coordination-inductor\/\" target=\"_blank\" rel=\"noopener\">BRCI Coordination Inductor<\/a> \u2014 Decoupling inductor for Type 1 \u2014 Type 2 cascade coordination under 10 metres<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/product\/brcb-15-30-40-type-2-surge-protection-device-combined-with-mini-circuit-breaker\/\" target=\"_blank\" rel=\"noopener\">BRCB-15\/30\/40 Type 2 SPD Combined with MCB<\/a> \u2014 All-in-one Type 2 SPD + backup protector for sub-distribution boards<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/da\/\" target=\"_blank\" rel=\"noopener\">Britec Electric Homepage<\/a> \u2014 Full product catalogue and company information<\/li>\r\n<\/ul>","protected":false},"featured_media":2547,"parent":0,"menu_order":58,"template":"","meta":{"_acf_changed":false},"blog_category":[9],"class_list":["post-2551","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-industry-news"],"acf":{"des":"Discover when a Type 1 SPD is mandatory in lightning-prone regions. Learn IEC 62305 requirements, keraunic levels, Iimp ratings, and cascade coordination to protect your facility.","txt":"If your facility is located in a region with frequent thunderstorms, the question is not whether you need surge protection, but whether a standard Type 2 SPD is sufficient or whether a <strong>Type 1 surge protection device<\/strong> is required at the service entrance. The answer depends on three factors defined by <strong>IEC 62305<\/strong> and <strong>IEC 61643-11<\/strong>: whether your building has an external lightning protection system, whether power is supplied via overhead lines, and the local lightning density (keraunic level). This guide explains exactly when a Type 1 SPD is mandatory, what happens if you install the wrong type, and how to select the right configuration for your installation. For an overview of all SPD types, see our <a href=\"https:\/\/www.britecelectric.com\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">surge protection device overview<\/a>.\r\n<div style=\"background: #f0f8f8; border-left: 4px solid #009292; padding: 20px 24px; margin: 24px 0; border-radius: 0 8px 8px 0;\">\r\n<p style=\"font-size: 18px; font-weight: bold; color: #009292; margin: 0 0 8px 0;\">Protect Your Facility From Direct Lightning Current<\/p>\r\n<p style=\"font-size: 14px; color: #444; line-height: 1.6; margin: 0 0 16px 0;\">Britec Electric manufactures IEC 61643-11 certified Type 1 SPDs rated at Iimp 25kA (10\/350\u00b5s), engineered for installations in high-lightning regions worldwide. Our BR-25M series handles partial lightning current at the service entrance, protecting your downstream equipment and Type 2 SPDs from catastrophic failure.<\/p>\r\n<a style=\"display: inline-block; background: #009292; color: #fff; font-size: 15px; font-weight: bold; padding: 12px 32px; border-radius: 6px; text-decoration: none;\" href=\"https:\/\/www.britecelectric.com\/contact-us\" target=\"_blank\" rel=\"noopener\">Request a Free Quote<\/a>\r\n\r\n<\/div>\r\n<h2>What Makes a Region \"Lightning-Prone\"?<\/h2>\r\nLightning activity varies dramatically across the globe. The <strong>keraunic level<\/strong> (also called thunderstorm days, Td) is the traditional metric: the average number of days per year on which thunder is heard at a given location. According to data from NASA and Vaisala, the global distribution ranges from near zero in polar regions to over 200 days per year in the tropics.\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0; font-size: 14px;\">\r\n<thead>\r\n<tr style=\"background: #009292; color: #fff;\">\r\n<th style=\"padding: 10px 12px; text-align: left; border: 1px solid #007a7a;\">Region \/ Country<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Keraunic Level (Td)<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Lightning Density (flashes\/km\u00b2\/yr)<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Type 1 SPD Recommendation<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Central Africa (DRC, Cameroon)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">150\u2013200+<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">50\u2013205<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Southeast Asia (Singapore, Malaysia, Indonesia)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">150\u2013180<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">20\u201380<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Florida, USA (\"Lightning Alley\")<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80\u2013100<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">9\u201324<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Northern Australia (Darwin)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u201330<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Central Europe (Germany, Austria, Switzerland)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u201335<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">2\u20135<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Risk assessment required<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">South America (Brazil, Colombia, Venezuela)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">80\u2013297 (Lake Maracaibo)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">15\u2013233<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd; color: #009292; font-weight: bold;\">Mandatory<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nAs a practical rule, when the keraunic level exceeds <strong>25 thunderstorm days per year<\/strong>, a formal <a href=\"https:\/\/www.britecelectric.com\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">lightning risk assessment<\/a> per IEC 62305-2 should be conducted. In regions above 50 Td, a Type 1 SPD at the service entrance is recommended as a baseline, even before completing the full risk calculation.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-31-type-1-25ka-surge-arrester-for-tt-and-tns\/\"><img class=\"alignnone size-full wp-image-2428\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-31-4.jpg\" alt=\"BR-25M 3+1 Type 1 25kA Surge Arrester For TT And TNS\" width=\"800\" \/><\/a>\r\n<h2>When Is a Type 1 SPD Mandatory?<\/h2>\r\nAccording to <strong>IEC 60364-5-53<\/strong> and <strong>IEC 62305-4<\/strong>, a Type 1 SPD is mandatory at the main distribution board (LPZ 0 \u2192 LPZ 1 boundary) under two specific conditions:\r\n<h3>1. The Building Has an External Lightning Protection System (LPS)<\/h3>\r\nWhen a building is equipped with an external lightning protection system comprising air terminals (lightning rods), down conductors, and an earth termination network per IEC 62305-3, a direct lightning strike to the air terminal will inject partial lightning current into the building's electrical system through the common earthing network. This partial current has the 10\/350 microsecond waveform and can reach tens of kiloamperes. Only a Type 1 SPD certified to IEC 61643-11 Class I can safely discharge this energy to earth without catastrophic failure.\r\n<h3>2. The Building Is Supplied by Overhead Power Lines<\/h3>\r\nOverhead power lines are directly exposed to lightning. A direct strike to the line, or a nearby strike that induces surge current through electromagnetic coupling, can propagate the 10\/350 microsecond lightning waveform into the building's main distribution board. IEC 60364-5-53 requires a Type 1 SPD at or near the origin of the electrical installation whenever overhead supply lines are present, regardless of whether the building itself has an external LPS.\r\n<div style=\"background: #fff8e1; border-left: 4px solid #f9a825; padding: 16px 20px; margin: 20px 0; border-radius: 0 6px 6px 0;\">\r\n<p style=\"font-size: 14px; color: #555; line-height: 1.6; margin: 0;\"><strong>Key distinction:<\/strong> A building with underground supply and no external LPS may be protected by a Type 2 SPD at the MDB, subject to risk assessment. However, in high-keraunic regions, even underground cables can carry induced lightning current through ground potential rise, making a combined Type 1+2 SPD the safer engineering choice.<\/p>\r\n\r\n<\/div>\r\n<h2>Why Type 2 SPDs Cannot Substitute for Type 1<\/h2>\r\nThe critical technical difference between Type 1 and Type 2 SPDs is the <strong>test waveform<\/strong>. IEC 61643-11 defines:\r\n<ul>\r\n \t<li><strong>Type 1 (Class I):<\/strong> Tested with 10\/350\u00b5s lightning impulse current (Iimp). This waveform simulates partial direct lightning current. At 25kA peak, the 10\/350\u00b5s impulse carries a specific energy (W\/R) of approximately 156 kJ\/\u03a9.<\/li>\r\n \t<li><strong>Type 2 (Class II):<\/strong> Tested with 8\/20\u00b5s nominal discharge current (In). This waveform simulates switching surges and induced lightning surges. At 20kA peak, the 8\/20\u00b5s impulse carries only about 7.4 kJ\/\u03a9 of specific energy.<\/li>\r\n<\/ul>\r\nAt the same peak current, the 10\/350\u00b5s waveform delivers <strong>10 to 20 times more total energy<\/strong> than the 8\/20\u00b5s waveform because of its long duration tail (350 microseconds vs 20 microseconds at the half-value point). When a Type 2 SPD is subjected to 10\/350\u00b5s current, its MOV elements absorb energy far exceeding their thermal rating, resulting in:\r\n<ul>\r\n \t<li>Immediate MOV rupture or shattering<\/li>\r\n \t<li>Housing deformation or fire<\/li>\r\n \t<li>Loss of protection at the exact moment the lightning strike occurs<\/li>\r\n \t<li>Potential short-circuit from line to earth, tripping upstream protection and disconnecting the entire installation<\/li>\r\n<\/ul>\r\nThis is why IEC 61643-11 and IEC 62305-4 strictly prohibit substituting a Type 2 SPD for a Type 1 SPD at the LPZ 0 \u2192 LPZ 1 boundary.\r\n\r\n<a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\"><img class=\"alignnone size-full wp-image-2430\" src=\"https:\/\/www.britecelectric.com\/wp-content\/uploads\/2024\/09\/BR-25M-11-3.jpg\" alt=\"BR-25M 1+1 Type 1 25kA Surge Arrester For TT And TNS\" width=\"800\" \/><\/a>\r\n\r\n&nbsp;\r\n<h2>Type 1 SPD Product Selection for Lightning-Prone Regions<\/h2>\r\nThe <a href=\"https:\/\/www.britecelectric.com\/\" target=\"_blank\" rel=\"noopener\">Britec Electric<\/a> BR-25M series is engineered for installations in lightning-prone regions. These SPDs are classified as Type 1+2+3 combined devices, certified to IEC 61643-11 and EN 61643-11, with an Iimp of 25kA (10\/350\u00b5s) and Imax of 120kA (8\/20\u00b5s).\r\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0; font-size: 14px;\">\r\n<thead>\r\n<tr style=\"background: #009292; color: #fff;\">\r\n<th style=\"padding: 10px 12px; text-align: left; border: 1px solid #007a7a;\">Parameter<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">BR-25M 1P<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">BR-25M 1+1<\/th>\r\n<th style=\"padding: 10px 12px; text-align: center; border: 1px solid #007a7a;\">Application<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">SPD Type (IEC 61643-11)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Class I + II + III<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">Class I + II + III<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Service entrance, LPZ 0\u21921<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Iimp (10\/350\u00b5s)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">25kA<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">25kA (L-N) \/ 50kA (N-PE)<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Partial lightning current<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Imax (8\/20\u00b5s)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">120kA<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">120kA<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Switching surges<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Uc (275V variant)<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">275V<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">275V \/ 255V<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">230\/400V systems<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Up<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">\u22641.3kV<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">\u22641.3kV \/ \u22641.5kV<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Below Category IV Uw<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f9f9f9;\">\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Earthing system<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">TN-S, TN-C-S<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">TT, TN-S<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Match to installation<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">Max backup fuse<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">200A gG<\/td>\r\n<td style=\"padding: 10px 12px; text-align: center; border: 1px solid #ddd;\">200A gG<\/td>\r\n<td style=\"padding: 10px 12px; border: 1px solid #ddd;\">SCPD coordination<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nFor single-phase TN-S systems, the <a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-1p-type-1-25ka-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1P Type 1 25kA surge arrester<\/a> provides single-pole L-PE protection. For TT systems or TN-S systems with transformer-side neutral earthing, the <a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1+1 Type 1 25kA for TT and TN-S<\/a> provides the L-N + N-PE configuration required by IEC 60364-5-53.\r\n<h2>Cascade Coordination: Type 1 + Type 2 Strategy<\/h2>\r\nInstalling a Type 1 SPD alone is not a complete protection strategy. IEC 62305-4 defines a <strong>coordinated SPD system<\/strong> where multiple SPD types are installed at successive LPZ boundaries to progressively reduce surge voltage to levels that sensitive equipment can withstand.\r\n\r\nThe standard cascade for lightning-prone regions is:\r\n<ul>\r\n \t<li><strong>LPZ 0 \u2192 LPZ 1 (main distribution board):<\/strong> Type 1 SPD with Iimp \u2265 25kA. Discharges partial lightning current to earth. Up \u2264 1.5kV.<\/li>\r\n \t<li><strong>LPZ 1 \u2192 LPZ 2 (sub-distribution board):<\/strong> Type 2 SPD with In \u2265 20kA. Further reduces residual surge voltage. Up \u2264 1.4kV.<\/li>\r\n \t<li><strong>LPZ 2 \u2192 LPZ 3 (equipment terminal):<\/strong> Type 3 SPD with Uoc \u2264 10kV. Fine protection for sensitive electronics. Up \u2264 1.0kV.<\/li>\r\n<\/ul>\r\nWhen a Type 1 and Type 2 SPD are installed in the same system, they must be separated by at least <strong>10 metres of cable<\/strong> between their installation points. If the physical distance is less than 10 metres, install a decoupling <a href=\"https:\/\/www.britecelectric.com\/product\/brci-coordination-inductor\/\" target=\"_blank\" rel=\"noopener\">coordination inductor<\/a> between the two positions, or use a combined Type 1+2 device. For detailed guidance on SPD-to-circuit-breaker coordination, see our article on <a href=\"https:\/\/www.britecelectric.com\/blog\/ac-spd-single-phase-coordination-circuit-breakers\/\" target=\"_blank\" rel=\"noopener\">AC SPD single phase coordination with circuit breakers<\/a>.\r\n<h2>Backup Protection for Type 1 SPDs<\/h2>\r\nEvery Type 1 SPD must have an upstream short-circuit protective device (SCPD) to safely disconnect the SPD when its internal MOV reaches end-of-life and fails in short-circuit mode. For the BR-25M series with Iimp 25kA, the maximum permitted backup fuse is <strong>200A gG<\/strong>.\r\n\r\nWhile standard gG fuses or Type C\/D MCBs can serve as the SCPD, dedicated SPD backup protectors offer superior coordination. The <a href=\"https:\/\/www.britecelectric.com\/product\/brscb-i-25-class-i-25ka-dedicated-backup-protector\/\" target=\"_blank\" rel=\"noopener\">BRSCB-I-25 Class I 25kA dedicated backup protector<\/a> is specifically engineered for Type 1 SPD coordination:\r\n<ul>\r\n \t<li>Withstands 25kA at 10\/350\u00b5s without nuisance tripping<\/li>\r\n \t<li>Cuts leakage current to under 3A when the SPD fails<\/li>\r\n \t<li>Available in 1P, 2P, 3P, and 4P configurations<\/li>\r\n \t<li>Visual status indicator: green (normal) \/ red (fault)<\/li>\r\n<\/ul>\r\nFor installations using a combined Type 2 SPD with integrated MCB, the <a href=\"https:\/\/www.britecelectric.com\/product\/brcb-15-30-40-type-2-surge-protection-device-combined-with-mini-circuit-breaker\/\" target=\"_blank\" rel=\"noopener\">BRCB-15\/30\/40 Type 2 SPD combined with MCB<\/a> provides a compact all-in-one solution for sub-distribution boards.\r\n<h2>Common Mistakes in Lightning-Prone Region Installations<\/h2>\r\n<h3>Mistake 1: Relying on Type 2 Alone<\/h3>\r\nThe most dangerous and common mistake. In buildings with external LPS or overhead supply, a Type 2 SPD at the service entrance will fail catastrophically during the first significant lightning event, leaving all downstream equipment unprotected.\r\n<h3>Mistake 2: Ignoring the Keraunic Level<\/h3>\r\nMany specifiers use the same SPD specification across all project locations. A design adequate for Central Europe (Td 15\u201335) is insufficient for a project in Southeast Asia (Td 150+). Always check the local keraunic level and conduct an IEC 62305-2 risk assessment.\r\n<h3>Mistake 3: Mismatched Earthing System and SPD Configuration<\/h3>\r\nInstalling a 1P SPD in a TT system, or a 1+1 SPD in a TN-C system, creates protection gaps. Verify the earthing system with a qualified electrician before selecting the SPD pole configuration.\r\n<h3>Mistake 4: Excessive Lead Length<\/h3>\r\nIEC 61643-12 requires total SPD lead length (busbar \u2192 SPD \u2192 PE bar) not to exceed 0.5 metres. Every extra metre adds approximately 1\u00b5H of inductance, which at 10kA\/\u00b5s di\/dt adds 10kV of residual voltage, completely negating the SPD's clamping performance.\r\n<h3>Mistake 5: No Annual Inspection Programme<\/h3>\r\nSPDs are sacrificial devices. In high-lightning regions, a Type 1 SPD may reach end-of-life within 3\u20135 years. Without annual visual inspection of the green\/red status indicator, a failed SPD can sit unnoticed for years, providing zero protection.\r\n<h3>Mistake 6: Skipping the Coordination Inductor<\/h3>\r\nWhen Type 1 and Type 2 SPDs are installed less than 10 metres apart without a coordination inductor, the faster-responding Type 2 activates first and absorbs more energy than its rating allows, causing premature failure.\r\n<div style=\"background: #f0f8f8; border-left: 4px solid #009292; padding: 20px 24px; margin: 24px 0; border-radius: 0 8px 8px 0;\">\r\n<p style=\"font-size: 18px; font-weight: bold; color: #009292; margin: 0 0 8px 0;\">Get Expert Guidance on Your Lightning Protection Strategy<\/p>\r\n<p style=\"font-size: 14px; color: #444; line-height: 1.6; margin: 0 0 16px 0;\">Not sure which Type 1 SPD configuration your project needs? Our engineering team helps B2B clients worldwide select the right IEC 61643-11 certified SPDs based on local keraunic levels, earthing systems, and cascade coordination requirements. We also provide dedicated backup protectors and coordination inductors for complete system protection.<\/p>\r\n<a style=\"display: inline-block; background: linear-gradient(135deg, #009292, #00b3b3); color: #fff; font-size: 15px; font-weight: bold; padding: 12px 32px; border-radius: 6px; text-decoration: none;\" href=\"https:\/\/www.britecelectric.com\/contact-us\/\" target=\"_blank\" rel=\"noopener\">Get a Free Quote Now<\/a>\r\n\r\n<\/div>\r\n<h2>Frequently Asked Questions<\/h2>\r\n<h3>1. When is a Type 1 SPD mandatory?<\/h3>\r\nA Type 1 SPD is mandatory in two scenarios defined by IEC 60364-5-53 and IEC 62305-4: first, when the building has an external lightning protection system (LPS) with air terminals, down conductors, and an earth termination system; second, when the building is supplied by overhead power lines that can carry direct or nearby lightning strikes into the electrical installation. In both cases, partial lightning current with the 10\/350 microsecond waveform can enter the building's main distribution board, and only a Type 1 SPD tested to IEC 61643-11 Class I can safely discharge this energy.\r\n<h3>2. What is the difference between Type 1 and Type 2 SPD?<\/h3>\r\nThe fundamental difference is the test waveform. Type 1 SPDs are tested with the 10\/350 microsecond lightning impulse current (Iimp), which simulates partial direct lightning current and carries 10 to 20 times more total energy than the 8\/20 microsecond waveform used for Type 2 SPDs. Type 1 SPDs install at the LPZ 0 to 1 boundary (main distribution board) to handle lightning current entering the building. Type 2 SPDs install at the LPZ 1 to 2 boundary (sub-distribution boards) to handle switching surges and residual lightning energy. A Type 2 SPD cannot substitute for a Type 1 SPD where Type 1 is required.\r\n<h3>3. What keraunic level requires Type 1 surge protection?<\/h3>\r\nThere is no single keraunic threshold that automatically mandates a Type 1 SPD, but IEC 62305-2 risk assessment becomes critical when the keraunic level (thunderstorm days per year) exceeds 25. Regions with keraunic levels above 50, such as Florida (80\u2013100 thunderstorm days), Singapore (180 days), and Central Africa (150\u2013200 days), have a high probability of direct or nearby lightning strikes. In these regions, if the building has an external LPS or is supplied by overhead lines, Type 1 SPD installation is effectively mandatory.\r\n<h3>4. Can a Type 2 SPD handle lightning current?<\/h3>\r\nNo. A Type 2 SPD is tested with the 8\/20 microsecond waveform at a nominal discharge current (In) of up to 20kA. The 10\/350 microsecond lightning waveform carries significantly more energy because of its long duration tail. When a Type 2 SPD is subjected to 10\/350 microsecond current, the MOV elements absorb 10 to 20 times their rated thermal energy, causing immediate catastrophic failure at the exact moment protection is needed most.\r\n<h3>5. What is Iimp and why does it matter for lightning-prone regions?<\/h3>\r\nIimp (impulse current) is the peak current value of the 10\/350 microsecond test waveform used to certify Type 1 SPDs per IEC 61643-11. It represents the partial lightning current that the SPD must safely discharge to earth. For residential and small commercial installations in lightning-prone regions, Iimp of 12.5kA per pole is the minimum acceptable value. For buildings with external lightning protection systems, IEC 62305-4 typically requires Iimp of at least 25kA per pole at the service entrance.\r\n<h3>6. Do I need a Type 1 SPD if my building has no lightning rod?<\/h3>\r\nIf your building has no external lightning protection system (LPS) and is supplied exclusively by underground cables, a Type 1 SPD is not strictly mandatory under IEC 60364-5-53. However, in lightning-prone regions with high keraunic levels, a risk assessment per IEC 62305-2 may still recommend a combined Type 1+2 SPD at the main distribution board, because nearby strikes can induce surge currents into underground cables through ground potential rise.\r\n<h3>7. How do I choose between 1P and 1+1 Type 1 SPD configurations?<\/h3>\r\nA 1P (single-pole) Type 1 SPD connects between line and protective earth (L-PE) and is used in TN-S and TN-C-S earthing systems. A 1+1 (1P+N) configuration consists of two modules: one between line and neutral (L-N) and one between neutral and earth (N-PE). The 1+1 configuration is required for TT earthing systems and for TN-S systems where the neutral-earth bond is at the transformer. Always match the SPD configuration to your earthing system as verified by a qualified electrician.\r\n<h3>8. What backup protection does a Type 1 SPD need?<\/h3>\r\nEvery Type 1 SPD requires an upstream short-circuit protective device (SCPD) to safely disconnect the SPD if its internal MOV fails in short-circuit mode. For Type 1 SPDs with Iimp of 25kA, the maximum permitted backup fuse is typically 200A gG. Dedicated SPD backup protectors such as the Britec BRSCB-I-25 are engineered specifically for lightning impulse coordination, cutting leakage current to under 3A and withstanding 25kA at 10\/350 microseconds without nuisance tripping.\r\n<h3>9. What happens if I only install a Type 2 SPD in a lightning-prone area?<\/h3>\r\nInstalling only a Type 2 SPD where a Type 1 is required creates a dangerous false sense of security. When lightning current with the 10\/350 microsecond waveform enters the installation, the Type 2 SPD will attempt to absorb energy far exceeding its rating. The result is immediate catastrophic failure: the MOV elements can shatter, the SPD housing can rupture, and the protected equipment is left exposed to the full lightning impulse. The cost of upgrading from Type 2 to Type 1+2 is minimal compared to the cost of equipment damage and downtime after a strike.\r\n<h3>10. How often should Type 1 SPDs be inspected or replaced in high-lightning areas?<\/h3>\r\nIn lightning-prone regions, Type 1 SPDs should be inspected at least once per year, and immediately after any known direct lightning strike to the building or nearby utility infrastructure. SPDs are sacrificial devices that degrade with each surge event. The thermal disconnection indicator window should be checked visually: green means operational, red means the module has reached end-of-life and must be replaced. In regions with 50 or more thunderstorm days per year, expect module replacement every 3 to 5 years on average.\r\n<h2>Related Resources<\/h2>\r\n<h3>Existing Blog Articles on Britec Electric<\/h3>\r\n<ul>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/blog\/surge-protection-device-overview\/\" target=\"_blank\" rel=\"noopener\">Surge Protection Device Overview<\/a> \u2014 Comprehensive guide to Type 1, Type 2, and Type 3 SPDs, their test waveforms, and installation positions.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/blog\/ac-spd-single-phase-coordination-circuit-breakers\/\" target=\"_blank\" rel=\"noopener\">AC SPD Single Phase Coordination with Circuit Breakers<\/a> \u2014 Technical guide to SCPD selection, MCB curve types, and cascade coordination for single-phase SPD installations.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/blog\/surge-protection-for-photovoltaic-systems\/\" target=\"_blank\" rel=\"noopener\">Surge Protection for Photovoltaic Systems<\/a> \u2014 Lightning protection strategies for solar PV installations in thunderstorm-prone regions.<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/blog\/surge-protector-for-led-lighting\/\" target=\"_blank\" rel=\"noopener\">Surge Protector for LED Lighting<\/a> \u2014 SPD selection for outdoor LED lighting systems exposed to indirect lightning surges.<\/li>\r\n<\/ul>\r\n<h3>Relevant Product Pages<\/h3>\r\n<ul>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-1p-type-1-25ka-surge-arrester\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1P Type 1 25kA Surge Arrester<\/a> \u2014 Single-pole Type 1+2+3 SPD for TN-S and TN-C-S systems<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/product\/br-25m-11-type-1-25ka-surge-arrester-for-tt-and-tns\/\" target=\"_blank\" rel=\"noopener\">BR-25M 1+1 Type 1 25kA Surge Arrester for TT and TN-S<\/a> \u2014 1P+N configuration for TT earthing systems<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/product\/brscb-i-25-class-i-25ka-dedicated-backup-protector\/\" target=\"_blank\" rel=\"noopener\">BRSCB-I-25 Class I 25kA Dedicated Backup Protector<\/a> \u2014 Specially engineered SCPD for Type 1 SPD coordination<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/product\/brci-coordination-inductor\/\" target=\"_blank\" rel=\"noopener\">BRCI Coordination Inductor<\/a> \u2014 Decoupling inductor for Type 1 \u2014 Type 2 cascade coordination under 10 metres<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/product\/brcb-15-30-40-type-2-surge-protection-device-combined-with-mini-circuit-breaker\/\" target=\"_blank\" rel=\"noopener\">BRCB-15\/30\/40 Type 2 SPD Combined with MCB<\/a> \u2014 All-in-one Type 2 SPD + backup protector for sub-distribution boards<\/li>\r\n \t<li><a href=\"https:\/\/www.britecelectric.com\/\" target=\"_blank\" rel=\"noopener\">Britec Electric Homepage<\/a> \u2014 Full product catalogue and company information<\/li>\r\n<\/ul>"},"_links":{"self":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog\/2551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media\/2547"}],"wp:attachment":[{"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/media?parent=2551"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.britecelectric.com\/da\/wp-json\/wp\/v2\/blog_category?post=2551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}